메뉴 건너뛰기




Volumn 50, Issue 17, 2011, Pages 2719-2731

Optical polarimetry for noninvasive glucose sensing enabled by Sagnac interferometry

Author keywords

[No Author keywords available]

Indexed keywords

DRUG PRODUCTS; GLUCOSE; GYROSCOPES; INTERFEROMETERS; INTERFEROMETRY; POLARIMETERS; POLARIZATION;

EID: 79958832022     PISSN: 1559128X     EISSN: 15394522     Source Type: Journal    
DOI: 10.1364/AO.50.002719     Document Type: Article
Times cited : (26)

References (22)
  • 2
    • 0020077396 scopus 로고
    • Noninvasive glucose monitoring of the aqueous humor of the eye: Part I. Measurement of very small optical rotations
    • B. Rabinovitch, W. F. March, and R. L. Adams, "Noninvasive glucose monitoring of the aqueous humor of the eye: Part I. Measurement of very small optical rotations," Diabetes Care 5, 254-258 (1982). (Pubitemid 12117175)
    • (1982) Diabetes Care , vol.5 , Issue.3 , pp. 254-258
    • Rabinovitch, B.1    March, W.F.2    Adams, R.L.3
  • 3
    • 0020055939 scopus 로고
    • Noninvasive glucose monitoring of the aqueous humor of the eye: II. Animal studies and the scleral lens
    • W. F. March, B. Rabinovitch, and R. L. Adams, "Noninvasive glucose monitoring of the aqueous humor of the eye: Part II. Animal studies and the scleral lens," Diabetes Care 5, 259-265 (1982). (Pubitemid 12117176)
    • (1982) Diabetes Care , vol.5 , Issue.3 , pp. 259-265
    • March, W.F.1    Rabinovitch, B.2    Adams, R.L.3
  • 4
    • 0002276296 scopus 로고
    • The glucose content of aqueous humor in man
    • S. Pohjola, "The glucose content of aqueous humor in man," Acta Ophthalmol. 88, 1-80 (1966).
    • (1966) Acta Ophthalmol , vol.88 , pp. 1-80
    • Pohjola, S.1
  • 5
    • 0034944362 scopus 로고    scopus 로고
    • Measurement of the glucose transport time delay between the blood and aqueous humor of the eye for the eventual development of a noninvasive glucose sensor
    • DOI 10.1089/152091501300209552
    • B. D. Cameron, J. S. Baba, and G. L. Coté, "Measurement of the glucose transport time delay between the blood and aqueous humor of the eye for the eventual development of a noninvasive glucose sensor," Diabetes Technol. Ther. 3, 201-207 (2001). (Pubitemid 32651954)
    • (2001) Diabetes Technology and Therapeutics , vol.3 , Issue.2 , pp. 201-207
    • Cameron, B.D.1    Baba, J.S.2    Cote, G.L.3
  • 6
    • 0031543269 scopus 로고    scopus 로고
    • Noninvasive glucose sensing utilizing a digital closed-loop polarimetric approach
    • DOI 10.1109/10.649993
    • B. D. Cameron and G. L. Coté, "Noninvasive glucose sensing utilizing a digital closed-loop polarimetric approach," IEEE Trans. Biomed. Eng. 44, 1221-1227 (1997). (Pubitemid 27516411)
    • (1997) IEEE Transactions on Biomedical Engineering , vol.44 , Issue.12 , pp. 1221-1227
    • Cameron, B.D.1    Cote, G.L.2
  • 7
    • 0036629487 scopus 로고    scopus 로고
    • Effect of temperature, pH, and corneal birefringence on polarimetric glucose monitoring in the eye
    • J. S. Baba, B. D. Cameron, S. Theru, and G. L. Coté, "Effect of temperature, pH, and corneal birefringence on polarimetric glucose monitoring in the eye," J. Biomed. Opt. 7, 321-328 (2002).
    • (2002) J. Biomed. Opt , vol.7 , pp. 321-328
    • Baba, J.S.1    Cameron, B.D.2    Theru, S.3    Coté, G.L.4
  • 8
    • 73649131298 scopus 로고    scopus 로고
    • The in vitro study of pressure change on corneal birefringence
    • Z. Xiao, C. Wang, and Y. Hao, "The in vitro study of pressure change on corneal birefringence," Ophthal. Res. 43, 159-168 (2010).
    • (2010) Ophthal. Res , vol.43 , pp. 159-168
    • Xiao, Z.1    Wang, C.2    Hao, Y.3
  • 9
    • 33744931362 scopus 로고    scopus 로고
    • Development of a real-time corneal birefringence compensated glucose sensing polarimeter
    • DOI 10.1089/dia.2006.8.156
    • B. D. Cameron and H. Anumula, "Development of a real-time corneal birefringence compensated glucose sensing polarimeter," Diabetes Technol. Ther. 8, 156-164 (2006). (Pubitemid 43848038)
    • (2006) Diabetes Technology and Therapeutics , vol.8 , Issue.2 , pp. 156-164
    • Cameron, B.D.1    Anumula, H.2
  • 10
    • 36049056326 scopus 로고
    • Sagnac effect
    • E. J. Post, "Sagnac effect," Rev. Mod. Phys. 39, 475-493 (1967).
    • (1967) Rev. Mod. Phys , vol.39 , pp. 475-493
    • Post, E.J.1
  • 11
    • 0003770851 scopus 로고    scopus 로고
    • American Diabetes Association
    • American Diabetes Association, "Diabetes Statistics," http:// www.diabetes.org/diabetes-statistics.jsp.
    • Diabetes Statistics
  • 12
    • 12144287979 scopus 로고    scopus 로고
    • New optical scheme for a polarimetric-based glucose sensor
    • R. R. Ansari, S. Böckle, and L. Rovati, "New optical scheme for a polarimetric-based glucose sensor," J. Biomed. Opt. 9, 103-115 (2004).
    • (2004) J. Biomed. Opt , vol.9 , pp. 103-115
    • Ansari, R.R.1    Böckle, S.2    Rovati, L.3
  • 13
    • 0023070873 scopus 로고
    • Corneal polarization in the living human eye explained with a biaxial model
    • G. J. Van Blokland and S. C. Verhelst, "Corneal polarization in the living human eye explained with a biaxial model," J. Opt. Soc. Am. A 4, 82-90 (1987).
    • (1987) J. Opt. Soc. Am. A , vol.4 , pp. 82-90
    • Van Blokland, G.J.1    Verhelst, S.C.2
  • 15
    • 84950609221 scopus 로고
    • The mean shape of the human cornea
    • P. M. Kiely, G. Smith, and L. G. Carney, "The mean shape of the human cornea," J. Mod. Opt. 29, 1027-1040 (1982).
    • (1982) J. Mod. Opt , vol.29 , pp. 1027-1040
    • Kiely, P.M.1    Smith, G.2    Carney, L.G.3
  • 16
    • 0022105223 scopus 로고
    • Accommodationdependent model of the human eye with aspherics
    • R. Navarro, J. Santamaría, and J. Bescós, "Accommodationdependent model of the human eye with aspherics," J. Opt. Soc. Am. A 2, 1273-1280 (1985).
    • (1985) J. Opt. Soc. Am. A , vol.2 , pp. 1273-1280
    • Navarro, R.1    Santamaría, J.2    Bescós, J.3
  • 18
    • 0033624437 scopus 로고    scopus 로고
    • Optical glucose sensing in biological fluids: An overview
    • DOI 10.1117/1.429962
    • R. J. McNichols and G. L. Coté, "Optical glucose sensing in biological fluids: An overview," J. Biomed. Opt. 5, 5-16 (2000). (Pubitemid 30556694)
    • (2000) Journal of Biomedical Optics , vol.5 , Issue.1 , pp. 5-16
    • McNichols, R.J.1    Cote, G.L.2
  • 19
    • 33751159642 scopus 로고    scopus 로고
    • Generalized matrix equivalence theorem for polarization theory
    • S. N. Savenkov, V. V. Marienko, and E. A. Oberemok, "Generalized matrix equivalence theorem for polarization theory," Phys. Rev. E 74, 056607 (2006).
    • (2006) Phys. Rev. E , vol.74 , pp. 056607
    • Savenkov, S.N.1    Marienko, V.V.2    Oberemok, E.A.3
  • 20
    • 57749088244 scopus 로고    scopus 로고
    • Highaccuracy spectropolarimetric imaging using photoelastic modulator cameras with low-polarization coatings
    • Adelphi, Maryland, 19-21 June
    • A. B. Mahler, P. Smith, R. Chipman, and G. Smith, "Highaccuracy spectropolarimetric imaging using photoelastic modulator cameras with low-polarization coatings," presented at the NASA Science Technology Conference, Adelphi, Maryland, 19-21 June 2007.
    • (2007) Presented at the NASA Science Technology Conference
    • Mahler, A.B.1    Smith, P.2    Chipman, R.3    Smith, G.4
  • 21
    • 0018048820 scopus 로고
    • METHOD FOR MIXING THE SIGNAL AND IDLER BEAMS OF AN OPO IN CdSe AT THE CORRECT POLARISATIONS
    • D. Andreou, "A method for mixing the signal and idler beams of an OPO in CdSe at the correct polarisations," J. Phys. E 11, 1164-1165 (1978). (Pubitemid 9420947)
    • (1978) J Phys E Sci Instrum , vol.11 , Issue.12 , pp. 1164-1165
    • Andreou, D.1
  • 22
    • 77955600560 scopus 로고    scopus 로고
    • Function of an implanted tissue glucose sensor for more than 1 year in animals
    • D. A. Gough, L. S. Kumosa, T. L. Routh, J. T. Lin, and J. Y. Lucisano, "Function of an implanted tissue glucose sensor for more than 1 year in animals," Sci. Transl. Med. 28, 42ra53 (2010).
    • (2010) Sci. Transl. Med , vol.28
    • Gough, D.A.1    Kumosa, L.S.2    Routh, T.L.3    Lin, J.T.4    Lucisano, J.Y.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.