메뉴 건너뛰기




Volumn 38, Issue 6, 2011, Pages 3050-3061

An innovative iterative thresholding algorithm for tumour segmentation and volumetric quantification on SPECT images: Monte Carlo-based methodology and validation

Author keywords

Monte Carlo; segmentation; SPECT; thresholding

Indexed keywords

CALIBRATION; ERRORS; IMAGE SEGMENTATION; ITERATIVE METHODS; MATLAB; MONTE CARLO METHODS; PARTICLE BEAMS; PHANTOMS; POSITRON EMISSION TOMOGRAPHY; RESPIRATORY MECHANICS; TESTING; TUMORS;

EID: 79958827066     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3590359     Document Type: Article
Times cited : (13)

References (61)
  • 1
    • 38549169720 scopus 로고    scopus 로고
    • Positron Emission Tomography/Computed Tomography for Target Delineation in Head and Neck Cancers
    • DOI 10.1053/j.semnuclmed.2007.11.002, PII S0001299807001407
    • P. H. Ahn and M. K. Garg, Positron emission tomographycomputed tomography for target delineation in head and neck cancers., N. Seminucl. Med. 38, 141-148 (2008). 10.1053/j.semnuclmed.2007.11.002 (Pubitemid 351163195)
    • (2008) Seminars in Nuclear Medicine , vol.38 , Issue.2 , pp. 141-148
    • Ahn, P.H.1    Garg, M.K.2
  • 3
    • 34447255709 scopus 로고    scopus 로고
    • Current status of PET/CT for tumour volume definition in radiotherapy treatment planning for non-small cell lung cancer (NSCLC)
    • DOI 10.1016/j.lungcan.2007.03.020, PII S0169500207001882
    • C. Greco, K. Rosenzweig, G. L. Cascini, and O. Tamburrini, Current status of PETCT for tumour volume definition in radiotherapy treatment planning for non-small cell lung cancer (NSCLC)., Lung Cancer 57, 125-134 (2007). 10.1016/j.lungcan.2007.03.020 (Pubitemid 47043188)
    • (2007) Lung Cancer , vol.57 , Issue.2 , pp. 125-134
    • Greco, C.1    Rosenzweig, K.2    Cascini, G.L.3    Tamburrini, O.4
  • 5
    • 0036603787 scopus 로고    scopus 로고
    • Measurement of tumor volume by PET to evaluate prognosis in patients with advanced cervical cancer treated by radiation therapy
    • DOI 10.1016/S0360-3016(02)02705-0, PII S0360301602027050
    • T. R. Miller and P. W. Grigsby, Measurement of tumour volume by PET to evaluate prognosis in patients with advanced cervical cancer treated by radiation therapy., Int. J. Radiat. Oncol., Biol., Phys. 53, 353-359 (2002). 10.1016/S0360-3016(02)02705-0 (Pubitemid 34522101)
    • (2002) International Journal of Radiation Oncology Biology Physics , vol.53 , Issue.2 , pp. 353-359
    • Miller, T.R.1    Grigsby, P.W.2
  • 6
    • 58149280395 scopus 로고    scopus 로고
    • Biological imaging in radiation therapy: Role of positron emission tomography
    • 10.1088/0031-9155/54/1/R01
    • U. Nestle, W. Weber, M. Hentschel, and A. L. Grosu, Biological imaging in radiation therapy: Role of positron emission tomography., Phys. Med. Biol. 54, R1-R25 (2009). 10.1088/0031-9155/54/1/R01
    • (2009) Phys. Med. Biol. , vol.54
    • Nestle, U.1    Weber, W.2    Hentschel, M.3    Grosu, A.L.4
  • 7
    • 39149112240 scopus 로고    scopus 로고
    • The role of hybrid SPECT-CT in oncology: Current and emerging clinical applications
    • 10.1016/j.crad.2007.11.008
    • F. U. Chowdhury and A. F. Scarsbrook, The role of hybrid SPECT-CT in oncology: Current and emerging clinical applications., Clin. Radiol. 63, 241-251 (2008). 10.1016/j.crad.2007.11.008
    • (2008) Clin. Radiol. , vol.63 , pp. 241-251
    • Chowdhury, F.U.1    Scarsbrook, A.F.2
  • 10
    • 77449094020 scopus 로고    scopus 로고
    • Feasibility and efficacy of single photon emission computed tomography-based three-dimensional conformal radiotherapy for hepatocellular carcinoma 8 cm or more with portal vein tumor thrombus in combination with transcatheter arterial chemoembolization
    • 10.1016/j.ijrob2009.03.023
    • S. Shirai, M. Sato, K. Suwa, K. Kishi, C. Shimono, T. Sonomura, N. Kawai, H. Tanihata, H. Minamiguchi, and M. Nakai, Feasibility and efficacy of single photon emission computed tomography-based three-dimensional conformal radiotherapy for hepatocellular carcinoma 8 cm or more with portal vein tumor thrombus in combination with transcatheter arterial chemoembolization., Int. J. Radiat. Oncol., Biol., Phys. 76, 1037-1044 (2010). 10.1016/j.ijrobp.2009.03.023
    • (2010) Int. J. Radiat. Oncol., Biol., Phys. , vol.76 , pp. 1037-1044
    • Shirai, S.1    Sato, M.2    Suwa, K.3    Kishi, K.4    Shimono, C.5    Sonomura, T.6    Kawai, N.7    Tanihata, H.8    Minamiguchi, H.9    Nakai, M.10
  • 11
    • 59649126661 scopus 로고    scopus 로고
    • Single photon emission computed tomography-based three-dimensional conformal radiotherapy for hepatocellular carcinoma with portal vein tumor thrombus
    • 10.1016/j.ijrob2008.04.055
    • S. Shirai, M. Sato, K. Suwa, K. Kishi, C. Shimono, N. Kawai, H. Tanihata, H. Minamiguchi, and M. Nakai, Single photon emission computed tomography-based three-dimensional conformal radiotherapy for hepatocellular carcinoma with portal vein tumor thrombus., Int. J. Radiat. Oncol., Biol., Phys. 73, 824-831 (2009). 10.1016/j.ijrobp.2008.04.055
    • (2009) Int. J. Radiat. Oncol., Biol., Phys. , vol.73 , pp. 824-831
    • Shirai, S.1    Sato, M.2    Suwa, K.3    Kishi, K.4    Shimono, C.5    Kawai, N.6    Tanihata, H.7    Minamiguchi, H.8    Nakai, M.9
  • 12
    • 77950940764 scopus 로고    scopus 로고
    • Methodology to incorporate biologically effective dose and equivalent uniform dose in patient-specific 3-dimensional dosimetry for non-Hodgkin lymphoma patients targeted with 131I-tositumomab therapy
    • 10.2967/jnumed.109.067298
    • H. Amro, S. J. Wilderman, Y. K. Dewaraja, and P. L. Roberson, Methodology to incorporate biologically effective dose and equivalent uniform dose in patient-specific 3-dimensional dosimetry for non-Hodgkin lymphoma patients targeted with 131I-tositumomab therapy., J. Nucl. Med. 51, 654-659 (2010). 10.2967/jnumed.109.067298
    • (2010) J. Nucl. Med. , vol.51 , pp. 654-659
    • Amro, H.1    Wilderman, S.J.2    Dewaraja, Y.K.3    Roberson, P.L.4
  • 13
    • 34250345988 scopus 로고    scopus 로고
    • Three-dimensional radiobiologic dosimetry: Application of radiobiologic modeling to patient-specific 3-dimensional imaging-based internal dosimetry
    • DOI 10.2967/jnumed.106.038000
    • A. R. Prideaux, H. Song, R. F. Hobbs, B. He, E. C. Frey, P. W. Ladenson, R. L. Wahl, and G. Sgouros, Three-dimensional radiobiologic dosimetry: application of radiobiologic modeling to patient-specific 3-dimensional imaging-based internal dosimetry., J. Nucl. Med. 48, 1008-1016 (2007). 10.2967/jnumed.106.038000 (Pubitemid 46909931)
    • (2007) Journal of Nuclear Medicine , vol.48 , Issue.6 , pp. 1008-1016
    • Prideaux, A.R.1    Song, H.2    Hobbs, R.F.3    He, B.4    Frey, E.C.5    Ladenson, P.W.6    Wahl, R.L.7    Sgouros, G.8
  • 16
    • 70350704832 scopus 로고    scopus 로고
    • 124I PET-based 3D-RD dosimetry for a pediatric thyroid cancer patient: Real-time treatment planning and methodologic comparison
    • 10.2967/jnumed.109.066738
    • R. F. Hobbs, R. L. Wahl, M. A. Lodge, M. S. Javadi, S. Y. Cho, D. T. Chien, M. E. Ewertz, C. E. Esaias, P. W. Ladenson, and G. Sgouros, 124I PET-based 3D-RD dosimetry for a pediatric thyroid cancer patient: real-time treatment planning and methodologic comparison., J. Nucl. Med. 50, 1844-1847 (2009). 10.2967/jnumed.109.066738
    • (2009) J. Nucl. Med. , vol.50 , pp. 1844-1847
    • Hobbs, R.F.1    Wahl, R.L.2    Lodge, M.A.3    Javadi, M.S.4    Cho, S.Y.5    Chien, D.T.6    Ewertz, M.E.7    Esaias, C.E.8    Ladenson, P.W.9    Sgouros, G.10
  • 17
    • 70449716892 scopus 로고    scopus 로고
    • Patient specific treatment planning for systemically administered radiopharmaceuticals using PETCT and Monte Carlo simulation
    • 10.1016/j.apradiso.2009.09.070
    • J. J. Grudzinski, H. Yoriyaz, P. M. J. Delucar, and J. P. Weichert, Patient specific treatment planning for systemically administered radiopharmaceuticals using PETCT and Monte Carlo simulation., Appl. Radiat. Isot. 68, 59-65 (2010). 10.1016/j.apradiso.2009.09.070
    • (2010) Appl. Radiat. Isot. , vol.68 , pp. 59-65
    • Grudzinski, J.J.1    Yoriyaz, H.2    Delucar, P.M.J.3    Weichert, J.P.4
  • 18
    • 15844368087 scopus 로고    scopus 로고
    • Prognostic impact of hypoxia imaging with 18F-misonidazole PET in non-small cell lung cancer and head and neck cancer before radiotherapy
    • S. M. Eschmann, Prognostic impact of hypoxia imaging with 18F-misonidazole PET in non-small cell lung cancer and head and neck cancer before radiotherapy., J. Nucl. Med. 46, 253-260 (2005).
    • (2005) J. Nucl. Med. , vol.46 , pp. 253-260
    • Eschmann, S.M.1
  • 19
    • 46749127817 scopus 로고    scopus 로고
    • Tumor cell metabolism imaging
    • DOI 10.2967/jnumed.107.045930
    • C. Plathow and W. A. Weber. Tumor cell metabolism imaging., J. Nucl. Med. 49, 43S-63S (2008). 10.2967/jnumed.107.045930 (Pubitemid 351948036)
    • (2008) Journal of Nuclear Medicine , vol.49 , Issue.SUPPL.6
    • Plathow, C.1    Weber, W.A.2
  • 22
    • 67349238288 scopus 로고    scopus 로고
    • PETCT for the staging and follow-up of patients with malignancies
    • 10.1016/j.ejrad.2009.03.051
    • T. D. Poeppel, B. J. Krause, T. A. Heusner, C. Boy, A. Bockisch, and G. Antoch, PETCT for the staging and follow-up of patients with malignancies., Eur. J. Radiol. 3, 382-392 (2009). 10.1016/j.ejrad.2009.03.051
    • (2009) Eur. J. Radiol. , vol.3 , pp. 382-392
    • Poeppel, T.D.1    Krause, B.J.2    Heusner, T.A.3    Boy, C.4    Bockisch, A.5    Antoch, G.6
  • 24
    • 2342589401 scopus 로고    scopus 로고
    • 99mTc-sestamibi brain SPECT after chemoradiotherapy is prognostic of survival in patients with high-grade glioma
    • 99mTc- Sestamibi brain SPECT after chemoradiotherapy is prognostic of survival in patients with high-grade glioma., J. Nucl. Med. 45, 409-413 (2004). (Pubitemid 47618613)
    • (2004) Journal of Nuclear Medicine , vol.45 , Issue.3 , pp. 409-413
    • Beauchesne, P.1    Pedeux, R.2    Boniol, M.3    Soler, C.4
  • 32
  • 34
    • 0345303828 scopus 로고    scopus 로고
    • Tri-dimensional automatic segmentation of PET volumes based on measured source-to-background ratios: Influence of reconstruction algorithms
    • DOI 10.1016/S0167-8140(03)00270-6
    • J. F. Daisne, M. Sibomana, A. Bol, T. Doumont, M. Lonneux, and V. Gregoire, Tri-dimensional automatic segmentation of PET volumes based on measured source-to-background ratios: Influence of reconstruction algorithms., Radiother. Oncol. 69, 247-250 (2003). 10.1016/S0167-8140(03)00270-6 (Pubitemid 37485998)
    • (2003) Radiotherapy and Oncology , vol.69 , Issue.3 , pp. 247-250
    • Daisne, J.-F.1    Sibomana, M.2    Bol, A.3    Doumont, T.4    Lonneux, M.5    Gregoire, V.6
  • 39
    • 35448940983 scopus 로고    scopus 로고
    • 18F-Fluoro-Deoxy- Glucose-Positron Emission Tomography-Based Target VolumeDefinition in Head and Neck Cancer
    • DOI 10.1016/j.ijrobp.2007.07.2333, PII S0360301607036644
    • D. A. Schinagl, W. V. Vogel, A. L. Hoffmann, J. A. van Dalen, W. J. Oyen, and J. H. Kaanders, Comparison of five segmentation tools for 18F fluoro-deoxy-glucose-positron emission tomography-based target volume definition in head and neck cancer., Int. J. Radiat. Oncol., Biol., Phys. 69, 1282-1289 (2007). 10.1016/j.ijrobp.2007.07.2333 (Pubitemid 47625859)
    • (2007) International Journal of Radiation Oncology Biology Physics , vol.69 , Issue.4 , pp. 1282-1289
    • Schinagl, D.A.X.1    Vogel, W.V.2    Hoffmann, A.L.3    Van Dalen, J.A.4    Oyen, W.J.5    Kaanders, J.H.A.M.6
  • 41
    • 33846564887 scopus 로고    scopus 로고
    • Fully automated segmentation of oncological PET volumes using a combined multiscale and statistical model
    • DOI 10.1118/1.2432404
    • D. Montgomery, A. Amira, and H. Zaidi, Fully automated segmentation of oncological PET volumes using a combined multiscale and statistical model., Med. Phys. 34, 722-736 (2007). 10.1118/1.2432404 (Pubitemid 46185152)
    • (2007) Medical Physics , vol.34 , Issue.2 , pp. 722-736
    • Montgomery, D.W.G.1    Amira, A.2    Zaidi, H.3
  • 42
    • 58849127328 scopus 로고    scopus 로고
    • Assessment of various strategies for 18F-FET PET-guided delineation of target volumes in high-grade glioma patients
    • 10.1007/s00259-008-0943-6
    • H. Vees, Assessment of various strategies for 18F-FET PET-guided delineation of target volumes in high-grade glioma patients., Eur. J. Nucl. Med. Mol. Imaging 36, 182-193 (2009). 10.1007/s00259-008-0943-6
    • (2009) Eur. J. Nucl. Med. Mol. Imaging , vol.36 , pp. 182-193
    • Vees, H.1
  • 43
    • 33846821671 scopus 로고    scopus 로고
    • Correlation of PET standard uptake value and CT window-level thresholds for target delineation in CT-based radiation treatment planning
    • DOI 10.1016/j.ijrobp.2006.09.039, PII S0360301606031300
    • R. Hong, J. Halama, D. Bova, A. Sethi, and B. Emami, Correlation of PET standard uptake value and CT window-level thresholds for target delineation in CT-based radiation treatment planning., Int. J. Radiat. Oncol., Biol., Phys. 67, 720-726 (2007). 10.1016/j.ijrobp.2006.09.039 (Pubitemid 46215874)
    • (2007) International Journal of Radiation Oncology Biology Physics , vol.67 , Issue.3 , pp. 720-726
    • Hong, R.1    Halama, J.2    Bova, D.3    Sethi, A.4    Emami, B.5
  • 44
    • 16344394621 scopus 로고    scopus 로고
    • Comparison of CT- and FDG-PET-defined gross tumor volume in intensity-modulated radiotherapy for head-and-neck cancer
    • DOI 10.1016/j.ijrobp.2004.08.037
    • A. C. Paulino, M. Koshy, R. Howell, D. Schuster, and L. W. Davis. Comparison of CT- and FDG-PET-defined gross tumor volume in intensity-modulated radiotherapy for head-and-neck cancer., Int. J. Radiat. Oncol., Biol., Phys. 61, 1385-1392 (2005). 10.1016/j.ijrobp.2004.08.037 (Pubitemid 40470419)
    • (2005) International Journal of Radiation Oncology Biology Physics , vol.61 , Issue.5 , pp. 1385-1392
    • Paulino, A.C.1    Koshy, M.2    Howell, R.3    Schuster, D.4    Davis, L.W.5
  • 45
    • 18144366233 scopus 로고    scopus 로고
    • Threshold modification for tumour imaging in non-small-cell lung cancer using positron emission tomography
    • DOI 10.1097/00006231-200505000-00007
    • B. Yaremko, Threshold modification for tumour imaging in non-small-cell lung cancer using positron emission tomography., Nucl. Med. Commun. 26, 433-440 (2005). 10.1097/00006231-200505000-00007 (Pubitemid 40617732)
    • (2005) Nuclear Medicine Communications , vol.26 , Issue.5 , pp. 433-440
    • Yaremko, B.1    Riauka, T.2    Robinson, D.3    Murray, B.4    McEwan, A.5    Roa, W.6
  • 49
    • 4644240997 scopus 로고    scopus 로고
    • Tumor volume in pharyngolaryngeal squamous cell carcinoma: Comparison at CT, MR imaging, and FDG PET and validation with surgical specimen
    • DOI 10.1148/radiol.2331030660
    • J. F. Daisne, Tumor volume in pharyngolaryngeal squamous cell carcinoma: comparison at CT, MR imaging, and FDG PET and validation with surgical specimen., Radiology 233, 93-100 (2004). 10.1148/radiol.2331030660 (Pubitemid 39280962)
    • (2004) Radiology , vol.233 , Issue.1 , pp. 93-100
    • Daisne, J.-F.1    Duprez, T.2    Weynand, B.3    Lonneux, M.4    Hamoir, M.5    Reychler, H.6    Gregoire, V.7
  • 50
    • 41449113366 scopus 로고    scopus 로고
    • Threshold segmentation for PET target volume delineation in radiation treatment planning: The role of target-to-background ratio and target size
    • DOI 10.1118/1.2870215
    • M. Brambilla, R. Matheoud, C. Secco, G. Loi, M. Krengli, and E. Inglese, Threshold segmentation for PET target volume delineation in radiation treatment planning: The role of target-to-background ratio and target size., Med. Phys. 35, 1207-1213 (2008). 10.1118/1.2870215 (Pubitemid 351457486)
    • (2008) Medical Physics , vol.35 , Issue.4 , pp. 1207-1213
    • Brambilla, M.1    Matheoud, R.2    Secco, C.3    Loi, G.4    Krengli, M.5    Inglese, E.6
  • 51
    • 0024713937 scopus 로고
    • Monte Carlo program for the simulation of scintillation camera characteristics
    • DOI 10.1016/0169-2607(89)90111-9
    • M. Ljungberg and S. E. Strand. A C. Montearlo program for the simulation of scintillation camera characteristics., Comput. Methods Programs Biomed. 29, 257-272 (1989). 10.1016/0169-2607(89)90111-9 (Pubitemid 20610320)
    • (1989) Computer Methods and Programs in Biomedicine , vol.29 , Issue.4 , pp. 257-272
    • Michael, L.1    Sven-Erik, S.2
  • 52
    • 0028184981 scopus 로고
    • Preliminary experience with the photon history generator module for a public-domain simulation system for emission tomography
    • in (IEEE, F. Sanrancisco)
    • R. L. Harrison, Preliminary experience with the photon history generator module for a public-domain simulation system for emission tomography., in 1993 IEEE Conference Record in S. Nuclearcience Symposium and Medical Imaging Conference (IEEE, F. Sanrancisco 1994) pp. 1154-1158.
    • (1994) 1993 IEEE Conference Record in S. Nuclearcience Symposium and Medical Imaging Conference , pp. 1154-1158
    • Harrison, R.L.1
  • 53
    • 34250315240 scopus 로고    scopus 로고
    • Partial-volume effect in PET tumor imaging
    • DOI 10.2967/jnumed.106.035774
    • M. Soret, S. Bacharach L, and I. Buvat, Partial-volume effect in PET tumor imaging., J. Nucl. Med. 48, 932-945 (2007). 10.2967/jnumed.106.035774 (Pubitemid 46909922)
    • (2007) Journal of Nuclear Medicine , vol.48 , Issue.6 , pp. 932-945
    • Soret, M.1    Bacharach, S.L.2    Buvat, I.3
  • 54
    • 0017452940 scopus 로고
    • A method for attenuation correction in radionuclide computed tomography
    • 10.1109/TNS.1978.4329385
    • L. T. Chang, A method for attenuation correction in radionuclide computed tomography., IEEE Trans. Nucl. Sci. 25, 638-643 (1978). 10.1109/TNS.1978. 4329385
    • (1978) IEEE Trans. Nucl. Sci. , vol.25 , pp. 638-643
    • Chang, L.T.1
  • 55
    • 0032916211 scopus 로고    scopus 로고
    • Relevance of accurate Monte Carlo modeling in nuclear medical imaging
    • DOI 10.1118/1.598559
    • H. Zaidi, Relevance of accurate C. Montearlo modeling in nuclear medical imaging., Med. Phys. 26, 574-608 (1999). 10.1118/1.598559 (Pubitemid 29186278)
    • (1999) Medical Physics , vol.26 , Issue.4 , pp. 574-608
    • Zaidi, H.1
  • 58
    • 0028826667 scopus 로고
    • Threshold estimation in single photon emission computed tomography and planar imaging for clinical radioimmunotherapy
    • Y. E. Erdi, B. W. Wessels, M. H. Loew, and A. K. Erdi, Threshold estimation in single photon emission computed tomography and planar imaging for clinical radioimmunotherapy., Cancer Res. 55, 5823s-5826s (1995).
    • (1995) Cancer Res. , vol.55
    • Erdi, Y.E.1    Wessels, B.W.2    Loew, M.H.3    Erdi, A.K.4
  • 60
    • 41449113366 scopus 로고    scopus 로고
    • Threshold segmentation for PET target volume delineation in radiation treatment planning: The role of target-to-background ratio and target size
    • DOI 10.1118/1.2870215
    • M. Brambilla, R. Matheoud, C. Secco, G. Loi, M. Krengli, and E. Inglese, Threshold segmentation for PET target volume delineation in radiation treatment planning: The role of target-to-background ratio and target size., Med. Phys. 35, 1207-1213 (2008). 10.1118/1.2870215 (Pubitemid 351457486)
    • (2008) Medical Physics , vol.35 , Issue.4 , pp. 1207-1213
    • Brambilla, M.1    Matheoud, R.2    Secco, C.3    Loi, G.4    Krengli, M.5    Inglese, E.6
  • 61
    • 79952789282 scopus 로고    scopus 로고
    • Detection and characterization of tumor changes in 18F-FDG PET patient monitoring using parametric imaging
    • 10.2967/jnumed.110.080150
    • H. Necib, C. Garcia, A. Wagner, B. Vanderlinden, P. Emonts, A. Hendlisz, P. Flamen, and I. Buvat, Detection and characterization of tumor changes in 18F-FDG PET patient monitoring using parametric imaging., J. Nucl. Med. 52, 354-361 (2011). 10.2967/jnumed.110.080150
    • (2011) J. Nucl. Med. , vol.52 , pp. 354-361
    • Necib, H.1    Garcia, C.2    Wagner, A.3    Vanderlinden, B.4    Emonts, P.5    Hendlisz, A.6    Flamen, P.7    Buvat, I.8