-
1
-
-
33748649040
-
Transfixion wire positioning within the bone: An option to control proximal tibia external fixation stiffness
-
DOI 10.1097/01.bpo.0000226279.16449.8d, PII 0124139820060700000008
-
Antoci V, Raney EM, Antoci V Jr, Voor MJ, Roberts CS: Transfixion wire positioning within the bone: an option to control proximal tibia external fixation stiffness. J Pediatr Orthop 2006; 26(4):466-70. http://dx.doi.org/10. 1097/01.bpo.0000226279.16449.8d (Pubitemid 44384910)
-
(2006)
Journal of Pediatric Orthopaedics
, vol.26
, Issue.4
, pp. 466-470
-
-
Antoci, V.1
Raney, E.M.2
Antoci Jr., V.3
Voor, M.J.4
Roberts, C.S.5
-
2
-
-
33646018036
-
Experimental model of tibial plateau fracture for biomechanical testing
-
Ali AM, Saleh M, Bolongaro S, et al.: Experimental model of tibial plateau fracture for biomechanical testing. J Biomech 2006; 39:1355-60. http://dx.doi.org/10.1016/j.jbiomech.2005.03.022
-
(2006)
J Biomech
, vol.39
, pp. 1355-1360
-
-
Ali, A.M.1
Saleh, M.2
Bolongaro, S.3
-
3
-
-
0033073294
-
Early outcome of hybrid external fixation for fracture of the distal tibia
-
Anglen JO: Early outcome of hybrid external fixation for fracture of the distal tibia. J Orthop Trauma 1999;13:92-7. http://dx.doi.org/10.1097/00005131- 199902000-00004
-
(1999)
J Orthop Trauma
, vol.13
, pp. 92-97
-
-
Anglen, J.O.1
-
4
-
-
33947363301
-
Thermomechanical investigation of the cortical bone analogue in third-generation Sawbones femurs
-
Bell CG, Weinrauch P, Crawford R, et al.: Thermomechanical investigation of the cortical bone analogue in third-generation Sawbones femurs. Proc Inst Mech Eng [H] 2007; 221:213-7. http://dx.doi.org/10.1243/09544119JEIM191
-
(2007)
Proc Inst Mech Eng [H]
, vol.221
, pp. 213-217
-
-
Bell, C.G.1
Weinrauch, P.2
Crawford, R.3
-
5
-
-
0024519290
-
Pylon fractures of the distal tibia
-
Bourne, RB: Pylon fractures of the distal tibia. Clin Orthop Rel Res 1989:42-6.
-
(1989)
Clin Orthop Rel Res
, pp. 42-46
-
-
Bourne, R.B.1
-
6
-
-
0020566782
-
Intraarticular fractures of the distal tibia: The pilon fracture
-
Bourne, RB; Rorabeck, CH; McNabb, J: Intraarticular fractures of the distal tibia: the pilon fracture. J Trauma. 1983; 23:591-596. http://dx.doi.org/10.1097/00005373-198307000-00008
-
(1983)
J Trauma
, vol.23
, pp. 591-596
-
-
Bourne, R.B.1
Rorabeck, C.H.2
McNabb, J.3
-
7
-
-
0033622796
-
Mechanical validation of whole bone composite tibia models
-
Cristofolini, L; Viceconti, M: Mechanical validation of whole bone composite tibia models. J Biomech 2000; 33:279-88. http://dx.doi.org/10.1016/ S0021-9290(99)00186-4
-
(2000)
J Biomech
, vol.33
, pp. 279-288
-
-
Cristofolini, L.1
Viceconti, M.2
-
8
-
-
43049137358
-
Biomechanical strength of the Peri-Loc proximal tibial plate: A comparison of all-locked versus hybrid locked/nonlocked screw configurations
-
Estes, C; Rhee, P; Shrader, MW; et al.: Biomechanical strength of the Peri-Loc proximal tibial plate: a comparison of all-locked versus hybrid locked/nonlocked screw configurations. J Orthop Trauma 2008; 22:312-316. http://dx.doi.org/10.1097/BOT.0b013e31817279b8
-
(2008)
J Orthop Trauma
, vol.22
, pp. 312-316
-
-
Estes, C.1
Rhee, P.2
Shrader, M.W.3
-
9
-
-
34250861420
-
The line of action in the tibia during axial compression of the leg
-
Funk, JR; Rudd, RW; Kerrigan, JR; et al.: The line of action in the tibia during axial compression of the leg. J Biomech 2007; 40:2277-82. http://dx.doi.org/10.1016/j.jbiomech.2006.10.012
-
(2007)
J Biomech
, vol.40
, pp. 2277-2282
-
-
Funk, J.R.1
Rudd, R.W.2
Kerrigan, J.R.3
-
10
-
-
33847371691
-
Artificial composite bone as a model of human trabecular bone: The implant-bone interface
-
Grant, J; Bishop, N; Gotzen, N; et al.: Artificial composite bone as a model of human trabecular bone: The implant-bone interface. J Biomech 2007; 40(5):1158-64. http://dx.doi.org/10.1016/j.jbiomech.2006.04.007
-
(2007)
J Biomech
, vol.40
, Issue.5
, pp. 1158-1164
-
-
Grant, J.1
Bishop, N.2
Gotzen, N.3
-
11
-
-
0029787297
-
Tibial plafond fractures: Limited internal fixation and a hybrid external fixator
-
Griffiths, GP; Thordarson, DB: Tibial plafond fractures: limited internal fixation and a hybrid external fixator. Foot Ankle Int 1996; 17:444-8.
-
(1996)
Foot Ankle Int
, vol.17
, pp. 444-448
-
-
Griffiths, G.P.1
Thordarson, D.B.2
-
12
-
-
34548383874
-
Open reduction and internal fixation of tibial pilon fractures using a lateral approach
-
Grose, A; Gardner, MJ; Hettrich, C; et al.: Open reduction and internal fixation of tibial pilon fractures using a lateral approach. J Orthop Trauma 2007; 21:530-7. http://dx.doi.org/10.1097/BOT. 0b013e318145a227
-
(2007)
J Orthop Trauma
, vol.21
, pp. 530-537
-
-
Grose, A.1
Gardner, M.J.2
Hettrich, C.3
-
13
-
-
0034922981
-
Structural properties of a new design of composite replicate femurs and tibias
-
Heiner, A; Brown, T: Structural properties of a new design of composite replicate femurs and tibias. J Biomech 2001; 34(6):773-81. http://dx.doi.org/10. 1016/S0021-9290(01)00015-X
-
(2001)
J Biomech
, vol.34
, Issue.6
, pp. 773-781
-
-
Heiner, A.1
Brown, T.2
-
14
-
-
55549145079
-
Structural properties of fourth-generation composite femurs and tibias
-
Heiner, AD: Structural properties of fourth-generation composite femurs and tibias. J Biomech 2008; 41:3282-4. http://dx.doi.org/10. 1016/j.jbiomech.2008.08.013
-
(2008)
J Biomech
, vol.41
, pp. 3282-3284
-
-
Heiner, A.D.1
-
16
-
-
0031452816
-
Minimally invasive plate osteosynthesis of distal fractures of the tibia
-
discussion A47-8
-
Helfet, DL; Shonnard, PY; Levine, D; et al.: Minimally invasive plate osteosynthesis of distal fractures of the tibia. Injury 1997; 28 Suppl 1:A42-7; discussion A47-8.
-
(1997)
Injury
, vol.28
, Issue.SUPPL. 1
-
-
Helfet, D.L.1
Shonnard, P.Y.2
Levine, D.3
-
17
-
-
2342606058
-
Minimally invasive percutaneous plate osteosynthesis of fractures of the distal tibia
-
Helfet, DL; Suk, M: Minimally invasive percutaneous plate osteosynthesis of fractures of the distal tibia. Instr Course Lect 2004; 53:471-5.
-
(2004)
Instr Course Lect
, vol.53
, pp. 471-475
-
-
Helfet, D.L.1
Suk, M.2
-
18
-
-
0038035698
-
Effect of Fibular Plate Fixation on Rotational Stability of Simulated Distal Tibial Fractures Treated with Intramedullary Nailing
-
Kumar, A; Charlesbois, S; Cain, E; et al.: Effect of Fibular Plate Fixation on Rotational Stability of Simulated Distal Tibial Fractures Treated with Intramedullary Nailing. J Bone Joint Surg Am 2003; 85-A(4):604-8.
-
(2003)
J Bone Joint Surg Am
, vol.85 A
, Issue.4
, pp. 604-608
-
-
Kumar, A.1
Charlesbois, S.2
Cain, E.3
-
19
-
-
0028786121
-
Use of an articulated external fixator for fractures of the tibial plafond
-
Marsh, JL; Bonar, S; Nepola, JV; et al.: Use of an articulated external fixator for fractures of the tibial plafond. J Bone Joint Surg Am 1995; 77:1498-509.
-
(1995)
J Bone Joint Surg Am
, vol.77
, pp. 1498-1509
-
-
Marsh, J.L.1
Bonar, S.2
Nepola, J.V.3
-
21
-
-
0026438442
-
Complications encountered in the treatment of pilon fractures
-
McFerran, MA; Smith, SW; Boulas, HJ; et al.: Complications encountered in the treatment of pilon fractures. J Orthop Trauma 1992; 6:195-200. http://dx.doi.org/10.1097/00005131-199206000-00011
-
(1992)
J Orthop Trauma
, vol.6
, pp. 195-200
-
-
McFerran, M.A.1
Smith, S.W.2
Boulas, H.J.3
-
22
-
-
0033072103
-
A staged protocol for soft tissue management in the treatment of complex pilon fractures
-
Sirkin, M; Sanders, R; DiPasquale, T; et al.: A staged protocol for soft tissue management in the treatment of complex pilon fractures. J Orthop Trauma 1999; 13:78-84. http://dx.doi.org/10.1097/00005131-199902000-00002
-
(1999)
J Orthop Trauma
, vol.13
, pp. 78-84
-
-
Sirkin, M.1
Sanders, R.2
DiPasquale, T.3
-
23
-
-
38749093316
-
An update on the management of high-energy pilon fractures
-
Tarkin, IS; Clare, MP; Marcantonio, A; et al.: An update on the management of high-energy pilon fractures. Injury 2008; 39:142-54. http://dx.doi.org/10.1016/j.injury.2007.07.024
-
(2008)
Injury
, vol.39
, pp. 142-154
-
-
Tarkin, I.S.1
Clare, M.P.2
Marcantonio, A.3
-
24
-
-
0027272832
-
Open reduction and internal fixation of tibial plafond fractures. Variables contributing to poor results and complications
-
Teeny, SM; Wiss, DA: Open reduction and internal fixation of tibial plafond fractures. Variables contributing to poor results and complications. Clin Orthop Rel Res 1993:108-17.
-
(1993)
Clin Orthop Rel Res
, pp. 108-117
-
-
Teeny, S.M.1
Wiss, D.A.2
-
25
-
-
33748592806
-
Mechanical Contribution of the Fibula to Torsion Stiffness in the Lower Extremity
-
Thambyah, A; Pereira, B: Mechanical Contribution of the Fibula to Torsion Stiffness in the Lower Extremity. Clin Anat 2006; 19(7):615-20. http://dx.doi.org/10.1002/ca.20234
-
(2006)
Clin Anat
, vol.19
, Issue.7
, pp. 615-620
-
-
Thambyah, A.1
Pereira, B.2
-
26
-
-
0034223220
-
Complications after treatment of tibial pilon fractures: Prevention and management strategies
-
Thordarson, DB: Complications after treatment of tibial pilon fractures: prevention and management strategies. J Am Acad Orthop Surg 2000; 8:253-65.
-
(2000)
J Am Acad Orthop Surg
, vol.8
, pp. 253-265
-
-
Thordarson, D.B.1
-
27
-
-
0034096898
-
Pilon fractures. Treatment protocol based on severity of soft tissue injury
-
Watson, JT; Moed, BR; Karges, DE; et al.: Pilon fractures. Treatment protocol based on severity of soft tissue injury. Clin Orthop Rel Res 2000:78-90.
-
(2000)
Clin Orthop Rel Res
, pp. 78-90
-
-
Watson, J.T.1
Moed, B.R.2
Karges, D.E.3
-
28
-
-
34248222127
-
Cortical screw pullout strength and effective shear stress in synthetic third generation composite femurs
-
Zdero, R; Rose, S; Schemitsch, E; et al.: Cortical screw pullout strength and effective shear stress in synthetic third generation composite femurs. J Biomech 2007; 129(2):289-93.
-
(2007)
J Biomech
, vol.129
, Issue.2
, pp. 289-293
-
-
Zdero, R.1
Rose, S.2
Schemitsch, E.3
|