Initial stability of uncemented hip stems: an in-vitro protocol to measure torsional interface motion
Harman M.K., Toni A., Cristofolini L., and Viceconti M. Initial stability of uncemented hip stems: an in-vitro protocol to measure torsional interface motion. Medical Engineering & Physics 17 (1995) 163-171
Comparison of the stability of press-fit hip prosthesis femoral stems using a synthetic model femur
McKellop H., Ebramzadeh E., Niederer P.G., and Sarmiento A. Comparison of the stability of press-fit hip prosthesis femoral stems using a synthetic model femur. Journal of Orthopaedic Research 9 (1991) 297-305
Methods for quantitative analysis of the primary stability in uncemented hip prostheses
Monti L., Cristofolini L., and Viceconti M. Methods for quantitative analysis of the primary stability in uncemented hip prostheses. Artificial Organs 23 (1999) 851-859
On the secondary stability of coated cementless hip replacement: parameters that affected interface strength
Orlik J., Zhurov A., and Middleton J. On the secondary stability of coated cementless hip replacement: parameters that affected interface strength. Medical Engineering & Physics 25 (2003) 825-831
Effects of femoral component material properties on cementless fixation in total hip arthroplasty. A comparison study between carbon composite, titanium alloy, and stainless steel
Otani T., Whiteside L.A., White S.E., and McCarthy D.S. Effects of femoral component material properties on cementless fixation in total hip arthroplasty. A comparison study between carbon composite, titanium alloy, and stainless steel. Journal of Arthroplasty 8 (1993) 67-74
Frictional interface micromotions and anisotropic stress distribution in a femoral total hip component
Rubin P.J., Rakotomanana R.L., Leyvraz P.F., Zysset P.K., Curnier A., and Heegaard J.H. Frictional interface micromotions and anisotropic stress distribution in a femoral total hip component. Journal of Biomechanics 26 (1993) 725-739
Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants
Shirazi-Adl A., Dammak M., and Paiement G. Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants. Journal of Biomedical Materials Research 27 (1993) 167-175
Pre-clinical validation of a new partially cemented femoral prosthesis by synergetic use of numerical and experimental methods
Viceconti M., Cristofolini L., Baleani M., and Toni A. Pre-clinical validation of a new partially cemented femoral prosthesis by synergetic use of numerical and experimental methods. Journal of Biomechanics 34 (2001) 723-731