메뉴 건너뛰기




Volumn 27, Issue 3, 2011, Pages 875-884

Passive multivariable temperature and conductivity RFID sensors for single-use biopharmaceutical manufacturing components

Author keywords

Component integration; Multivariable sensing; Multivariate data analysis; Passive RFID sensors; Single use biopharmaceutical components

Indexed keywords

COMPONENT INTEGRATION; MULTIVARIABLE SENSING; MULTIVARIATE DATA ANALYSIS; PASSIVE RFID; SINGLE-USE BIOPHARMACEUTICAL COMPONENTS;

EID: 79958259720     PISSN: 87567938     EISSN: 15206033     Source Type: Journal    
DOI: 10.1002/btpr.586     Document Type: Article
Times cited : (22)

References (45)
  • 1
    • 58249091622 scopus 로고    scopus 로고
    • Disposable bioprocessing: the future has arrived
    • Rao G, Moreira A, Brorson K. Disposable bioprocessing: the future has arrived. Biotechnol Bioeng. 2009; 102: 348-356.
    • (2009) Biotechnol Bioeng. , vol.102 , pp. 348-356
    • Rao, G.1    Moreira, A.2    Brorson, K.3
  • 2
    • 77953910060 scopus 로고    scopus 로고
    • Operations and quality systems building in success
    • Montgomery SA. Operations and quality systems building in success. BioProcess Int Suppl. 2006; 58-71.
    • (2006) BioProcess Int Suppl. , pp. 58-71
    • Montgomery, S.A.1
  • 3
    • 77953908759 scopus 로고    scopus 로고
    • Single-use process systems
    • Available at.
    • Sellick I, Pora H. Single-use process systems. Next Gen Pharm. 2008; Available at.
    • (2008) Next Gen Pharm.
    • Sellick, I.1    Pora, H.2
  • 4
    • 77951643016 scopus 로고    scopus 로고
    • The role of disposables in rapid response manufacturing
    • Sinclair A, Monge M. The role of disposables in rapid response manufacturing. Biopharm Int. 2009; 28-31.
    • (2009) Biopharm Int. , pp. 28-31
    • Sinclair, A.1    Monge, M.2
  • 5
    • 33751307949 scopus 로고    scopus 로고
    • The ROI case: economic justification for disposables in biopharmaceutical manufacturing
    • Langer ES, Ranck J. The ROI case: economic justification for disposables in biopharmaceutical manufacturing. BioProcess Int. 2005; 10: S46-S50.
    • (2005) BioProcess Int. , vol.10
    • Langer, E.S.1    Ranck, J.2
  • 6
    • 77952083134 scopus 로고    scopus 로고
    • Environmental impact of single-use and reusable bioprocess systems
    • Rawlings B, Pora H. Environmental impact of single-use and reusable bioprocess systems. BioProcess Int. 2009; 7: 18-25.
    • (2009) BioProcess Int. , vol.7 , pp. 18-25
    • Rawlings, B.1    Pora, H.2
  • 7
    • 77957028965 scopus 로고    scopus 로고
    • Minimizing the environmental footprint of bioprocesses. Part 1: Introduction and evaluation of solid-waste disposal
    • Junker B. Minimizing the environmental footprint of bioprocesses. Part 1: Introduction and evaluation of solid-waste disposal. BioProcess Int. 2010; 8: 62-71.
    • (2010) BioProcess Int. , vol.8 , pp. 62-71
    • Junker, B.1
  • 8
    • 78649649955 scopus 로고    scopus 로고
    • Minimizing the environmental footprint of bioprocesses. Part 2: Evaluation of wastewater, electricity, and air emissions
    • Junker B. Minimizing the environmental footprint of bioprocesses. Part 2: Evaluation of wastewater, electricity, and air emissions. BioProcess Int. 2010; 8: 36-46.
    • (2010) BioProcess Int. , vol.8 , pp. 36-46
    • Junker, B.1
  • 9
    • 79958273328 scopus 로고    scopus 로고
    • Radiofrequency identification feasibility studies and pilot programs for drugs. Guidance for FDA Staff and Industry Compliance Policy Guides Sec 400210. Available at.
    • Radiofrequency identification feasibility studies and pilot programs for drugs. Guidance for FDA Staff and Industry Compliance Policy Guides Sec 400210. 2004. Available at.
    • (2004)
  • 13
    • 33748938728 scopus 로고    scopus 로고
    • Bioprocess monitoring and computer control: key roots of the current PAT initiative
    • Junker B, Wang HY. Bioprocess monitoring and computer control: key roots of the current PAT initiative. Biotechnol Bioeng. 2006; 95: 226-261.
    • (2006) Biotechnol Bioeng. , vol.95 , pp. 226-261
    • Junker, B.1    Wang, H.Y.2
  • 14
    • 33846206935 scopus 로고    scopus 로고
    • Multianalyte chemical identification and quantitation using a single radio frequency identification sensor
    • Potyrailo RA, Morris WG. Multianalyte chemical identification and quantitation using a single radio frequency identification sensor. Anal Chem. 2007; 79: 45-51.
    • (2007) Anal Chem. , vol.79 , pp. 45-51
    • Potyrailo, R.A.1    Morris, W.G.2
  • 15
    • 41649095685 scopus 로고    scopus 로고
    • Position-independent chemical quantitation with passive 13.56-MHz radio frequency identification (RFID) sensors
    • Potyrailo RA, Mouquin H, Morris WG. Position-independent chemical quantitation with passive 13.56-MHz radio frequency identification (RFID) sensors. Talanta. 2008; 75: 624-628.
    • (2008) Talanta. , vol.75 , pp. 624-628
    • Potyrailo, R.A.1    Mouquin, H.2    Morris, W.G.3
  • 17
    • 73849138121 scopus 로고    scopus 로고
    • Development of radio-frequency identification sensors based on organic electronic sensing materials for selective detection of toxic vapors
    • Potyrailo RA, Surman C, Go S, Lee Y, Sivavec T, Morris WG. Development of radio-frequency identification sensors based on organic electronic sensing materials for selective detection of toxic vapors. J Appl Phys. 2009; 106: 124902.
    • (2009) J Appl Phys. , vol.106 , pp. 124902
    • Potyrailo, R.A.1    Surman, C.2    Go, S.3    Lee, Y.4    Sivavec, T.5    Morris, W.G.6
  • 19
    • 77953904322 scopus 로고    scopus 로고
    • Suitability of selected single-use process monitoring and control technology
    • Clark KJR, Furey J. Suitability of selected single-use process monitoring and control technology. BioProcess Int. 2006; 4: S16-S20.
    • (2006) BioProcess Int. , vol.4
    • Clark, K.J.R.1    Furey, J.2
  • 20
    • 33645217831 scopus 로고    scopus 로고
    • Real-time bioprocess monitoring: Part I: In situ sensors
    • Vojinovic V, Cabral JMS, Fonseca LP. Real-time bioprocess monitoring: Part I: In situ sensors. Sens Actuators B. 2006; 114: 1083-1091.
    • (2006) Sens Actuators B. , vol.114 , pp. 1083-1091
    • Vojinovic, V.1    Cabral, J.M.S.2    Fonseca, L.P.3
  • 21
    • 33745482610 scopus 로고    scopus 로고
    • Improvement of bioprocess monitoring: development of novel concepts
    • Clementschitsch F, Bayer K. Improvement of bioprocess monitoring: development of novel concepts. Microbiol Cell Fact. 2006; 19.
    • (2006) Microbiol Cell Fact. , pp. 19
    • Clementschitsch, F.1    Bayer, K.2
  • 22
    • 62249114097 scopus 로고    scopus 로고
    • Development and application of an excitation ratiometric optical pH sensor for bioprocess monitoring
    • Badugu R, Kostov Y, Rao G, Tolosa L. Development and application of an excitation ratiometric optical pH sensor for bioprocess monitoring. Biotechnol Prog. 2008; 24: 1393-1401.
    • (2008) Biotechnol Prog. , vol.24 , pp. 1393-1401
    • Badugu, R.1    Kostov, Y.2    Rao, G.3    Tolosa, L.4
  • 23
    • 62249151016 scopus 로고    scopus 로고
    • Development of a system for the on-line measurement of carbon dioxide production in microbioreactors: application to aerobic batch cultivations of candida utilis
    • Van Leeuwen M, Heijnen JJ, Gardeniers H, Van Der Wielen LAM, Van Gulik WM. Development of a system for the on-line measurement of carbon dioxide production in microbioreactors: application to aerobic batch cultivations of candida utilis. Biotechnol Prog. 2009; 25: 892-897.
    • (2009) Biotechnol Prog. , vol.25 , pp. 892-897
    • Van Leeuwen, M.1    Heijnen, J.J.2    Gardeniers, H.3    Van Der Wielen, L.A.M.4    Van Gulik, W.M.5
  • 27
    • 33645572989 scopus 로고    scopus 로고
    • A 13.56 MHz CMOS RF identification passive tag LSI with ferroelectric random access memory
    • E88-C
    • Masui S, Teramoto T. A 13.56 MHz CMOS RF identification passive tag LSI with ferroelectric random access memory. IEICE Trans Electron. 2005; E88-C: 601-607.
    • (2005) IEICE Trans Electron. , pp. 601-607
    • Masui, S.1    Teramoto, T.2
  • 30
    • 79958258548 scopus 로고    scopus 로고
    • Production and process controls. Available at.
    • Production and process controls. Available at: 2010.
    • (2010)
  • 32
    • 0014762054 scopus 로고
    • Inductive conductivity meter for monitoring the salinity of dialysis water
    • BME-17
    • Diamond JM. Inductive conductivity meter for monitoring the salinity of dialysis water. IEEE Trans Bio-Med Eng. 1970; BME-17: 109-117.
    • (1970) IEEE Trans Bio-Med Eng. , pp. 109-117
    • Diamond, J.M.1
  • 33
    • 0022046247 scopus 로고
    • The exact theory of inductive conductivity sensors for oceanographic application
    • Striggow K, Dankert R. The exact theory of inductive conductivity sensors for oceanographic application. IEEE J Oceanic Eng. 1985; 10: 175-179.
    • (1985) IEEE J Oceanic Eng. , vol.10 , pp. 175-179
    • Striggow, K.1    Dankert, R.2
  • 34
    • 34547488882 scopus 로고    scopus 로고
    • Sensitivity tunable inductive fluid conductivity sensor based on RF phase detection
    • Natarajan SP, Weller TM, Fries DP. Sensitivity tunable inductive fluid conductivity sensor based on RF phase detection. IEEE Sensors J. 2007; 7: 1300-1301.
    • (2007) IEEE Sensors J. , vol.7 , pp. 1300-1301
    • Natarajan, S.P.1    Weller, T.M.2    Fries, D.P.3
  • 35
    • 54949123405 scopus 로고    scopus 로고
    • Simultaneous noncontact measurement of water level and conductivity
    • Yin W, Peyton AJ, Zysko G, Denno R. Simultaneous noncontact measurement of water level and conductivity. IEEE Trans Instrum Meas. 2008; 57: 2665-2669.
    • (2008) IEEE Trans Instrum Meas. , vol.57 , pp. 2665-2669
    • Yin, W.1    Peyton, A.J.2    Zysko, G.3    Denno, R.4
  • 37
    • 0034247081 scopus 로고    scopus 로고
    • A resonant printed-circuit sensor for remote query monitoring of environmental parameters
    • Ong KG, Grimes CA. A resonant printed-circuit sensor for remote query monitoring of environmental parameters. Smart Mater Struct. 2000; 9: 421-428.
    • (2000) Smart Mater Struct. , vol.9 , pp. 421-428
    • Ong, K.G.1    Grimes, C.A.2
  • 38
    • 27644575993 scopus 로고    scopus 로고
    • Transponder-based sensor for monitoring electrical properties of biological cell solutions
    • Hofmann MC, Kensy F, Buechs J, Mokwa W, Schnakenberg U. Transponder-based sensor for monitoring electrical properties of biological cell solutions. J Biosci Bioeng. 2005; 100: 172-177.
    • (2005) J Biosci Bioeng. , vol.100 , pp. 172-177
    • Hofmann, M.C.1    Kensy, F.2    Buechs, J.3    Mokwa, W.4    Schnakenberg, U.5
  • 40
    • 79958293410 scopus 로고    scopus 로고
    • Methods and Systems for Calibration of RFID Sensors. 2011 US Patent 7,911,345. Available at.
    • Potyrailo RA, Morris WG. Methods and Systems for Calibration of RFID Sensors. 2011 US Patent 7, 911, 345. 2009. Available at.
    • (2009)
    • Potyrailo, R.A.1    Morris, W.G.2
  • 42
    • 0343442411 scopus 로고    scopus 로고
    • Non-contact passive electromagnetic transmitter to any capacitive sensor-design, theory, and model tests
    • Jachowicz RS, Wojtowicz G, Weremczuk J. Non-contact passive electromagnetic transmitter to any capacitive sensor-design, theory, and model tests. Sens Actuators A. 2000; 85: 402-408.
    • (2000) Sens Actuators A. , vol.85 , pp. 402-408
    • Jachowicz, R.S.1    Wojtowicz, G.2    Weremczuk, J.3
  • 43
    • 77953887966 scopus 로고    scopus 로고
    • Modeling of selectivity of multi-analyte response of passive radio frequency identification (RFID) sensors
    • In: Columbus, OH: Elsevier Science; Talk MMAS11.
    • Potyrailo RA, Go S, Morris WG. Modeling of selectivity of multi-analyte response of passive radio frequency identification (RFID) sensors. In: 12th International Meeting on Chemical Sensors. Columbus, OH: Elsevier Science; 2008. Talk MMAS11.
    • (2008) 12th International Meeting on Chemical Sensors
    • Potyrailo, R.A.1    Go, S.2    Morris, W.G.3
  • 44
    • 0034228462 scopus 로고    scopus 로고
    • Computational methods for the analysis of chemical sensor array data from volatile analytes
    • Jurs PC, Bakken GA, McClelland HE. Computational methods for the analysis of chemical sensor array data from volatile analytes. Chem Rev. 2000; 100: 2649-2678.
    • (2000) Chem Rev. , vol.100 , pp. 2649-2678
    • Jurs, P.C.1    Bakken, G.A.2    McClelland, H.E.3
  • 45
    • 79958282770 scopus 로고    scopus 로고
    • System and Method for Monitoring Parameters in Containers. US Patent 7,775,083.
    • Potyrailo RA, Pizzi VF, Wang H. System and Method for Monitoring Parameters in Containers. 2010. US Patent 7, 775, 083.
    • (2010)
    • Potyrailo, R.A.1    Pizzi, V.F.2    Wang, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.