메뉴 건너뛰기




Volumn 99, Issue 2, 2011, Pages 155-160

Use of megavoltage cine-images for studying intra-thoracic motion during radiotherapy for locally advanced lung cancer

Author keywords

4 Dimensional CT scan; Intra fraction tumor motion; Megavolt imaging; Respiratory management; Treatment verification

Indexed keywords

ARTICLE; CANCER LOCALIZATION; CANCER SIZE; CANCER STAGING; CLINICAL ARTICLE; FOUR DIMENSIONAL COMPUTED TOMOGRAPHY; HUMAN; IMAGE QUALITY; LUNG HILUS; LUNG NON SMALL CELL CANCER; MEGAVOLTAGE RADIOTHERAPY; MOTION ANALYSIS SYSTEM; PRIORITY JOURNAL; THERAPY EFFECT; TREATMENT OUTCOME;

EID: 79958083290     PISSN: 01678140     EISSN: 18790887     Source Type: Journal    
DOI: 10.1016/j.radonc.2011.05.037     Document Type: Article
Times cited : (8)

References (26)
  • 1
    • 61449238276 scopus 로고    scopus 로고
    • Radiotherapy for lung cancer: Clinical impact of recent technical advances
    • C.J.A. Haasbeek, B.J. Slotman, and S. Senan Radiotherapy for lung cancer: clinical impact of recent technical advances Lung Cancer 64 2008 1 8
    • (2008) Lung Cancer , vol.64 , pp. 1-8
    • Haasbeek, C.J.A.1    Slotman, B.J.2    Senan, S.3
  • 4
    • 38349073468 scopus 로고    scopus 로고
    • A study of tumor motion management in the conformal radiotherapy of lung cancer
    • S.S.C. Burnett, K.E. Sixel, P.C.F. Cheung, and J.D.P. Hoisak A study of tumor motion management in the conformal radiotherapy of lung cancer Radiother Oncol 86 2008 77 85
    • (2008) Radiother Oncol , vol.86 , pp. 77-85
    • Burnett, S.S.C.1    Sixel, K.E.2    Cheung, P.C.F.3    Hoisak, J.D.P.4
  • 8
    • 77249170180 scopus 로고    scopus 로고
    • Vorsprung durch Technik: Evolution, implementation, QA and safety of new technology in radiotherapy
    • D.I. Thwaites, and D. Verellen Vorsprung durch Technik: evolution, implementation, QA and safety of new technology in radiotherapy Radiother Oncol 94 2010 125 128
    • (2010) Radiother Oncol , vol.94 , pp. 125-128
    • Thwaites, D.I.1    Verellen, D.2
  • 10
    • 79958130610 scopus 로고    scopus 로고
    • Automated localization method for a lung tumor on EPID images without implanted markers in stereotactic body radiotherapy
    • H. Arimura, Y. Shioyama, and K. Nakamura Automated localization method for a lung tumor on EPID images without implanted markers in stereotactic body radiotherapy Int J Radiat Oncol Biol Phys 75 2009 S97
    • (2009) Int J Radiat Oncol Biol Phys , vol.75 , pp. 97
    • Arimura, H.1    Shioyama, Y.2    Nakamura, K.3
  • 14
    • 49549102888 scopus 로고    scopus 로고
    • Utility of four dimensional computed tomography for analysis of intrafractional and interfractional variation in lung volumes
    • B. Rosen, G. Starkschall, and K. Britton Utility of four dimensional computed tomography for analysis of intrafractional and interfractional variation in lung volumes Int J Radiat Oncol Biol Phys 72 2008 288 294
    • (2008) Int J Radiat Oncol Biol Phys , vol.72 , pp. 288-294
    • Rosen, B.1    Starkschall, G.2    Britton, K.3
  • 15
    • 79957550479 scopus 로고    scopus 로고
    • Quality assurance of 4D-CT scan techniques in multicenter phase III trial of surgery versus stereotactic radiotherapy (radiosurgery or surgery for operable early stage (stage 1A) non-small-cell lung cancer [ROSEL] study)
    • C.W. Hurkmans, M. van Lieshout, and D. Schuring Quality assurance of 4D-CT scan techniques in multicenter phase III trial of surgery versus stereotactic radiotherapy (radiosurgery or surgery for operable early stage (stage 1A) non-small-cell lung cancer [ROSEL] study) Int J Radiat Oncol Biol Phys 80 2011 918 927
    • (2011) Int J Radiat Oncol Biol Phys , vol.80 , pp. 918-927
    • Hurkmans, C.W.1    Van Lieshout, M.2    Schuring, D.3
  • 19
    • 77249134524 scopus 로고    scopus 로고
    • The European Society of Therapeutic Radiology and Oncology-European Institute of Radiothearpy (ESTRO-EIR) report on 3D CT-based in-room image guidance systems: A practical and technical review and guide
    • S. Korreman, C. Rasch, and H. McNair The European Society of Therapeutic Radiology and Oncology-European Institute of Radiothearpy (ESTRO-EIR) report on 3D CT-based in-room image guidance systems: a practical and technical review and guide Radiother Oncol 94 2010 129 144
    • (2010) Radiother Oncol , vol.94 , pp. 129-144
    • Korreman, S.1    Rasch, C.2    McNair, H.3
  • 24
    • 33646483975 scopus 로고    scopus 로고
    • Prediction of lung tumour position based on spirometry and on abdominal displacement: Accuracy and reproducibility
    • J.D.P. Hoisak, K.E. Sixel, R. Tirona, P.C.F. Cheung, and J.-P. Pignol Prediction of lung tumour position based on spirometry and on abdominal displacement: accuracy and reproducibility Radiother Oncol 78 2006 339 346
    • (2006) Radiother Oncol , vol.78 , pp. 339-346
    • Hoisak, J.D.P.1    Sixel, K.E.2    Tirona, R.3    Cheung, P.C.F.4    Pignol, J.-P.5
  • 25
    • 34447104341 scopus 로고    scopus 로고
    • Predictability of lung tumor motion during normal breathing based on external marker monitoring
    • S. Korreman, H. Mostafavi, A. Grow, A. Boyer, and Q. Le Predictability of lung tumor motion during normal breathing based on external marker monitoring Med Phys 31 2004 1759 1760
    • (2004) Med Phys , vol.31 , pp. 1759-1760
    • Korreman, S.1    Mostafavi, H.2    Grow, A.3    Boyer, A.4    Le, Q.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.