-
2
-
-
2542497090
-
American Society of Nuclear Cardiology and Society of Nuclear Medicine joint position statement: Attenuation correction of myocardial perfusion SPECT scintigraphy
-
DOI 10.1016/j.nuclcard.2003.12.001, PII S1071358103008110
-
Heller GV, Links J, Bateman TM, Ziffer JA, Ficaro E, Cohen MC, et al. American Society of Nuclear Cardiology and Society of Nuclear Medicine joint position statement: Attenuation correction of myocardial perfusion SPECT scintigraphy. J Nucl Cardiol 2004;11:229-30. (Pubitemid 38949918)
-
(2004)
Journal of Nuclear Cardiology
, vol.11
, Issue.2
, pp. 229-230
-
-
Heller, G.V.1
Links, J.2
Bateman, T.M.3
Ziffer, J.A.4
Ficaro, E.5
Cohen, M.C.6
Hendel, R.C.7
-
3
-
-
53149085937
-
SPECT/CT imaging: Clinical utility of an emerging technology
-
Bybel B, Brunken RC, DiFilippo FP, Neumann DR, Wu G, Cerqueira MD. SPECT/CT imaging: Clinical utility of an emerging technology. Radiographics 2008;28:1097-113.
-
(2008)
Radiographics
, vol.28
, pp. 1097-1113
-
-
Bybel, B.1
Brunken, R.C.2
DiFilippo, F.P.3
Neumann, D.R.4
Wu, G.5
Cerqueira, M.D.6
-
4
-
-
33846598849
-
SPECT attenuation correction: An essential tool to realize nuclear cardiology's manifest destiny
-
DOI 10.1016/j.nuclcard.2006.12.144, PII S1071358106008324
-
Garcia EV. SPECT attenuation correction: An essential tool to realize nuclear cardiology's manifest destiny. J Nucl Cardiol 2007;14:16-24. (Pubitemid 46172886)
-
(2007)
Journal of Nuclear Cardiology
, vol.14
, Issue.1
, pp. 16-24
-
-
Garcia, E.V.1
-
5
-
-
33947359091
-
Attenuation artifact, attenuation correction, and the future of myocardial perfusion SPECT
-
DOI 10.1016/j.nuclcard.2007.01.037, PII S1071358107001092
-
Singh B, Bateman TM, Case JA, Heller G. Attenuation artifact, attenuation correction, and the future of myocardial perfusion SPECT. J Nucl Cardiol 2007;14:153-64. (Pubitemid 46444685)
-
(2007)
Journal of Nuclear Cardiology
, vol.14
, Issue.2
, pp. 153-164
-
-
Singh, B.1
Bateman, T.M.2
Case, J.A.3
Heller, G.4
-
6
-
-
79958092789
-
-
Des Plaines IL: IMV Medical Information Division
-
IMV Medicine Market Summary Report, Des Plaines IL: IMV Medical Information Division. 2008.
-
(2008)
IMV Medicine Market Summary Report
-
-
-
7
-
-
33846861435
-
Interpretation of myocardial perfusion imaging
-
Heller GV, Hendel RC, editors. New York: McGraw-Hill
-
Hendel RC. Interpretation of myocardial perfusion imaging. In: Heller GV, Hendel RC, editors. Nuclear cardiology: Practical applications. New York: McGraw-Hill; 2004. p. 157-74.
-
(2004)
Nuclear Cardiology: Practical Applications
, pp. 157-174
-
-
Hendel, R.C.1
-
8
-
-
77957366638
-
Ambulatory cardiac single-photon emission computed tomography at the primary care physician's office: A descriptive study
-
Chaptini N, Dontaraju VS, Concepcion F, Muradi HA, Alyousef T, Del Pilar Aristizabal Canaval M, et al. Ambulatory cardiac single-photon emission computed tomography at the primary care physician's office: A descriptive study. J Ambul Care Manage 2010;33:328-35.
-
(2010)
J Ambul Care Manage
, vol.33
, pp. 328-335
-
-
Chaptini, N.1
Dontaraju, V.S.2
Concepcion, F.3
Muradi, H.A.4
Alyousef, T.5
Del Pilar Aristizabal Canaval, M.6
-
9
-
-
41949100418
-
Changes in the appearance of attenuation artefacts due to change in posture in myocardial perfusion imaging
-
DOI 10.1097/MNM.0b013e3282f5d2ab, PII 0000623120080500000006
-
Tonge CM, Armstrong IS, Arumugam P, James JM, Al-Bahrani GI, Lawson RS, et al. Changes in the appearance of attenuation artefacts due to change in posture in myocardial perfusion imaging. Nucl Med Commun 2008;29:441-7. (Pubitemid 351507538)
-
(2008)
Nuclear Medicine Communications
, vol.29
, Issue.5
, pp. 441-447
-
-
Tonge, C.M.1
Armstrong, I.S.2
Arumugam, P.3
James, J.M.4
Al-Bahrani, G.I.5
Lawson, R.S.6
Shields, R.A.7
Prescott, M.C.8
-
10
-
-
66049116876
-
A novel cardiac SPECT system with X-ray-based attenuation correction using the same solid state detectors for both emission and transmission scans
-
Conwell R, Kindem J, Bai C, Maddahi J. A novel cardiac SPECT system with X-ray-based attenuation correction using the same solid state detectors for both emission and transmission scans. J Nucl Med 2008;49:64.
-
(2008)
J Nucl Med
, vol.49
, pp. 64
-
-
Conwell, R.1
Kindem, J.2
Bai, C.3
Maddahi, J.4
-
11
-
-
79958131737
-
Clinical evaluation of a low-dose, X-ray-based transmission imaging technique for attenuation correction of SPECT myocardial perfusion images
-
Maddahi J, Conwell R, Mendez R, Babla H, Bai C, Kindem J, et al. Clinical evaluation of a low-dose, X-ray-based transmission imaging technique for attenuation correction of SPECT myocardial perfusion images. Eur Heart J 2009;11:S46-8.
-
(2009)
Eur Heart J
, vol.11
-
-
Maddahi, J.1
Conwell, R.2
Mendez, R.3
Babla, H.4
Bai, C.5
Kindem, J.6
-
12
-
-
77957366440
-
Stress testing
-
Mann A, Heller GV, Hendel RC, editors. New York: McGraw-Hill
-
Abbott BG. Stress testing. In: Mann A, Heller GV, Hendel RC, editors. Nuclear cardiology: Technical applications. New York: McGraw-Hill; 2007. p. 97-106.
-
(2007)
Nuclear Cardiology: Technical Applications
, pp. 97-106
-
-
Abbott, B.G.1
-
13
-
-
79958180833
-
Pharmacologic Stress testing in myocardial perfusion imaging: Technical applications
-
Mann A, Heller GV, Hendel RC, editors. New York: McGraw-Hill
-
Doukky R. Pharmacologic Stress testing in myocardial perfusion imaging: Technical applications. In: Mann A, Heller GV, Hendel RC, editors. Nuclear Cardiology: Technical Applications. New York: McGraw-Hill; 2007. p. 107-24.
-
(2007)
Nuclear Cardiology: Technical Applications
, pp. 107-124
-
-
Doukky, R.1
-
14
-
-
33845496791
-
Stress protocols and tracers
-
DOI 10.1016/j.nuclcard.2006.08.011, PII S1071358106005678
-
Henzlova MJ, Cerqueira MD, Mahmarian JJ, Yao SS. Stress protocols and tracers. J Nucl Cardiol 2006;13:e80-90. (Pubitemid 44913649)
-
(2006)
Journal of Nuclear Cardiology
, vol.13
, Issue.6
-
-
Henzlova, M.J.1
Cerqueira, M.D.2
Mahmarian, J.J.3
Yao, S.-S.4
-
15
-
-
33845494101
-
Myocardial perfusion and function single photon emission computed tomography
-
Hansen CL, Goldstein RA, Berman DS, Churchwell KB, Cooke CD, Corbett JR, et al. Myocardial perfusion and function single photon emission computed tomography. J Nucl Cardiol 2006;13:e97-120.
-
(2006)
J Nucl Cardiol
, vol.13
-
-
Hansen, C.L.1
Goldstein, R.A.2
Berman, D.S.3
Churchwell, K.B.4
Cooke, C.D.5
Corbett, J.R.6
-
17
-
-
0018750969
-
Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease
-
Diamond GA, Forrester JS. Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease. N Engl J Med 1979;300:1350-8. (Pubitemid 9198112)
-
(1979)
New England Journal of Medicine
, vol.300
, Issue.24
, pp. 1350-1358
-
-
Diamond, G.A.1
Forrester, J.S.2
-
18
-
-
0032510639
-
Prediction of coronary heart disease using risk factor categories
-
Wilson PW, D'Agostino RB, Levy D, Belanger AM, Silbershatz H, Kannel WB. Prediction of coronary heart disease using risk factor categories. Circulation 1998;97:1837-47. (Pubitemid 28213628)
-
(1998)
Circulation
, vol.97
, Issue.18
, pp. 1837-1847
-
-
Wilson, P.W.F.1
D'Agostino, R.B.2
Levy, D.3
Belanger, A.M.4
Silbershatz, H.5
Kannel, W.B.6
-
19
-
-
40849096343
-
Application of Appropriateness Criteria to Stress Single-Photon Emission Computed Tomography Sestamibi Studies and Stress Echocardiograms in an Academic Medical Center
-
DOI 10.1016/j.jacc.2007.10.064, PII S0735109708002568
-
Gibbons RJ, Miller TD, Hodge D, Urban L, Araoz PA, Pellikka P, et al. Application of appropriateness criteria to stress single-photon emission computed tomography sestamibi studies and stress echocardiograms in an academic medical center. J Am Coll Cardiol 2008;51:1283-9. (Pubitemid 351400897)
-
(2008)
Journal of the American College of Cardiology
, vol.51
, Issue.13
, pp. 1283-1289
-
-
Gibbons, R.J.1
Miller, T.D.2
Hodge, D.3
Urban, L.4
Araoz, P.A.5
Pellikka, P.6
McCully, R.B.7
-
20
-
-
73049086777
-
A multicenter assessment of the use ofsingle-photon emission computed tomography myocardial perfusion imaging with appropriateness criteria
-
Hendel RC, Cerqueira M, Douglas PS, Caruth KC, Allen JM, Jensen NC, et al. A multicenter assessment of the use ofsingle-photon emission computed tomography myocardial perfusion imaging with appropriateness criteria. J Am Coll Cardiol 2010;55:156-62.
-
(2010)
J Am Coll Cardiol
, vol.55
, pp. 156-162
-
-
Hendel, R.C.1
Cerqueira, M.2
Douglas, P.S.3
Caruth, K.C.4
Allen, J.M.5
Jensen, N.C.6
-
21
-
-
44949233677
-
Diagnostic accuracy of supine and prone thallium-201 stress myocardial perfusion single-photon emission computed tomography to detect coronary artery disease in inferior wall of left ventricle
-
DOI 10.1007/s12149-008-0118-3
-
Katayama T, Ogata N, Tsuruya Y. Diagnostic accuracy of supine and prone thallium-201 stress myocardial perfusion single-photon emission computed tomography to detect coronary artery disease in inferior wall of left ventricle. Ann Nucl Med 2008;22:317-21. (Pubitemid 351809799)
-
(2008)
Annals of Nuclear Medicine
, vol.22
, Issue.4
, pp. 317-321
-
-
Katayama, T.1
Ogata, N.2
Tsuruya, Y.3
-
22
-
-
33645542751
-
Combined supine and prone quantitative myocardial perfusion SPECT: Method development and clinical validation in patients with no known coronary artery disease
-
Nishina H, Slomka PJ, Abidov A, Yoda S, Akincioglu C, Kang X, et al. Combined supine and prone quantitative myocardial perfusion SPECT: Method development and clinical validation in patients with no known coronary artery disease. J Nucl Med 2006;47:51-8. (Pubitemid 46768512)
-
(2006)
Journal of Nuclear Medicine
, vol.47
, Issue.1
, pp. 51-58
-
-
Nishina, H.1
Slomka, P.J.2
Abidov, A.3
Yoda, S.4
Akincioglu, C.5
Kang, X.6
Cohen, I.7
Hayes, S.W.8
Friedman, J.D.9
Germano, G.10
Berman, D.S.11
|