메뉴 건너뛰기




Volumn 5, Issue 1, 2011, Pages 166-172

Noninvasive diagnostic devices for diabetes through measuring tear glucose

Author keywords

Biosensor; Nanomaterials; Noninvasive diagnostic device; Tear glucose

Indexed keywords

GLUCOSE; NANOPARTICLE;

EID: 79957987989     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229681100500123     Document Type: Review
Times cited : (136)

References (51)
  • 1
    • 65449117604 scopus 로고    scopus 로고
    • Geneva (Switzerland): WHO; Available from: Accessed on December 23,2010
    • World Health Organization. Diabetes: Fact sheet N° 312. Geneva (Switzerland): WHO; 2009. Available from: http://www.who.int/mediacentre/ factsheets/fs312/en/. Accessed on December 23,2010.
    • (2009) Diabetes: Fact Sheet N° 312
  • 2
    • 84887465771 scopus 로고    scopus 로고
    • Toronto (Ontario): Canadian Diabetes Association; Available from
    • Canadian Diabetes Association. Diabetes Progress Report 2005. Toronto (Ontario): Canadian Diabetes Association; 2005. Available from: http://www.diabetes.ca/files/diabetesreport2005/CDA-diabetesreport-2005-en.pdf.
    • (2005) Diabetes Progress Report 2005
  • 3
    • 0038445922 scopus 로고    scopus 로고
    • The use of Fourier-transform infrared spectroscopy for the quantitative determination of glucose concentration in whole blood
    • Shen YC, Davies AG, Linfield EH, Elsey TS, Taday PF, Arnone DD. The use of Fourier-transform infrared spectroscopy for the quantitative determination of glucose concentration in whole blood. Phys Med Biol. 2003;48(13):2023-32.
    • (2003) Phys Med Biol , vol.48 , Issue.13 , pp. 2023-2032
    • Shen, Y.C.1    Davies, A.G.2    Linfield, E.H.3    Elsey, T.S.4    Taday, P.F.5    Arnone, D.D.6
  • 4
    • 0034064170 scopus 로고    scopus 로고
    • Noninvasive blood glucose measurements by near-infrared transmission spectroscopy across human tongues
    • Burmeister JJ, Arnold MA, Small GW. Noninvasive blood glucose measurements by near-infrared transmission spectroscopy across human tongues. Diabetes Technol Ther. 2000;2(1):5-16.
    • (2000) Diabetes Technol Ther , vol.2 , Issue.1 , pp. 5-16
    • Burmeister, J.J.1    Arnold, M.A.2    Small, G.W.3
  • 5
    • 33847271586 scopus 로고    scopus 로고
    • Development and validation of a multiwavelength spatial domain near-infrared oximeter to detect cerebral hypoxia-ischemia
    • Nelson LA, McCann JC, Loepke AW, Wu J, Ben Dor B, Kurth CD. Development and validation of a multiwavelength spatial domain near-infrared oximeter to detect cerebral hypoxia-ischemia. J Biomed Opt. 2006;11(6):064022.
    • (2006) J Biomed Opt , vol.11 , Issue.6 , pp. 064022
    • Nelson, L.A.1    McCann, J.C.2    Loepke, A.W.3    Wu, J.4    Ben Dor, B.5    Kurth, C.D.6
  • 6
    • 0242300683 scopus 로고    scopus 로고
    • Non-invasive glucose monitoring by NAD(P)H autofluorescence spectroscopy in fibroblasts and adipocytes: A model for skin glucose sensing
    • Evans ND, Gnudi L, Rolinski OJ, Birch DJ, Pickup JC. Non-invasive glucose monitoring by NAD(P)H autofluorescence spectroscopy in fibroblasts and adipocytes: a model for skin glucose sensing. Diabetes Technol Ther. 2003;5(5):807-16.
    • (2003) Diabetes Technol Ther , vol.5 , Issue.5 , pp. 807-816
    • Evans, N.D.1    Gnudi, L.2    Rolinski, O.J.3    Birch, D.J.4    Pickup, J.C.5
  • 7
    • 34547311895 scopus 로고    scopus 로고
    • Feasibility analysis of an epidermal glucose sensor based on time-resolved fluorescence
    • Katika KM, Pilon L. Feasibility analysis of an epidermal glucose sensor based on time-resolved fluorescence. Appl Opt. 2007;46(16):3359-68.
    • (2007) Appl Opt , vol.46 , Issue.16 , pp. 3359-3368
    • Katika, K.M.1    Pilon, L.2
  • 8
    • 0036324351 scopus 로고    scopus 로고
    • Measurement of aqueous glucose in a model anterior chamber using Raman spectroscopy
    • Lambert JL, Morookian JM, Sirk SJ, Borchert MS. Measurement of aqueous glucose in a model anterior chamber using Raman spectroscopy. J Raman Spectrosc. 2002;33(7):524-9.
    • (2002) J Raman Spectrosc , vol.33 , Issue.7 , pp. 524-529
    • Lambert, J.L.1    Morookian, J.M.2    Sirk, S.J.3    Borchert, M.S.4
  • 10
    • 0020077396 scopus 로고
    • Noninvasive glucose monitoring of the aqueous humor of the eye: Part I. Measurement of very small optical rotations
    • Rabinovitch B, March WF, Adams RL. Noninvasive glucose monitoring of the aqueous humor of the eye: Part I. Measurement of very small optical rotations. Diabetes Care. 1982;5(3):254-8.
    • (1982) Diabetes Care , vol.5 , Issue.3 , pp. 254-258
    • Rabinovitch, B.1    March, W.F.2    Adams, R.L.3
  • 11
    • 0020055939 scopus 로고
    • Noninvasive glucose monitoring of the aqueous humor of the eye: Part II. Animal studies and the scleral lens
    • March WF, Rabinovitch B, Adams RL. Noninvasive glucose monitoring of the aqueous humor of the eye: Part II. Animal studies and the scleral lens. Diabetes Care. 1982;5(3):259-65.
    • (1982) Diabetes Care , vol.5 , Issue.3 , pp. 259-265
    • March, W.F.1    Rabinovitch, B.2    Adams, R.L.3
  • 12
    • 0026891886 scopus 로고
    • Noninvasive optical polarimetric glucose sensing using a true phase measurement technique
    • Coté GL, Fox MD, Northrop RB. Noninvasive optical polarimetric glucose sensing using a true phase measurement technique. IEEE Trans Biomed Eng. 1992;39(7):752-6.
    • (1992) IEEE Trans Biomed Eng , vol.39 , Issue.7 , pp. 752-756
    • Coté, G.L.1    Fox, M.D.2    Northrop, R.B.3
  • 13
    • 0028493491 scopus 로고
    • Multispectral polarimetric glucose detection using a single Pockels cell
    • King TW, Coté GL, McNichols R, Goetz MJ. Multispectral polarimetric glucose detection using a single Pockels cell. Opt Eng. 1994;33(8):2746-53.
    • (1994) Opt Eng , vol.33 , Issue.8 , pp. 2746-2753
    • King, T.W.1    Coté, G.L.2    McNichols, R.3    Goetz, M.J.4
  • 15
    • 9144226950 scopus 로고    scopus 로고
    • Metal-enhanced fluorescence solution-based sensing platform
    • Aslan K, Lakowicz JR, Szmacinski H, Geddes CD. Metal-enhanced fluorescence solution-based sensing platform. J Fluoresc. 2004;14(6):677-9.
    • (2004) J Fluoresc , vol.14 , Issue.6 , pp. 677-679
    • Aslan, K.1    Lakowicz, J.R.2    Szmacinski, H.3    Geddes, C.D.4
  • 16
    • 75849122877 scopus 로고    scopus 로고
    • Microfluidic devices integrating microcavity surface-plasmon-resonance sensors: Glucose oxidase binding-activity detection
    • Amarie D, Alileche A, Dragnea B, Glazier JA. Microfluidic devices integrating microcavity surface-plasmon-resonance sensors: glucose oxidase binding-activity detection. Anal Chem. 2010;82(1):343-52.
    • (2010) Anal Chem , vol.82 , Issue.1 , pp. 343-352
    • Amarie, D.1    Alileche, A.2    Dragnea, B.3    Glazier, J.A.4
  • 17
    • 62449126447 scopus 로고    scopus 로고
    • Glucose sensors: A review of current and emerging technology
    • Oliver NS, Toumazou C, Cass AE, Johnston DG. Glucose sensors: a review of current and emerging technology. Diabet Med. 2009;26(3):197-210.
    • (2009) Diabet Med , vol.26 , Issue.3 , pp. 197-210
    • Oliver, N.S.1    Toumazou, C.2    Cass, A.E.3    Johnston, D.G.4
  • 18
    • 0141516162 scopus 로고    scopus 로고
    • New developments in home glucose monitoring: Minimizing the pain
    • Gabbay RA. New developments in home glucose monitoring: minimizing the pain. Can J Diabetes. 2003;27(3):271-6.
    • (2003) Can J Diabetes , vol.27 , Issue.3 , pp. 271-276
    • Gabbay, R.A.1
  • 19
    • 0018258681 scopus 로고
    • Role of tears in maintaining corneal integrity
    • Tiffany JM, Bron AJ. Role of tears in maintaining corneal integrity. Trans Ophthalmol Soc UK. 1978;98(3):335-8.
    • (1978) Trans Ophthalmol Soc UK , vol.98 , Issue.3 , pp. 335-338
    • Tiffany, J.M.1    Bron, A.J.2
  • 20
    • 26844432009 scopus 로고    scopus 로고
    • Analysis of human tear fluid by Fourier transform infrared spectroscopy
    • Nagase Y, Yoshida S, Kamiyama K. Analysis of human tear fluid by Fourier transform infrared spectroscopy. Biopolymers. 2005;79(1):18-27.
    • (2005) Biopolymers , vol.79 , Issue.1 , pp. 18-27
    • Nagase, Y.1    Yoshida, S.2    Kamiyama, K.3
  • 21
    • 33646895865 scopus 로고    scopus 로고
    • Laboratory findings in tear fluid analysis
    • Ohashi Y, Dogru M, Tsubota K. Laboratory findings in tear fluid analysis. Clin Chim Acta. 2006;369(1):17-28.
    • (2006) Clin Chim Acta , vol.369 , Issue.1 , pp. 17-28
    • Ohashi, Y.1    Dogru, M.2    Tsubota, K.3
  • 22
    • 0038490752 scopus 로고
    • Safety requirements for acrylic implants
    • Ridley F. Safety requirements for acrylic implants. Br J Exp Pathol. 1957;41:359-69.
    • (1957) Br J Exp Pathol , vol.41 , pp. 359-369
    • Ridley, F.1
  • 23
    • 81155147804 scopus 로고
    • Recherches sur les taux de glucose dans les larmes chez les sujets normaux et diabetiques
    • Giardini A. Recherches sur les taux de glucose dans les larmes chez les sujets normaux et diabetiques. Boll Oculist. 1948;27:585-99.
    • (1948) Boll Oculist , vol.27 , pp. 585-599
    • Giardini, A.1
  • 25
    • 0343922732 scopus 로고
    • Concentration of glucose and total chloride in tears
    • Giardini A, Roberts JR. Concentration of glucose and total chloride in tears. Br J Ophthalmol. 1950;34(12):737-43.
    • (1950) Br J Ophthalmol , vol.34 , Issue.12 , pp. 737-743
    • Giardini, A.1    Roberts, J.R.2
  • 26
    • 0346894082 scopus 로고
    • Sur l'elimination lacrymale du glucose chez les diabetiques
    • Michail D, Vancea P, Zolog N. Sur l'elimination lacrymale du glucose chez les diabetiques. C R Soc Biol. 1937;125:1095.
    • (1937) C R Soc Biol , vol.125 , pp. 1095
    • Michail, D.1    Vancea, P.2    Zolog, N.3
  • 27
    • 0019426669 scopus 로고
    • Clinical biochemistry of tears
    • Van Haeringen NJ. Clinical biochemistry of tears. Surv Ophthalmol. 1981;26(2):84-96.
    • (1981) Surv Ophthalmol , vol.26 , Issue.2 , pp. 84-96
    • Van Haeringen, N.J.1
  • 29
    • 0346764296 scopus 로고
    • Tear glucose in diabetics
    • Lewis JG, Stephens PJ. Tear glucose in diabetics. Br J Ophthalmol. 1958;42(12):754-8.
    • (1958) Br J Ophthalmol , vol.42 , Issue.12 , pp. 754-758
    • Lewis, J.G.1    Stephens, P.J.2
  • 31
    • 1542612124 scopus 로고
    • The glucose content of the tear fluid in normal and diabetic subjects
    • Motoji K. The glucose content of the tear fluid in normal and diabetic subjects. Jpn J Clin Ophthalmol. 1971;25:1945-50.
    • (1971) Jpn J Clin Ophthalmol , vol.25 , pp. 1945-1950
    • Motoji, K.1
  • 32
    • 0018967308 scopus 로고
    • Tear glucose levels in normal people and in diabetic patients
    • Sen DK, Sarin GS. Tear glucose levels in normal people and in diabetic patients. Br J Ophthalmol. 1980;64(9):693-5.
    • (1980) Br J Ophthalmol , vol.64 , Issue.9 , pp. 693-695
    • Sen, D.K.1    Sarin, G.S.2
  • 35
    • 46149089209 scopus 로고    scopus 로고
    • Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus
    • Baca JT, Finegold DN, Asher SA. Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus. Ocul Surf. 2007;5(4):208-93.
    • (2007) Ocul Surf , vol.5 , Issue.4 , pp. 208-293
    • Baca, J.T.1    Finegold, D.N.2    Asher, S.A.3
  • 36
    • 0028356467 scopus 로고
    • Collection and concentration of tear proteins studied by SDS gel electrophoresis. Presentation of a new method with special reference to dry eye patients
    • Bjerrum KB, Prause JU. Collection and concentration of tear proteins studied by SDS gel electrophoresis. Presentation of a new method with special reference to dry eye patients. Graefes Arch Clin Exp Ophthalmol. 1994;232(7):402-5.
    • (1994) Graefes Arch Clin Exp Ophthalmol , vol.232 , Issue.7 , pp. 402-405
    • Bjerrum, K.B.1    Prause, J.U.2
  • 37
    • 0022499424 scopus 로고
    • The presence of a contact lens induces a very small change in the anterior corneal surface temperature
    • Copenh
    • Martin D, Fatt I. The presence of a contact lens induces a very small change in the anterior corneal surface temperature. Acta Ophthal (Copenh). 1986;64(5):512-8.
    • (1986) Acta Ophthal , vol.64 , Issue.5 , pp. 512-518
    • Martin, D.1    Fatt, I.2
  • 38
    • 79953016913 scopus 로고    scopus 로고
    • Modeling the corneal birefringence of the eye toward the development of a polarimetric glucose sensor
    • Malik BH, Coté GL. Modeling the corneal birefringence of the eye toward the development of a polarimetric glucose sensor. J Biomed Opt. 2010;15(3):037012-8.
    • (2010) J Biomed Opt , vol.15 , Issue.3 , pp. 037012-037018
    • Malik, B.H.1    Coté, G.L.2
  • 39
    • 0035147289 scopus 로고    scopus 로고
    • A prospective study of contact lens wear in diabetes mellitus
    • O'Donnell C, Efron N, Boulton AJ. A prospective study of contact lens wear in diabetes mellitus. Ophthalmic Physiol Opt. 2001;21(2):127-38.
    • (2001) Ophthalmic Physiol Opt , vol.21 , Issue.2 , pp. 127-138
    • O'Donnell, C.1    Efron, N.2    Boulton, A.J.3
  • 41
    • 9244233374 scopus 로고    scopus 로고
    • Photonic crystal glucose-sensing material for noninvasive monitoring of glucose in tear fluid
    • Alexeev VL, Das S, Finegold DN, Asher SA. Photonic crystal glucose-sensing material for noninvasive monitoring of glucose in tear fluid. Clin Chem 2004;50(12):2353-60.
    • (2004) Clin Chem , vol.50 , Issue.12 , pp. 2353-2360
    • Alexeev, V.L.1    Das, S.2    Finegold, D.N.3    Asher, S.A.4
  • 42
    • 9144227561 scopus 로고    scopus 로고
    • Wavelength-ratiometric probes for the selective detection of fluoride based on the 6-amino-quinolinium nucleus and boronic acid moiety
    • Badugu R, Lakowicz JR, Geddes CD. Wavelength-ratiometric probes for the selective detection of fluoride based on the 6-amino-quinolinium nucleus and boronic acid moiety. J Fluoresc. 2004;14(6): 693-703.
    • (2004) J Fluoresc , vol.14 , Issue.6 , pp. 693-703
    • Badugu, R.1    Lakowicz, J.R.2    Geddes, C.D.3
  • 43
    • 53249105860 scopus 로고    scopus 로고
    • Chemical biology: Past, present and future
    • Sekhon BS. Chemical biology: past, present and future. Current Chem Bio. 2008;2(3):278-311.
    • (2008) Current Chem Bio , vol.2 , Issue.3 , pp. 278-311
    • Sekhon, B.S.1
  • 45
    • 33747349486 scopus 로고    scopus 로고
    • Concanavalin A for in vivo glucose sensing: A biotoxicity review
    • Ballerstadt R, Evans C, McNichols R, Gowda A. Concanavalin A for in vivo glucose sensing: a biotoxicity review. Biosens Bioelectron. 2006;22(2):275-84.
    • (2006) Biosens Bioelectron , vol.22 , Issue.2 , pp. 275-284
    • Ballerstadt, R.1    Evans, C.2    McNichols, R.3    Gowda, A.4
  • 46
    • 0033764715 scopus 로고    scopus 로고
    • Wavelength-shifting molecular beacons
    • Tyagi S, Marras SA, Kramer FR. Wavelength-shifting molecular beacons. Nat Biotechnol. 2000;18(11):1191-6.
    • (2000) Nat Biotechnol , vol.18 , Issue.11 , pp. 1191-1196
    • Tyagi, S.1    Marras, S.A.2    Kramer, F.R.3
  • 47
    • 84857796426 scopus 로고    scopus 로고
    • Contact lens integrated with a biosensor for the detection of glucose and other components in tears
    • US patent No. 20100113901; Canadian patent No. 886171024
    • Zhang J, Hodge W. Contact lens integrated with a biosensor for the detection of glucose and other components in tears. US patent No. 20100113901; Canadian patent No. 886171024.
    • Zhang, J.1    Hodge, W.2
  • 48
    • 77958516026 scopus 로고    scopus 로고
    • Dendritic cell internalization of foam-structured fluorescent mesoporous silica nanoparticles
    • Mumin AM, Barrett JW, Dekaban GA, Zhang J. Dendritic cell internalization of foam-structured fluorescent mesoporous silica nanoparticles. J Colloid Interface Sci. 2011;353(1):156-62.
    • (2011) J Colloid Interface Sci , vol.353 , Issue.1 , pp. 156-162
    • Mumin, A.M.1    Barrett, J.W.2    Dekaban, G.A.3    Zhang, J.4
  • 51


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.