메뉴 건너뛰기




Volumn 46, Issue 16, 2007, Pages 3359-3368

Feasibility analysis of an epidermal glucose sensor based on time-resolved fluorescence

Author keywords

[No Author keywords available]

Indexed keywords

COLLAGEN; FLUOROPHORES; MULTILAYERS; QUANTUM YIELD; RADIATIVE TRANSFER;

EID: 34547311895     PISSN: 1559128X     EISSN: 15394522     Source Type: Journal    
DOI: 10.1364/AO.46.003359     Document Type: Article
Times cited : (6)

References (47)
  • 1
    • 14644392814 scopus 로고    scopus 로고
    • In vivo glucose monitoring: The clinical reality and the promise
    • J. Pickup, F. Hussain, N. Evans, and N. Sachedina, "In vivo glucose monitoring: the clinical reality and the promise," Biosens. Bioelectron. 20, 1897-902 (2005).
    • (2005) Biosens. Bioelectron , vol.20 , pp. 1897-1902
    • Pickup, J.1    Hussain, F.2    Evans, N.3    Sachedina, N.4
  • 2
    • 0030345433 scopus 로고    scopus 로고
    • Quantitative optical spectroscopy for tissue diagnostics
    • R. Richards-Kortum and E. Sevick-Muraca, "Quantitative optical spectroscopy for tissue diagnostics," Ann. Rev. Phys. Chem. 47, 555-606 (1996).
    • (1996) Ann. Rev. Phys. Chem , vol.47 , pp. 555-606
    • Richards-Kortum, R.1    Sevick-Muraca, E.2
  • 4
    • 0034111367 scopus 로고    scopus 로고
    • Monte Carlo modeling for implantable fluorescent analyte sensors
    • M. McShane, S. Rastegar, M. Pishko, and G. Cote, "Monte Carlo modeling for implantable fluorescent analyte sensors," IEEE Trans. Biomed. Eng. 47, 624-632 (2000).
    • (2000) IEEE Trans. Biomed. Eng , vol.47 , pp. 624-632
    • McShane, M.1    Rastegar, S.2    Pishko, M.3    Cote, G.4
  • 5
    • 0034865232 scopus 로고    scopus 로고
    • Implantable biosensors: Analysis of fluorescent light propagation through skin
    • D. P. O'Neal, M. J. McShane, M. V. Pishko, and G. L. Cote, "Implantable biosensors: analysis of fluorescent light propagation through skin," Proc. SPIE 4263, 20-24 (2001).
    • (2001) Proc. SPIE , vol.4263 , pp. 20-24
    • O'Neal, D.P.1    McShane, M.J.2    Pishko, M.V.3    Cote, G.L.4
  • 6
    • 0035879464 scopus 로고    scopus 로고
    • Evaluation of two synthetic glucose probes for fluorescence-lifetime-based sensing
    • N. DiCesare and J. R. Lakowicz, "Evaluation of two synthetic glucose probes for fluorescence-lifetime-based sensing," Anal. Biochem. 294, 154-160 (2001).
    • (2001) Anal. Biochem , vol.294 , pp. 154-160
    • DiCesare, N.1    Lakowicz, J.R.2
  • 8
    • 84975551241 scopus 로고
    • Fluorescence spectroscopy of turbid media: Autofluorescence of the human aorta
    • M. Keijzer, R. Richards-Kortum, S. Jacques, and M. Feld, "Fluorescence spectroscopy of turbid media: autofluorescence of the human aorta," Appl. Opt. 28, 4286-4292 (1989).
    • (1989) Appl. Opt , vol.28 , pp. 4286-4292
    • Keijzer, M.1    Richards-Kortum, R.2    Jacques, S.3    Feld, M.4
  • 9
    • 1342310479 scopus 로고    scopus 로고
    • A novel Monte Carlo method for the optical diagnostics of skin
    • I. V. Meglinski and D. Y. Churmakov, "A novel Monte Carlo method for the optical diagnostics of skin," Proc. SPIE 5141, 133-141 (2003).
    • (2003) Proc. SPIE , vol.5141 , pp. 133-141
    • Meglinski, I.V.1    Churmakov, D.Y.2
  • 10
    • 1842424694 scopus 로고    scopus 로고
    • Monte Carlo method in optical diagnostics of skin and skin tissues
    • I. V. Meglinski, "Monte Carlo method in optical diagnostics of skin and skin tissues," Proc. SPIE 5254, 30-43 (2003).
    • (2003) Proc. SPIE , vol.5254 , pp. 30-43
    • Meglinski, I.V.1
  • 11
    • 80855160073 scopus 로고
    • Monte Carlo modeling of tissue autofluorescence measurement and imaging
    • H. Zeng, C. E. MacAulay, B. Palcic, and D. I. McLean, "Monte Carlo modeling of tissue autofluorescence measurement and imaging," Proc. SPIE 2135, 94-104 (1994).
    • (1994) Proc. SPIE , vol.2135 , pp. 94-104
    • Zeng, H.1    MacAulay, C.E.2    Palcic, B.3    McLean, D.I.4
  • 12
    • 0037152060 scopus 로고    scopus 로고
    • Quantitative fluorescence lifetime spectroscopy in turbid media: Comparison of theoretical, experimental and computational methods
    • K. Vishwanath, B. Pogue, and M.-A. Mycek, "Quantitative fluorescence lifetime spectroscopy in turbid media: comparison of theoretical, experimental and computational methods," Phys. Med. Biol. 47, 3387-3405 (2002).
    • (2002) Phys. Med. Biol , vol.47 , pp. 3387-3405
    • Vishwanath, K.1    Pogue, B.2    Mycek, M.-A.3
  • 13
    • 0345282984 scopus 로고    scopus 로고
    • Simulations of time-resolved fluorescence in multilayered biological tissues: Applications to clinical data modeling
    • M.-A. Mycek, K. Vishwanath, B. W. Pogue, K. T. Schomacker, and N. S. Nishioka, "Simulations of time-resolved fluorescence in multilayered biological tissues: applications to clinical data modeling," Proc. SPIE 4958, 51-59 (2003).
    • (2003) Proc. SPIE , vol.4958 , pp. 51-59
    • Mycek, M.-A.1    Vishwanath, K.2    Pogue, B.W.3    Schomacker, K.T.4    Nishioka, N.S.5
  • 14
    • 3142681799 scopus 로고    scopus 로고
    • Do fluorescence decays remitted from tissues accurately reflect intrinsic fluorophore life-times?
    • K. Vishwanath and M.-A. Mycek, "Do fluorescence decays remitted from tissues accurately reflect intrinsic fluorophore life-times?" Opt. Lett. 29, 1512-1514 (2004).
    • (2004) Opt. Lett , vol.29 , pp. 1512-1514
    • Vishwanath, K.1    Mycek, M.-A.2
  • 15
    • 0028421474 scopus 로고
    • Mathematical model for time-resolved and frequency-domain fluorescence spectroscopy in biological tissues
    • M. S. Patterson and B. W. Pogue, "Mathematical model for time-resolved and frequency-domain fluorescence spectroscopy in biological tissues," Appl. Opt. 33, 1963-1974 (1994).
    • (1994) Appl. Opt , vol.33 , pp. 1963-1974
    • Patterson, M.S.1    Pogue, B.W.2
  • 17
    • 7344240095 scopus 로고    scopus 로고
    • Imaging of fluorescence yield and lifetime from multiply scattered light re-emitted from random media
    • E. M. Sevick-Muraca and D. Y. Paithankar, "Imaging of fluorescence yield and lifetime from multiply scattered light re-emitted from random media," Proc. SPIE 2980, 303-318 (1997).
    • (1997) Proc. SPIE , vol.2980 , pp. 303-318
    • Sevick-Muraca, E.M.1    Paithankar, D.Y.2
  • 18
    • 0000845709 scopus 로고    scopus 로고
    • Imaging of fluorescent yield and lifetime from multiply scattered light reemitted from random media
    • D. Y. Paithankar, A. U. Chen, B. W. Pogue, M. S. Patterson, and E. M. Sevick-Muraca, "Imaging of fluorescent yield and lifetime from multiply scattered light reemitted from random media," Appl. Opt. 36, 2260-2272 (1997).
    • (1997) Appl. Opt , vol.36 , pp. 2260-2272
    • Paithankar, D.Y.1    Chen, A.U.2    Pogue, B.W.3    Patterson, M.S.4    Sevick-Muraca, E.M.5
  • 19
    • 0031901460 scopus 로고    scopus 로고
    • Comparison of finite-difference transport and diffusion calculations for photon migration in homogeneous and heterogeneous tissues
    • A. H. Hielscher, R. E. Alcouffe, and R. L. Barbour, "Comparison of finite-difference transport and diffusion calculations for photon migration in homogeneous and heterogeneous tissues," Phys. Med. Biol. 43, 1285-1302 (1998).
    • (1998) Phys. Med. Biol , vol.43 , pp. 1285-1302
    • Hielscher, A.H.1    Alcouffe, R.E.2    Barbour, R.L.3
  • 20
    • 0013133757 scopus 로고    scopus 로고
    • Validity of the diffusion approximation in bio-optical imaging
    • B. Chen, K. Stamnes, and J. J. Stamnes, "Validity of the diffusion approximation in bio-optical imaging," Appl. Opt. 40, 6536-6366 (2001).
    • (2001) Appl. Opt , vol.40 , pp. 6536-6366
    • Chen, B.1    Stamnes, K.2    Stamnes, J.J.3
  • 21
    • 0030913067 scopus 로고    scopus 로고
    • Reconstruction of in vivo skin autofluorescence spectrum from microscopic properties by Monte Carlo simulation
    • H. Zeng, C. MacAulay, D. I. McLean, and B. Palcic, "Reconstruction of in vivo skin autofluorescence spectrum from microscopic properties by Monte Carlo simulation," J. Photochem. Photobiol. B 38, 234-240 (1997).
    • (1997) J. Photochem. Photobiol. B , vol.38 , pp. 234-240
    • Zeng, H.1    MacAulay, C.2    McLean, D.I.3    Palcic, B.4
  • 22
    • 0033774120 scopus 로고    scopus 로고
    • Fluorescence excitation spectroscopy provides information about human skin in vivo
    • R. Gillies, G. Zonios, R. R. Anderson, and N. Kollias, "Fluorescence excitation spectroscopy provides information about human skin in vivo," J. Investig. Dermatol. 115, 704-707 (2000).
    • (2000) J. Investig. Dermatol , vol.115 , pp. 704-707
    • Gillies, R.1    Zonios, G.2    Anderson, R.R.3    Kollias, N.4
  • 23
    • 29244473864 scopus 로고    scopus 로고
    • Modified method of characteristics in transient radiative transfer
    • K. Katika and L. Pilon, "Modified method of characteristics in transient radiative transfer," J. Quant. Spectrosc. Radiat. Transfer 98, 220-237 (2006).
    • (2006) J. Quant. Spectrosc. Radiat. Transfer , vol.98 , pp. 220-237
    • Katika, K.1    Pilon, L.2
  • 24
    • 33746163374 scopus 로고    scopus 로고
    • Steady-state directional diffuse reflectance and fluorescence of human skin
    • K. Katika and L. Pilon, "Steady-state directional diffuse reflectance and fluorescence of human skin," Appl. Opt. 45, 4174-4183 (2006).
    • (2006) Appl. Opt , vol.45 , pp. 4174-4183
    • Katika, K.1    Pilon, L.2
  • 25
    • 0030784198 scopus 로고    scopus 로고
    • Fast fitting of multi-exponential decay curves
    • J. Enderlein and R. Erdmann, "Fast fitting of multi-exponential decay curves," Opt. Commun. 134, 371-378 (1997).
    • (1997) Opt. Commun , vol.134 , pp. 371-378
    • Enderlein, J.1    Erdmann, R.2
  • 26
    • 84893993407 scopus 로고    scopus 로고
    • Fluofit, a MATLAB package for fitting multiexponential fluorescence decay curves, last accessed 22 December 2005
    • "Fluofit - a MATLAB package for fitting multiexponential fluorescence decay curves," http://www.fz-juelich.de/ibi/ibi-1/enderlein/ joerg/fluo/fluo.html, last accessed 22 December 2005.
  • 28
    • 33646176421 scopus 로고    scopus 로고
    • Monte Carlo method in optical diagnostics of skin and skin tissues
    • I. V. Meglinski and S. J. Matcher, "Monte Carlo method in optical diagnostics of skin and skin tissues," Proc. SPIE 4241, 78-87 (2001).
    • (2001) Proc. SPIE , vol.4241 , pp. 78-87
    • Meglinski, I.V.1    Matcher, S.J.2
  • 29
    • 4644232655 scopus 로고    scopus 로고
    • A Study on SkinOptics
    • Technical Report CS-2004-01 School of Computer Science, University of Waterloo
    • A. Krishnaswamy and G. V. G. Baranoski, A Study on SkinOptics, Technical Report CS-2004-01 (School of Computer Science, University of Waterloo, 2004).
    • (2004)
    • Krishnaswamy, A.1    Baranoski, G.V.G.2
  • 32
    • 2942724476 scopus 로고    scopus 로고
    • Fast 3-D optical imaging with transient fluorescence signals
    • H. Quan and Z. Guo, "Fast 3-D optical imaging with transient fluorescence signals," Opt. Express 12, 449-457 (2004).
    • (2004) Opt. Express , vol.12 , pp. 449-457
    • Quan, H.1    Guo, Z.2
  • 34
    • 0000055253 scopus 로고    scopus 로고
    • Modeling of the roughinterface effect on a converging light beam propagating in a skin tissue phantom
    • J. Q. Lu, X.-H. Hu, and K. Dong, "Modeling of the roughinterface effect on a converging light beam propagating in a skin tissue phantom," Appl. Opt. 39, 5890-5897 (2000).
    • (2000) Appl. Opt , vol.39 , pp. 5890-5897
    • Lu, J.Q.1    Hu, X.-H.2    Dong, K.3
  • 35
    • 0141644208 scopus 로고    scopus 로고
    • High-resolution multiphoton to-mography of human skin with subcellular spatial resolution and picosecond time resolution
    • K. König and I. Riemann, "High-resolution multiphoton to-mography of human skin with subcellular spatial resolution and picosecond time resolution," J. Biomed. Opt. 8, 432-439 (2003).
    • (2003) J. Biomed. Opt , vol.8 , pp. 432-439
    • König, K.1    Riemann, I.2
  • 36
    • 0035395713 scopus 로고    scopus 로고
    • Design and development of a rapid acquisition laser-based fluorometer with simultaneous spectral and temporal resolution
    • J. D. Pitts and M.-A. Mycek, "Design and development of a rapid acquisition laser-based fluorometer with simultaneous spectral and temporal resolution," Rev. Sci. Instrum. 72, 3061-3072 (2001).
    • (2001) Rev. Sci. Instrum , vol.72 , pp. 3061-3072
    • Pitts, J.D.1    Mycek, M.-A.2
  • 37
    • 0026891886 scopus 로고
    • Noninvasive optical polarimetric glucose sensing using a true phase measurement technique
    • G. L. Cote, M. D. Fox, and R. B. Northrop, "Noninvasive optical polarimetric glucose sensing using a true phase measurement technique," IEEE Trans. Biomed. Eng. 39, 752-756 (1992).
    • (1992) IEEE Trans. Biomed. Eng , vol.39 , pp. 752-756
    • Cote, G.L.1    Fox, M.D.2    Northrop, R.B.3
  • 38
    • 0033329779 scopus 로고    scopus 로고
    • In-vivo NIR diffusereflectance tissue spectroscopy of human subjects
    • G. W. Hopkins and G. R. Mauze, "In-vivo NIR diffusereflectance tissue spectroscopy of human subjects," Proc. SPIE 3597, 632-641 (1999).
    • (1999) Proc. SPIE , vol.3597 , pp. 632-641
    • Hopkins, G.W.1    Mauze, G.R.2
  • 39
    • 0343340061 scopus 로고    scopus 로고
    • Propagation of scattered radiation in a participating planar medium with pulse irradiation
    • C.-Y. Wu, "Propagation of scattered radiation in a participating planar medium with pulse irradiation," J. Quant. Spectrosc. Radiat. Transfer 64, 537-548 (2000).
    • (2000) J. Quant. Spectrosc. Radiat. Transfer , vol.64 , pp. 537-548
    • Wu, C.-Y.1
  • 40
    • 0345873338 scopus 로고    scopus 로고
    • Measurements of radiation characteristics of fused quartz containing bubbles
    • D. Baillis, L. Pilon, H. Randrianalisoa, R. Gomez, and R. Viskanta, "Measurements of radiation characteristics of fused quartz containing bubbles," J. Opt. Soc. Am. A 21, 149-159 (2004).
    • (2004) J. Opt. Soc. Am. A , vol.21 , pp. 149-159
    • Baillis, D.1    Pilon, L.2    Randrianalisoa, H.3    Gomez, R.4    Viskanta, R.5
  • 41
    • 34547256799 scopus 로고    scopus 로고
    • Comments on Fluofit and fitting fluorescence decay curves, Institute of Analytical Chemistry, Chemo- und Biosensors, University of Regensburg, PF 10 10 42, D-93040 Regensburg, Germany personal communication
    • J. Enderlein, "Comments on Fluofit and fitting fluorescence decay curves," Institute of Analytical Chemistry, Chemo- und Biosensors, University of Regensburg, PF 10 10 42, D-93040 Regensburg, Germany (personal communication, 2006).
    • (2006)
    • Enderlein, J.1
  • 43
    • 0029583968 scopus 로고
    • The influence of boundary conditions on the accuracy of diffusion theory in time-resolved reflectance spectroscopy of biological tissues
    • A. Hielscher, S. Jacques, L. Wang, and F. Tittel, "The influence of boundary conditions on the accuracy of diffusion theory in time-resolved reflectance spectroscopy of biological tissues," Phys. Med. Biol. 40, 1957-1975 (1995).
    • (1995) Phys. Med. Biol , vol.40 , pp. 1957-1975
    • Hielscher, A.1    Jacques, S.2    Wang, L.3    Tittel, F.4
  • 44
    • 2442715344 scopus 로고    scopus 로고
    • Amending of fluorescence sensor signal localization in human skin by matching of the refractive index
    • D. Y. Churmakov, I. V. Meglinski, and D. A. Greenhalgh, "Amending of fluorescence sensor signal localization in human skin by matching of the refractive index," J. Biomed. Opt. 9, 339-346 (2004).
    • (2004) J. Biomed. Opt , vol.9 , pp. 339-346
    • Churmakov, D.Y.1    Meglinski, I.V.2    Greenhalgh, D.A.3
  • 46
    • 6344231782 scopus 로고    scopus 로고
    • Noninvasive, optical detection of diabetes: Model studies with porcine skin
    • E. Hull, M. Ediger, A. Unione, E. Deemer, M. Stroman, and J. Baynes, "Noninvasive, optical detection of diabetes: model studies with porcine skin," Opt. Express 12, 4496-4510 (2004).
    • (2004) Opt. Express , vol.12 , pp. 4496-4510
    • Hull, E.1    Ediger, M.2    Unione, A.3    Deemer, E.4    Stroman, M.5    Baynes, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.