-
1
-
-
46349091062
-
Failure of impedance monitoring to prevent adverse clinical events caused by fracture of a recalled high-voltage implantable cardioverter-defibrillator lead
-
L.M. Kallinen, R.G. Hauser, and K.W. Lee Failure of impedance monitoring to prevent adverse clinical events caused by fracture of a recalled high-voltage implantable cardioverter-defibrillator lead Heart Rhythm 5 2008 775 779
-
(2008)
Heart Rhythm
, vol.5
, pp. 775-779
-
-
Kallinen, L.M.1
Hauser, R.G.2
Lee, K.W.3
-
2
-
-
42649141945
-
Outcome of the Fidelis implantable cardioverter-defibrillator lead advisory: A report from the Canadian Heart Rhythm Society Device Advisory Committee
-
A.D. Krahn, J. Champagne, and J.S. Healey Outcome of the Fidelis implantable cardioverter-defibrillator lead advisory: a report from the Canadian Heart Rhythm Society Device Advisory Committee Heart Rhythm 5 2008 639 642
-
(2008)
Heart Rhythm
, vol.5
, pp. 639-642
-
-
Krahn, A.D.1
Champagne, J.2
Healey, J.S.3
-
3
-
-
57449108890
-
Downloadable algorithm to reduce inappropriate shocks caused by fractures of implantable cardioverter-defibrillator leads
-
C.D. Swerdlow, B.D. Gunderson, and K.T. Ousdigian Downloadable algorithm to reduce inappropriate shocks caused by fractures of implantable cardioverter-defibrillator leads Circulation 118 2008 2122 2129
-
(2008)
Circulation
, vol.118
, pp. 2122-2129
-
-
Swerdlow, C.D.1
Gunderson, B.D.2
Ousdigian, K.T.3
-
4
-
-
77956796268
-
Lead integrity alert algorithm decreases inappropriate shocks in patients who have Sprint Fidelis pace-sense conductor fractures
-
L.M. Kallinen, R.G. Hauser, and C. Tang Lead integrity alert algorithm decreases inappropriate shocks in patients who have Sprint Fidelis pace-sense conductor fractures Heart Rhythm 7 2010 1048 1055
-
(2010)
Heart Rhythm
, vol.7
, pp. 1048-1055
-
-
Kallinen, L.M.1
Hauser, R.G.2
Tang, C.3
-
5
-
-
77953362866
-
Complications associated with revision of Sprint Fidelis leads: Report from the Canadian Heart Rhythm Society Device Advisory Committee
-
R. Parkash, E. Crystal, and J. Bashir Complications associated with revision of Sprint Fidelis leads: report from the Canadian Heart Rhythm Society Device Advisory Committee Circulation 121 2010 2384 2387
-
(2010)
Circulation
, vol.121
, pp. 2384-2387
-
-
Parkash, R.1
Crystal, E.2
Bashir, J.3
-
6
-
-
62549164259
-
The changing presentation of implantable cardioverter-defibrillator lead fractures
-
C.D. Swerdlow, and K.A. Ellenbogen The changing presentation of implantable cardioverter-defibrillator lead fractures Heart Rhythm 6 2009 478 479
-
(2009)
Heart Rhythm
, vol.6
, pp. 478-479
-
-
Swerdlow, C.D.1
Ellenbogen, K.A.2
-
7
-
-
0036955622
-
Automatic identification of implantable cardioverter-defibrillator lead problems using intracardiac electrograms
-
B. Gunderson, A. Patel, and C. Bounds Automatic identification of implantable cardioverter-defibrillator lead problems using intracardiac electrograms Comput Cardiol Proc 29 2002 121 124
-
(2002)
Comput Cardiol Proc
, vol.29
, pp. 121-124
-
-
Gunderson, B.1
Patel, A.2
Bounds, C.3
-
8
-
-
77956828284
-
Causes of ventricular oversensing in implantable cardioverter- defibrillators: Implications for diagnosis of lead fracture
-
B.D. Gunderson, C.D. Swerdlow, J.M. Wilcox, J.E. Hayman, K.T. Ousdigian, and K.A. Ellenbogen Causes of ventricular oversensing in implantable cardioverter-defibrillators: implications for diagnosis of lead fracture Heart Rhythm 7 2010 626 633
-
(2010)
Heart Rhythm
, vol.7
, pp. 626-633
-
-
Gunderson, B.D.1
Swerdlow, C.D.2
Wilcox, J.M.3
Hayman, J.E.4
Ousdigian, K.T.5
Ellenbogen, K.A.6
-
9
-
-
48749106819
-
Implantable cardiac defibrillator lead failure or myopotential oversensing?: An approach to the diagnosis of noise on lead electrograms
-
M. Kowalski, K.A. Ellenbogen, M.A. Wood, and P.L. Friedman Implantable cardiac defibrillator lead failure or myopotential oversensing? An approach to the diagnosis of noise on lead electrograms Europace 10 2008 914 917
-
(2008)
Europace
, vol.10
, pp. 914-917
-
-
Kowalski, M.1
Ellenbogen, K.A.2
Wood, M.A.3
Friedman, P.L.4
-
10
-
-
4644363722
-
Implantable cardioverter-defibrillator malfunction due to mechanical failure of the header connection
-
DOI 10.1046/j.1540-8167.2004.03682.x
-
R.A. Pickett 3rd, P. Saavedra, M.F. Ali, D. Darbar, and J.N. Rottman Implantable cardioverter-defibrillator malfunction due to mechanical failure of the header connection J Cardiovasc Electrophysiol 15 2004 1095 1099 (Pubitemid 39281543)
-
(2004)
Journal of Cardiovascular Electrophysiology
, vol.15
, Issue.9
, pp. 1095-1099
-
-
Pickett III, R.A.1
Saavedra, P.2
Ali, M.F.3
Darbar, D.4
Rottman, J.N.5
-
11
-
-
7044237094
-
An algorithm to predict implantable cardioverter-defibrillator lead failure
-
DOI 10.1016/j.jacc.2004.07.042, PII S0735109704016109
-
B.D. Gunderson, A.S. Patel, C.A. Bounds, R.K. Shepard, M.A. Wood, and K.A. Ellenbogen An algorithm to predict implantable cardioverter-defibrillator lead failure J Am Coll Cardiol 44 2004 1898 1902 (Pubitemid 39424093)
-
(2004)
Journal of the American College of Cardiology
, vol.44
, Issue.9
, pp. 1898-1902
-
-
Gunderson, B.D.1
Patel, A.S.2
Bounds, C.A.3
Shepard, R.K.4
Wood, M.A.5
Ellenbogen, K.A.6
-
12
-
-
30344441831
-
Shock-induced ventricular oversensing due to seal plug damage: A potential mechanism of inappropriate device therapies in implantable cardioverter-defibrillators
-
DOI 10.1016/j.hrthm.2005.09.005, PII S1547527105020291
-
J.W. Cheung, S. Iwai, B.B. Lerman, and S. Mittal Shock-induced ventricular oversensing due to seal plug damage: a potential mechanism of inappropriate device therapies in implantable cardioverter-defibrillators Heart Rhythm 2 2005 1371 1375 (Pubitemid 43055424)
-
(2005)
Heart Rhythm
, vol.2
, Issue.12
, pp. 1371-1375
-
-
Cheung, J.W.1
Iwai, S.2
Lerman, B.B.3
Mittal, S.4
-
13
-
-
21344434797
-
Oversensing in a newly implanted dual-chamber implantable cardioverter-defibrillator: What is the mechanism?
-
DOI 10.1016/j.hrthm.2005.03.007, PII S1547527105013354
-
B.P. Lee, M.A. Wood, and K.A. Ellenbogen Oversensing in a newly implanted dual-chamber implantable cardioverter-defibrillator: what is the mechanism? Heart Rhythm 2 2005 782 783 (Pubitemid 40903690)
-
(2005)
Heart Rhythm
, vol.2
, Issue.7
, pp. 782-783
-
-
Lee, B.P.1
Wood, M.A.2
Ellenbogen, K.A.3
-
14
-
-
79957997002
-
Weakened implantable cardioverter-defibrillator header bond: Abnormality not limited to subpectoral implants
-
J.J. Germano, A. Darge, and W.H. Maisel Weakened implantable cardioverter-defibrillator header bond: abnormality not limited to subpectoral implants Heart Rhythm 7 2010 701 704
-
(2010)
Heart Rhythm
, vol.7
, pp. 701-704
-
-
Germano, J.J.1
Darge, A.2
Maisel, W.H.3
-
15
-
-
0028069948
-
Troubleshooting implantable cardioverter defibrillator system malfunctions: The role of impedance measurements
-
L. Haddad, L.E. Padula, M. Moreau, and M.H. Schoenfeld Troubleshooting implantable cardioverter defibrillator system malfunctions: the role of impedance measurements Pacing Clin Electrophysiol 17 1994 1456 1461 (Pubitemid 24271496)
-
(1994)
PACE - Pacing and Clinical Electrophysiology
, vol.17
, Issue.9
, pp. 1456-1461
-
-
Haddad, L.1
Padula, L.E.2
Moreau, M.3
Schoenfeld, M.H.4
-
16
-
-
70349528282
-
The implantable cardioverter-defibrillator lead: Principles, progress, and promises
-
H.M. Haqqani, and H.G. Mond The implantable cardioverter-defibrillator lead: principles, progress, and promises Pacing Clin Electrophysiol 32 2009 1336 1353
-
(2009)
Pacing Clin Electrophysiol
, vol.32
, pp. 1336-1353
-
-
Haqqani, H.M.1
Mond, H.G.2
|