Volumn 10, Issue 8, 2008, Pages 914-917

Implantable cardiac defibrillator lead failure or myopotential oversensing? An approach to the diagnosis of noise on lead electrograms

Author keywords

Implantable cardioverter defibrillator; Oversensing of myopotentials

Indexed keywords

ADULT; AGED; ARTICLE; CASE REPORT; DEFIBRILLATOR; DEVICE; ELECTROGRAPHY; FOLLOW UP; HEART INFARCTION; HEART LEFT VENTRICLE FAILURE; HEART VENTRICLE TACHYCARDIA; HUMAN; MALE; MUSCLE POTENTIAL; NOISE; PECTORAL MUSCLE; PRIORITY JOURNAL; REOPERATION;

EID: 48749106819     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/eun167     Document Type: Article
Times cited : (26)

References (12)
  • 1
    • 0016281973 scopus 로고
    • Myopotential inhibition of demand pacemakers
    • Piller LW, Kennelly BM. Myopotential inhibition of demand pacemakers. Chest 1974;66:418-20.
    • (1974) Chest , vol.66 , pp. 418-420
    • Piller, L.W.1    Kennelly, B.M.2
  • 2
    • 0015938883 scopus 로고
    • Inhibition of demand pacemakers by skeletal muscle potentials
    • Winter DA. Inhibition of demand pacemakers by skeletal muscle potentials. JAMA 1973;223:527-9.
    • (1973) JAMA , vol.223 , pp. 527-529
    • Winter, D.A.1
  • 3
    • 0035212343 scopus 로고    scopus 로고
    • Inappropriate arrhythmia detection in implantable defibrillator therapy due to oversensing of diaphragmatic myopotentials
    • Schulte B, Sperzel J, Carlsson J, Dursch M, Erdogan A, Pitschner HF et al. Inappropriate arrhythmia detection in implantable defibrillator therapy due to oversensing of diaphragmatic myopotentials. J Interv Card Electrophysiol 2001;5:487-93.
    • (2001) J Interv Card Electrophysiol , vol.5 , pp. 487-493
    • Schulte, B.1    Sperzel, J.2    Carlsson, J.3    Dursch, M.4    Erdogan, A.5    Pitschner, H.F.6
  • 4
    • 0031868579 scopus 로고    scopus 로고
    • Myopotential sensing by a dual chamber implantable cardioverter defibrillator: Two case reports
    • Deshmukh P, Anderson K. Myopotential sensing by a dual chamber implantable cardioverter defibrillator: two case reports. J Cardiovasc Electrophysiol 1998;9:767-72.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 767-772
    • Deshmukh, P.1    Anderson, K.2
  • 5
    • 0036185885 scopus 로고    scopus 로고
    • Adjustment of maximum automatic sensitivity (automatic gain control) reduces inappropriate therapies in patients with implantable cardioverter defibrillators
    • Niehaus M, Neuzner J, Vogt J, Korte T, Tebbenjohanns J. Adjustment of maximum automatic sensitivity (automatic gain control) reduces inappropriate therapies in patients with implantable cardioverter defibrillators. Pacing Clin Electrophysiol 2002;25:151-5.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 151-155
    • Niehaus, M.1    Neuzner, J.2    Vogt, J.3    Korte, T.4    Tebbenjohanns, J.5
  • 6
    • 0033053953 scopus 로고    scopus 로고
    • Inappropriate shocks delivered by implantable cardiac defibrillators during oversensing of activity of diaphagmatic muscle
    • Babuty D, Fauchier L, Cosnay P. Inappropriate shocks delivered by implantable cardiac defibrillators during oversensing of activity of diaphagmatic muscle. Heart 1999;81:94-6.
    • (1999) Heart , vol.81 , pp. 94-96
    • Babuty, D.1    Fauchier, L.2    Cosnay, P.3
  • 7
    • 0035043891 scopus 로고    scopus 로고
    • Provoked and spontaneous high-frequency, low-amplitude, respirophasic noise transients in patients with implantable cardioverter defibrillators
    • Sweeney MO, Ellison KE, Shea JB, Newell JB. Provoked and spontaneous high-frequency, low-amplitude, respirophasic noise transients in patients with implantable cardioverter defibrillators. J Cardiovasc Electrophysiol 2001;12:402-10.
    • (2001) J Cardiovasc Electrophysiol , vol.12 , pp. 402-410
    • Sweeney, M.O.1    Ellison, K.E.2    Shea, J.B.3    Newell, J.B.4
  • 8
    • 40049087455 scopus 로고    scopus 로고
    • Ventricular oversensing in 518 patients with implanted cardiac defibrillators: Incidence, complications, and solutions
    • Rauwolf T, Guenther M, Hass N, Schnabel A, Bock M, Braun MU et al. Ventricular oversensing in 518 patients with implanted cardiac defibrillators: incidence, complications, and solutions. Europace 2007;9:1041-7.
    • (2007) Europace , vol.9 , pp. 1041-1047
    • Rauwolf, T.1    Guenther, M.2    Hass, N.3    Schnabel, A.4    Bock, M.5    Braun, M.U.6
  • 9
    • 0036257741 scopus 로고    scopus 로고
    • Discrimination of ventricular tachycardia from supraventricular tachycardia by a downloaded wavelet-transform morphology algorithm: A paradigm for development of implantable cardioverter defibrillator detection algorithms
    • Swerdlow CD, Brown ML, Lurie K, Zhang J, Wood NM, Olson WH et al. Discrimination of ventricular tachycardia from supraventricular tachycardia by a downloaded wavelet-transform morphology algorithm: a paradigm for development of implantable cardioverter defibrillator detection algorithms. J Cardiovasc Electrophysiol 2002;13:432-41.
    • (2002) J Cardiovasc Electrophysiol , vol.13 , pp. 432-441
    • Swerdlow, C.D.1    Brown, M.L.2    Lurie, K.3    Zhang, J.4    Wood, N.M.5    Olson, W.H.6
  • 11
    • 44749089369 scopus 로고    scopus 로고
    • Inadvertent transposition of defibrillator coil terminal pins causing inappropriate ICD therapies
    • Issa ZF. Inadvertent transposition of defibrillator coil terminal pins causing inappropriate ICD therapies. J Interv Card Electrophysiol 2008;22:71-40.
    • (2008) J Interv Card Electrophysiol , vol.22 , pp. 71-40
    • Issa, Z.F.1
  • 12
    • 33750713087 scopus 로고    scopus 로고
    • Myopotentials leading to ventricular fibrillation detection after advisory defibrillator generator replacement
    • Eckart RE, Hruczkowski TW, Stevenson WG, Epstein LM. Myopotentials leading to ventricular fibrillation detection after advisory defibrillator generator replacement. Pacing Clin Electrophysiol 2006;29:1273-6.
    • (2006) Pacing Clin Electrophysiol , vol.29 , pp. 1273-1276
    • Eckart, R.E.1    Hruczkowski, T.W.2    Stevenson, W.G.3    Epstein, L.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.