메뉴 건너뛰기




Volumn 10, Issue 1, 2011, Pages 61-78

Ventilation strategies in school buildings for optimization of air quality, energy consumption and environmental comfort in mediterranean climates

Author keywords

Air changes; Carbon dioxide; Energy consumption; Environmental comfort; Indoor air quality; Occupied classrooms; Particulate matter; Questionnaires; Retrofitting; monitoring; Schools; Ventilation

Indexed keywords

AIR QUALITY; CARBON DIOXIDE; ENERGY UTILIZATION; INDOOR AIR POLLUTION; NEONATAL MONITORING; SURVEYS;

EID: 79957948176     PISSN: 14733315     EISSN: None     Source Type: Journal    
DOI: 10.1080/14733315.2011.11683935     Document Type: Article
Times cited : (13)

References (15)
  • 2
    • 25644435690 scopus 로고    scopus 로고
    • 1 in a classroom
    • DOI 10.1016/j.envres.2004.12.001, PII S0013935104002373
    • Braniš. M, Řezáčová P and Domasova M: (2005). "The effect of outdoor air and indoor human activity on mass concentrations of PM10, PM2.5, and PM1 in a classroom", Environmental Research, 99, pp143-149. (Pubitemid 41382440)
    • (2005) Environmental Research , vol.99 , Issue.2 , pp. 143-149
    • Branis, M.1    Rezacova, P.2    Domasova, M.3
  • 3
    • 35449007326 scopus 로고    scopus 로고
    • Ventilation rates in schools
    • DOI 10.1016/j.buildenv.2006.03.018, PII S0360132306003568, Indoor Air 2005: Modeling, Assessment, and Control of Indoor Air Quality
    • Clements-Croome DJ, Awbi HB, Bakó-Biró ZS, Kochhar N and Williams M: (2008). "Ventilation rates in schools", Building and Environment, 43, pp362-367. (Pubitemid 47628365)
    • (2008) Building and Environment , vol.43 , Issue.3 , pp. 362-367
    • Clements-Croome, D.J.1    Awbi, H.B.2    Bako-Biro, Z.3    Kochhar, N.4    Williams, M.5
  • 4
    • 0037365997 scopus 로고    scopus 로고
    • Indoor air quality, ventilation and health symptoms in schools: An analysis of existing information
    • DOI 10.1034/j.1600-0668.2003.00153.x
    • Daisey JM, Angell WJ and Apte MG: (2003). "Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information", Indoor Air, 13, pp53-64. (Pubitemid 37463589)
    • (2003) Indoor Air , vol.13 , Issue.1 , pp. 53-64
    • Daisey, J.M.1    Angell, W.J.2    Apte, M.G.3
  • 6
    • 1542741010 scopus 로고    scopus 로고
    • The Stockholm indoor environment questionnaire: A sociologically based tool for the assessment of indoor environment and health in dwellings
    • DOI 10.1111/j.1600-0668.2004.00204.x
    • Engvall K, Norrby C and Sandstedt E: (2004). "The Stockholm Indoor Environment Questionnaire: a sociologically based tool for the assessment of indoor environment and health in dwellings", Indoor Air, 14, pp24-33. (Pubitemid 38623948)
    • (2004) Indoor Air , vol.14 , Issue.1 , pp. 24-33
    • Engvall, K.1    Norrby, C.2    Sandstedt, E.3
  • 8
    • 34547950363 scopus 로고    scopus 로고
    • Indoor air quality and occupant satisfaction in five mechanically and four naturally ventilated open-plan office buildings
    • DOI 10.1016/j.buildenv.2006.07.042, PII S0360132306003775
    • Hummelgaard J, Juhl P, Sabjornsson K, Clausen G, Toftum J and Langkilde G: (2007). "Indoor air quality and occupant satisfaction in five mechanically and four naturally ventilated openplan office buildings", Building and Environment, 42, pp4051-4058. (Pubitemid 47264046)
    • (2007) Building and Environment , vol.42 , Issue.12 , pp. 4051-4058
    • Hummelgaard, J.1    Juhl, P.2    Saebjornsson, K.O.3    Clausen, G.4    Toftum, J.5    Langkilde, G.6
  • 9
    • 71549124241 scopus 로고    scopus 로고
    • Energy performance of buildings - Calculation of energy use for space heating and cooling
    • ISO 13790
    • ISO 13790:2008 "Energy performance of buildings - Calculation of energy use for space heating and cooling" International Standards Organisation.
    • (2008) International Standards Organisation
  • 10
    • 47549109830 scopus 로고    scopus 로고
    • Experimental investigation of the air flow and indoor carbon dioxide concentration in classrooms with intermittent natural ventilation
    • Santamouris M, Pavlou K, Synnefa A, Niachou K and Kolokotsa D: (2008). "Experimental investigation of the air flow and indoor carbon dioxide concentration in classrooms with intermittent natural ventilation", Energy and Buildings, 40, pp1833-1843.
    • (2008) Energy and Buildings , vol.40 , pp. 1833-1843
    • Santamouris, M.1    Pavlou, K.2    Synnefa, A.3    Niachou, K.4    Kolokotsa, D.5
  • 11
    • 51449095727 scopus 로고    scopus 로고
    • Performance test for evaluating the reduction of VOCs in rooms and evaluating the lifetime of sorptive building materials
    • Seo J and Kato S: (2009). "Performance test for evaluating the reduction of VOCs in rooms and evaluating the lifetime of sorptive building materials", Building and Environment, 44, pp207-215.
    • (2009) Building and Environment , vol.44 , pp. 207-215
    • Seo, J.1    Kato, S.2
  • 15
    • 34548459795 scopus 로고    scopus 로고
    • A multivariate-logistic model for acceptance of indoor environmental quality (IEQ) in offices
    • DOI 10.1016/j.buildenv.2007.01.001, PII S0360132307000029
    • Wong LT, Mui KW and Hui PS: (2008). "A multivariate-logistic model for acceptance of indoor environmental quality (IEQ) in offices", Building and Environment, 43, pp1-6. (Pubitemid 47355261)
    • (2007) Building and Environment , vol.43 , Issue.1 , pp. 1-6
    • Wong, L.T.1    Mui, K.W.2    Hui, P.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.