메뉴 건너뛰기




Volumn , Issue STANDARD 62.1, 2010, Pages 1-70

Ventilation for acceptable indoor air quality
[No Author Info available]

Author keywords

[No Author keywords available]

Indexed keywords


EID: 84856666398     PISSN: 10412336     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (18)

References (22)
  • 1
    • 84856636155 scopus 로고    scopus 로고
    • Code of Federal Regulations, Title 40 Part 50 (40 CFR 50), as amended July 30, 2004 and Oct. 17, U.S. Environmental Protection Agency, accessed June 20, 2008
    • National Primary and Secondary Ambient Air Quality Standards, Code of Federal Regulations, Title 40 Part 50 (40 CFR 50), as amended July 30, 2004 and Oct. 17, 2006. U.S. Environmental Protection Agency. www.epa.gov/air/criteria. html, accessed June 20, 2008.
    • (2006) National Primary and Secondary Ambient Air Quality Standards
  • 2
    • 0003878071 scopus 로고
    • Sheet Metal and Air Conditioning Contractors' Association, Inc. (SMACNA), Chantilly, VA
    • HVAC Air Duct Leakage Test Manual, First Edition, 1985. Sheet Metal and Air Conditioning Contractors' Association, Inc. (SMACNA), Chantilly, VA.
    • (1985) HVAC Air Duct Leakage Test Manual, First Edition
  • 7
    • 84856686414 scopus 로고    scopus 로고
    • American Conference of Governmental Industrial Hygienists (ACGIH), Committee on Industrial Ventilation, Lansing, MI
    • Industrial Ventilation: A Manual of Recommended Practice, 26th Edition, 2007. American Conference of Governmental Industrial Hygienists (ACGIH), Committee on Industrial Ventilation, Lansing, MI.
    • (2007) Industrial Ventilation: A Manual of Recommended Practice 26th Edition
  • 17
    • 84856659865 scopus 로고    scopus 로고
    • American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA
    • ANSI/ASHRAE 129-1997 (RA 02), Measuring Air Change Effectiveness. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA.
    • ANSI/ASHRAE 129-1997 (RA 02), Measuring Air Change Effectiveness
  • 19
    • 84856642035 scopus 로고    scopus 로고
    • Sheet Metal and Air Conditioning Contractors' National Association, Inc. (SMACNA), Chantilly, VA
    • Fibrous Glass Duct Construction Standards, 7th Edition, 2003. Sheet Metal and Air Conditioning Contractors' National Association, Inc. (SMACNA), Chantilly, VA.
    • (2003) Fibrous Glass Duct Construction Standards, 7th Edition
  • 22
    • 84856653442 scopus 로고    scopus 로고
    • Sheet Metal and Air Conditioning Contractors' National Association, Inc. (SMACNA), Chantilly, VA
    • HVAC Systems - Testing, Adjusting and Balancing, 3rd Edition, 2002. Sheet Metal and Air Conditioning Contractors' National Association, Inc. (SMACNA), Chantilly, VA.
    • (2002) HVAC Systems - Testing, Adjusting and Balancing, 3rd Edition


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.