메뉴 건너뛰기




Volumn 155, Issue 2, 2011, Pages 538-544

Polymer-grafted QCM chemical sensor and application to heavy metal ions real time detection

Author keywords

Heavy metal ions detection; Multifunctional polymers; Polymer grafted quartz crystal microbalance

Indexed keywords

AQUEOUS SOLUTIONS; AT-CUT QUARTZ RESONATORS; COMPLEXING ABILITY; ENVIRONMENTAL MONITORING; FLOW TYPE; GOLD ELECTRODES; GOLD SURFACES; MULTIFUNCTIONAL POLYMER; MULTIFUNCTIONAL POLYMERS; NATURAL WATERS; POLYMER-GRAFTED; QCM SENSORS; REAL-TIME DETECTION; SURFACE-MODIFIED; TOTAL REFLECTION X-RAY FLUORESCENCE; X RAY REFLECTIVITY;

EID: 79957805871     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2011.01.003     Document Type: Article
Times cited : (62)

References (21)
  • 1
    • 0030148374 scopus 로고    scopus 로고
    • Determination of copper, cadmium and lead in biological samples by isotope dilution inductively coupled plasma mass spectrometry after on-line pre-treatment by anodic stripping voltammetry
    • T.J. Hwang, and S.-J. Jiang Determination of copper, cadmium and lead in biological samples by isotope dilution inductively coupled plasma mass spectrometry after online pre-treatment by anodic stripping voltammetry J. Anal. Atom. Spectrosc. 11 1996 353 357 (Pubitemid 126576680)
    • (1996) Journal of Analytical Atomic Spectrometry , vol.11 , Issue.5 , pp. 353-357
    • Hwang, T.-J.1    Jiang, S.-J.2
  • 2
    • 30144446240 scopus 로고    scopus 로고
    • A review on solid phase microextraction - High performance liquid chromatography as a novel tool for the analysis of toxic metal ions
    • DOI 10.1016/j.talanta.2005.06.005, PII S0039914005003346
    • A.K. Malik, V. Kaur, and N. Verma A review on solid phase microextraction - high performance liquid chromatography as a novel tool for the analysis of toxic metal ions Talanta 68 3 2006 842 849 (Pubitemid 43052496)
    • (2006) Talanta , vol.68 , Issue.3 , pp. 842-849
    • Malik, A.K.1    Kaur, V.2    Verma, N.3
  • 3
    • 33746347055 scopus 로고    scopus 로고
    • A comparison of boron-doped diamond thin-film and Hg-coated glassy carbon electrodes for anodic stripping voltammetric determination of heavy metal ions in aqueous media
    • DOI 10.1016/j.aca.2006.05.094, PII S0003267006011809
    • E.A. Mcgaw, and G.M. Swain A comparison of boron-doped diamond thin film and Hg-coated glassy carbon electrodes for anodic stripping voltammetric determination of heavy metal ions in aqueous media Anal. Chim. Acta 575 2 2006 180 189 (Pubitemid 44118190)
    • (2006) Analytica Chimica Acta , vol.575 , Issue.2 , pp. 180-189
    • McGaw, E.A.1    Swain, G.M.2
  • 4
    • 84951279351 scopus 로고
    • Verwendung von Schwingsquarzen zur Wägung dunner Schichten und zur Mikrowägung
    • G. Sauerbrey Verwendung von Schwingsquarzen zur Wägung dunner Schichten und zur Mikrowägung Z. Phys. 155 1959 206 212
    • (1959) Z. Phys. , vol.155 , pp. 206-212
    • Sauerbrey, G.1
  • 5
    • 0037015697 scopus 로고    scopus 로고
    • Quartz crystal microbalance determination of organophosphorus and carbamate pesticides
    • DOI 10.1016/S0003-2670(02)00668-2, PII S0003267002006682
    • N.G. Karousos, S. Aouabdi, A.S. Way, and S.M. Reddy Quartz crystal microbalance determination of organophosphorus and carbamate pesticides Anal. Chim. Acta 469 2002 189 196 (Pubitemid 35284237)
    • (2002) Analytica Chimica Acta , vol.469 , Issue.2 , pp. 189-196
    • Karousos, N.G.1    Aouabdi, S.2    Way, A.S.3    Reddy, S.M.4
  • 6
    • 8844286076 scopus 로고    scopus 로고
    • Piezoelectric sensor functionalised by a self-assembled bipyridinium derivative: Characterisation and preliminary applications in the detection of heavy metal ions
    • DOI 10.1016/j.bios.2004.04.028, PII S0956566304002878, Synthetic Receptors
    • S. Casilli, C. Malitesta, S. Conoci, S. Petralia, S. Sortino, and L. Valli Piezoelectric sensor functionalised by a self-assembled bipyridinium derivative: characterisation and preliminary applications in the detection of heavy metal ions Biosens. Bioelectron. 20 2004 1190 1195 (Pubitemid 39535577)
    • (2004) Biosensors and Bioelectronics , vol.20 , Issue.6 , pp. 1190-1195
    • Casilli, S.1    Malitesta, C.2    Conoci, S.3    Petralia, S.4    Sortino, S.5    Valli, L.6
  • 7
    • 16644386482 scopus 로고    scopus 로고
    • Development of a piezoelectric immunosensor for the detection of alpha-fetoprotein
    • W.C. Tsai, and I.C. Lin Development of a piezoelectric immunosensor for the detection of alpha-fetoprotein Sens. Actuators B 106 2005 455 460
    • (2005) Sens. Actuators B , vol.106 , pp. 455-460
    • Tsai, W.C.1    Lin, I.C.2
  • 8
    • 0035894329 scopus 로고    scopus 로고
    • Comparison of different protein immobilization methods on quartz crystal microbalance surface in flow injection immunoassay
    • DOI 10.1006/abio.2001.5409
    • Y.-C. Liu, C.-M. Wang, and K.-P. Hsiung Comparison of different protein immobilization methods on quartz crystal microbalance surface in flow injection immunoassay Anal. Biochem. 299 2001 130 135 (Pubitemid 34053401)
    • (2001) Analytical Biochemistry , vol.299 , Issue.2 , pp. 130-135
    • Liu, Y.-C.1    Wang, C.-M.2    Hsiung, K.-P.3
  • 9
    • 0003004901 scopus 로고    scopus 로고
    • Quartz crystal microbalance for bioanalytical application
    • A. Janshoff, and C. Steinem Quartz crystal microbalance for bioanalytical application Sensor Update 9 2001 313 354
    • (2001) Sensor Update , vol.9 , pp. 313-354
    • Janshoff, A.1    Steinem, C.2
  • 10
    • 0034672649 scopus 로고    scopus 로고
    • Polymer chemical structure is a key determinant of physicochemical and colloidal properties of polymer-DNA complexes for gene delivery
    • N.A. Jones, I.R.C. Hill, S. Stolnik, S.S. Davis, and M.C. Garnett Polymer chemical structure is a key determinant of physicochemical and colloidal properties of polymer-DNA complexes for gene delivery Biochim. Biophys. Acta: Gene Struct. Expr. 1517 1 2000 1 18
    • (2000) Biochim. Biophys. Acta: Gene Struct. Expr. , vol.1517 , Issue.1 , pp. 1-18
    • Jones, N.A.1    Hill, I.R.C.2    Stolnik, S.3    Davis, S.S.4    Garnett, M.C.5
  • 11
    • 0028607444 scopus 로고
    • Recent results on functional polymers and macromonomers of interest as biomaterials or for biomaterial modification
    • P. Ferruti, E. Ranucci, L. Sartore, F. Bignotti, M.A. Marchisio, P. Bianciardi, and F.M. Veronese Recent results on functional polymers and macromonomers of interest as biomaterials or for biomaterial modification Biomaterials 15 15 1994 1235 1241
    • (1994) Biomaterials , vol.15 , Issue.15 , pp. 1235-1241
    • Ferruti, P.1    Ranucci, E.2    Sartore, L.3    Bignotti, F.4    Marchisio, M.A.5    Bianciardi, P.6    Veronese, F.M.7
  • 12
    • 0037043611 scopus 로고    scopus 로고
    • Grafting of selected presynthesized macromonomers onto various dispersions of silica particles
    • L. Sartore, M. Penco, F. Bignotti, I. Peroni, M.H. Gil, A. Ramos, and A. D'Amore Grafting of selected presynthesized macromonomers onto various dispersions of silica particles J. Appl. Polym. Sci. 85 6 2002 1287 1296
    • (2002) J. Appl. Polym. Sci. , vol.85 , Issue.6 , pp. 1287-1296
    • Sartore, L.1    Penco, M.2    Bignotti, F.3    Peroni, I.4    Gil, M.H.5    Ramos, A.6    D'Amore, A.7
  • 13
    • 25144456062 scopus 로고    scopus 로고
    • New carbon black composite vapor detectors based on multifunctional polymers
    • L. Sartore, M. Penco, S. Della Sciucca, G. Borsarini, and V. Ferrari New carbon black composite vapor detectors based on multifunctional polymers Sens. Actuators B 111-112 2005 160 165
    • (2005) Sens. Actuators B , vol.111-112 , pp. 160-165
    • Sartore, L.1    Penco, M.2    Della Sciucca, S.3    Borsarini, G.4    Ferrari, V.5
  • 14
    • 0001634592 scopus 로고    scopus 로고
    • IMD-software for modelling the optical properties of multilayer films
    • D.L. Windt IMD-software for modelling the optical properties of multilayer films Comput. Phys. 12 1998 360 370
    • (1998) Comput. Phys. , vol.12 , pp. 360-370
    • Windt, D.L.1
  • 15
    • 0030574149 scopus 로고    scopus 로고
    • Modified monolayer electrodes for electrochemical and piezoelectric analysis of substrate-receptor interactions: Novel immunosensor electrodes
    • DOI 10.1016/S0022-0728(96)04760-2, PII S0022072896047602
    • Y. Cohen, S. Levi, S. Rubin, and I. Willner Modified monolayer electrodes for electrochemical and piezoelectric analysis of substrate-receptor interactions: novel immunosensor electrodes J. Electroanal. Chem. 417 1996 65 75 (Pubitemid 126385563)
    • (1996) Journal of Electroanalytical Chemistry , vol.417 , Issue.1-2 , pp. 65-75
    • Cohen, Y.1    Levi, S.2    Rubin, S.3    Willner, I.4
  • 17
    • 33645164074 scopus 로고    scopus 로고
    • X-ray reflectivity for the characterization of thin films
    • E. Bontempi X-ray reflectivity for the characterization of thin films Recent Res. Dev. Chem. Phys. 5 2004 461 488
    • (2004) Recent Res. Dev. Chem. Phys. , vol.5 , pp. 461-488
    • Bontempi, E.1
  • 19
  • 20
    • 77950918132 scopus 로고    scopus 로고
    • Use of total reflection X-ray fluorescence (TXRF) for the evaluation of heavy metal poisoning due to the improper use of a traditional ayurvedic drug
    • L. Borgese, A. Zacco, E. Bontempi, M. Pellegatta, L. Vigna, L. Patrini, L. Riboldi, F.M. Rubino, and L.E. Depero Use of total reflection X-ray fluorescence (TXRF) for the evaluation of heavy metal poisoning due to the improper use of a traditional ayurvedic drug J. Pharm. Biomed. Anal. 52 5 2010 787 790
    • (2010) J. Pharm. Biomed. Anal. , vol.52 , Issue.5 , pp. 787-790
    • Borgese, L.1    Zacco, A.2    Bontempi, E.3    Pellegatta, M.4    Vigna, L.5    Patrini, L.6    Riboldi, L.7    Rubino, F.M.8    Depero, L.E.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.