메뉴 건너뛰기




Volumn 46, Issue 6, 2011, Pages 1392-1405

A micropower low-noise neural recording front-end circuit for epileptic seizure detection

Author keywords

bandpass filter; Deep brain stimulation; elliptic filter; epilepsy; fast ripples; low power low noise design; neural amplifier; noise efficiency factor; subthreshold circuit design

Indexed keywords

DEEP BRAIN STIMULATION; ELLIPTIC FILTERS; EPILEPSY; FAST RIPPLES; LOW POWER; NEURAL AMPLIFIER; NOISE EFFICIENCY FACTOR; SUBTHRESHOLD CIRCUIT DESIGN;

EID: 79957639728     PISSN: 00189200     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSSC.2011.2126370     Document Type: Article
Times cited : (135)

References (36)
  • 1
    • 0037562843 scopus 로고    scopus 로고
    • Epileptic seizure prediction and control
    • May
    • L. D. Iasemidis, "Epileptic seizure prediction and control," IEEE Trans. Biomed. Eng., vol. 50, pp. 549-558, May 2003.
    • (2003) IEEE Trans. Biomed. Eng. , vol.50 , pp. 549-558
    • Iasemidis, L.D.1
  • 2
    • 0036829482 scopus 로고    scopus 로고
    • Long-term amygdalohippocampal stimulation for refractory temporal lobe epilepsy
    • DOI 10.1002/ana.10323
    • K. Vonck, P. Boon, E. Achten, J. De Reuck, and J. Caemaert, "Longterm amygdalohippocampal stimulation for refractory temporal lobe epilepsy," Ann. Neurol., vol. 52, pp. 556-565, Nov. 2002. (Pubitemid 35246858)
    • (2002) Annals of Neurology , vol.52 , Issue.5 , pp. 556-565
    • Vonck, K.1    Boon, P.2    Achten, E.3    De Reuck, J.4    Caemaert, J.5
  • 3
    • 0036280279 scopus 로고    scopus 로고
    • Chronic anterior thalamus stimulation for intractable epilepsy
    • DOI 10.1046/j.1528-1157.2002.26001.x
    • M. Hodaie, R. A. Wennberg, J. O. Dostrovsky, and A. M. Lozano, "Chronic anterior thalamus stimulation for intractable epilepsy," Epilepsia, vol. 43, pp. 603-608, Jun. 2002. (Pubitemid 34627719)
    • (2002) Epilepsia , vol.43 , Issue.6 , pp. 603-608
    • Hodaie, M.1    Wennberg, R.A.2    Dostrovsky, J.O.3    Lozano, A.M.4
  • 4
    • 3142557935 scopus 로고    scopus 로고
    • High-frequency oscillations and seizure generation in neocortical epilepsy
    • DOI 10.1093/brain/awh149
    • G.A. Worrell, L. Parish, S.D. Cranstoun, R. Jonas,G. Baltuch, and B. Litt, "High-frequency oscillations and seizure generation in neocortical epilepsy," Brain, vol. 127, pp. 1496-1506, Jul. 2004. (Pubitemid 38899403)
    • (2004) Brain , vol.127 , Issue.7 , pp. 1496-1506
    • Worrell, G.A.1    Parish, L.2    Cranstoun, S.D.3    Jonas, R.4    Baltuch, G.5    Litt, B.6
  • 5
    • 35248854440 scopus 로고    scopus 로고
    • High-frequency oscillations detected in epileptic networks using swarmed neural-network features
    • DOI 10.1007/s10439-007-9333-7
    • H. Firpi, O. Smart, G.Worrell, E. Marsh, D. Dlugos, and B. Litt, "Highfrequency oscillations detected in epileptic networks using swarmed neural-network features," Ann. Biomed. Eng., vol. 35, pp. 1573-1584, Sep. 2007. (Pubitemid 350092433)
    • (2007) Annals of Biomedical Engineering , vol.35 , Issue.9 , pp. 1573-1584
    • Firpi, H.1    Smart, O.2    Worrell, G.3    Marsh, E.4    Dlugos, D.5    Litt, B.6
  • 7
    • 51949094179 scopus 로고    scopus 로고
    • A 64 channel programmable closed-loop deep brain stimulator with 8 channel neural amplifier and logarithmic ADC
    • J. Lee, H. Rhew, D.Kipke, and M. Flynn, "A 64 channel programmable closed-loop deep brain stimulator with 8 channel neural amplifier and logarithmic ADC," in Symp. VLSI Circuits Dig., 2008, pp. 76-77.
    • (2008) Symp. VLSI Circuits Dig. , pp. 76-77
    • Lee, J.1    Rhew, H.2    Kipke, D.3    Flynn, M.4
  • 8
    • 0036799512 scopus 로고    scopus 로고
    • Quantitative analysis of high-frequency oscillations (80-500 Hz) recorded in human epileptic hippocampus and entorhinal cortex
    • R. J. Staba, C. L. Wilson, A. Bragin, I. Fried, and J. Engel, Jr., "Quantitative analysis of high-frequency oscillations (80-500 Hz) recorded in human epileptic hippocampus and entorhinal cortex," J. Neurophysiol., vol. 88, pp. 1743-1752, Oct. 2002. (Pubitemid 35191178)
    • (2002) Journal of Neurophysiology , vol.88 , Issue.4 , pp. 1743-1752
    • Staba, R.J.1    Wilson, C.L.2    Bragin, A.3    Fried, I.4
  • 9
    • 0036523033 scopus 로고    scopus 로고
    • Local generation of fast ripples in epileptic brain
    • A. Bragin, I. Mody, C. L. Wilson, and J. Engel, Jr., "Local generation of fast ripples in epileptic brain," J. Neurosci., vol. 22, pp. 2012-2021, Mar. 2002. (Pubitemid 35386321)
    • (2002) Journal of Neuroscience , vol.22 , Issue.5 , pp. 2012-2021
    • Bragin, A.1    Mody, I.2    Wilson, C.L.3    Engel Jr., J.4
  • 10
    • 34548261378 scopus 로고    scopus 로고
    • Interictal high-frequency oscillations (10-500 Hz) in the intracerebral EEG of epileptic patients
    • DOI 10.1093/brain/awm149
    • E. Urrestarazu, R. Chander, F. Dubeau, and J. Gotman, "Interictal high-frequency oscillations (100-500 Hz) in the intracerebral EEG of epileptic patients," Brain, vol. 130, pp. 2354-2366, Sep. 2007. (Pubitemid 47327627)
    • (2007) Brain , vol.130 , Issue.9 , pp. 2354-2366
    • Urrestarazu, E.1    Chander, R.2    Dubeau, F.3    Gotman, J.4
  • 11
    • 33745115643 scopus 로고    scopus 로고
    • High-frequency oscillations during human focal seizures
    • DOI 10.1093/brain/awl085
    • J. D. Jirsch, E. Urrestarazu, P. LeVan, A. Olivier, F. Dubeau, and J. Gotman, "High-frequency oscillations during human focal seizures," Brain, vol. 129, pp. 1593-1608, Jun. 2006. (Pubitemid 43999390)
    • (2006) Brain , vol.129 , Issue.6 , pp. 1593-1608
    • Jirsch, J.D.1    Urrestarazu, E.2    LeVan, P.3    Olivier, A.4    Dubeau, F.5    Gotman, J.6
  • 12
    • 41849092966 scopus 로고    scopus 로고
    • High-frequency oscillations in human temporal lobe: Simultaneous microwire and clinical macroelectrode recordings
    • DOI 10.1093/brain/awn006
    • G. A.Worrell, A. B. Gardner, S. M. Stead, S. Hu, S. Goerss, G. J. Cascino, F. B. Meyer, R. Marsh, and B. Litt, "High-frequency oscillations in human temporal lobe: Simultaneous microwire and clinical macroelectrode recordings," Brain, vol. 131, pp. 928-937, Apr. 2008. (Pubitemid 351499420)
    • (2008) Brain , vol.131 , Issue.4 , pp. 928-937
    • Worrell, G.A.1    Gardner, A.B.2    Stead, S.M.3    Hu, S.4    Goerss, S.5    Cascino, G.J.6    Meyer, F.B.7    Marsh, R.8    Litt, B.9
  • 14
    • 0032888084 scopus 로고    scopus 로고
    • A 100-channel system for real time detection and storage of extracellular spike waveforms
    • DOI 10.1016/S0165-0270(99)00076-X, PII S016502709900076X
    • K. S. Guillory and R. A.Normann, "A 100-channel systemfor real time detection and storage of extracellular spike waveforms," J. Neurosci. Methods, vol. 91, pp. 21-29, Sep. 1999. (Pubitemid 29459086)
    • (1999) Journal of Neuroscience Methods , vol.91 , Issue.1-2 , pp. 21-29
    • Guillory, K.S.1    Normann, R.A.2
  • 15
    • 0038718680 scopus 로고    scopus 로고
    • A low-power low-noise CMOS amplifier for neural recording applications
    • Jun.
    • R. Harrison and C. Charles, "A low-power low-noise CMOS amplifier for neural recording applications," IEEE J. Solid-State Circuits, vol. 38, no. 6, pp. 958-965, Jun. 2003.
    • (2003) IEEE J. Solid-State Circuits , vol.38 , Issue.6 , pp. 958-965
    • Harrison, R.1    Charles, C.2
  • 17
    • 0028572709 scopus 로고
    • Analog VLSI adaptive, logarithmic wide- dynamic-range photoreceptor
    • T. Delbrück and C. A. Mead, "Analog VLSI adaptive, logarithmic wide- dynamic-range photoreceptor," in Proc. IEEE Int. Symp. Circuits and Systems, 1994, vol. 4, pp. 339-342.
    • (1994) Proc. IEEE Int. Symp. Circuits and Systems , vol.4 , pp. 339-342
    • Delbrück, T.1    Mead, C.A.2
  • 18
    • 33846357767 scopus 로고    scopus 로고
    • An integrated system for multichannel neuronal recording with spike/LFP separation, integrated A/D conversion and threshold detection
    • DOI 10.1109/TBME.2006.883732, 18
    • Y. Perelman and R. Ginosar, "An integrated system for multichannel neuronal recording with spike/LFP separation, integrated A/D conversion and threshold detection," IEEE Trans. Biomed. Eng., vol. 54, pp. 130-137, Jan. 2007. (Pubitemid 46127146)
    • (2007) IEEE Transactions on Biomedical Engineering , vol.54 , Issue.1 , pp. 130-137
    • Perelman, Y.1    Ginosar, R.2
  • 19
    • 63449088602 scopus 로고    scopus 로고
    • A 1-V 450-nW fully integrated programmable biomedical sensor interface chip
    • Apr.
    • X. Zou, X. Xu, L. Yao, and Y. Lian, "A 1-V 450-nW fully integrated programmable biomedical sensor interface chip," IEEE J. Solid-State Circuits, vol. 44, no. 4, pp. 1067-1077, Apr. 2009.
    • (2009) IEEE J. Solid-State Circuits , vol.44 , Issue.4 , pp. 1067-1077
    • Zou, X.1    Xu, X.2    Yao, L.3    Lian, Y.4
  • 20
    • 34548823775 scopus 로고    scopus 로고
    • A low-noise preamplifier with adjustable gain and bandwidth for biopotential recording applications
    • 4252636, 2007 IEEE International Symposium on Circuits and Systems, ISCAS 2007
    • M. Yin and M. Ghovanloo, "A low-noise preamplifier with adjustable gain and bandwidth for biopotential recording applications," in Proc. IEEE Int. Symp. Circuits and Systems, 2007, pp. 321-324. (Pubitemid 47448506)
    • (2007) Proceedings - IEEE International Symposium on Circuits and Systems , pp. 321-324
    • Yin, M.1    Ghovanloo, M.2
  • 21
    • 0022031047 scopus 로고
    • Active filter design using operational transconductance amplifiers: A tutorial
    • R. L. Geiger and E. Sánchez-Sinencio, "Active filter design using operational transconductance amplifiers: A tutorial," IEEE Circuits and Devices Mag., vol. 1, pp. 20-32, Mar. 1985. (Pubitemid 15597568)
    • (1985) IEEE Circuits and Devices Magazine , vol.1 , Issue.2 , pp. 20-32
    • Geiger Randall, L.1    Sanchez-Sinencio, E.2
  • 22
    • 0029342165 scopus 로고
    • An analytical MOS transistor model valid in all regions of operation and dedicated to lowvoltage and low-current applications
    • Jul.
    • C. C. Enz, F. Krummenacher, and E. A. Vittoz, "An analytical MOS transistor model valid in all regions of operation and dedicated to lowvoltage and low-current applications," Analog Integr. Circuits Signal Process., vol. 8, pp. 83-114, Jul. 1995.
    • (1995) Analog Integr. Circuits Signal Process. , vol.8 , pp. 83-114
    • Enz, C.C.1    Krummenacher, F.2    Vittoz, E.A.3
  • 24
    • 51949105156 scopus 로고    scopus 로고
    • A 2 μW 100 nV/rtHz chopper-stabilized instrumentation amplifier for chronic measurement of neural field potentials
    • Dec.
    • T. Denison, K. Consoer, W. Santa, A. Avestruz, J. Cooley, and A. Kelly, "A 2 μW 100 nV/rtHz chopper-stabilized instrumentation amplifier for chronic measurement of neural field potentials," IEEE J. Solid-State Circuits, vol. 42, no. 12, pp. 2934-2945, Dec. 2007.
    • (2007) IEEE J. Solid-State Circuits , vol.42 , Issue.12 , pp. 2934-2945
    • Denison, T.1    Consoer, K.2    Santa, W.3    Avestruz, A.4    Cooley, J.5    Kelly, A.6
  • 26
    • 39549086320 scopus 로고    scopus 로고
    • A low-power integrated bioamplifier with active low-frequency suppression
    • DOI 10.1109/TBCAS.2007.914490
    • B. Gosselin, M. Sawan, and C. A. Chapman, "A low-power integrated bioamplifier with active low-frequency suppression," IEEE Trans. Biomed. Circuits Syst., vol. 1, pp. 184-192, Sep. 2007. (Pubitemid 351279737)
    • (2007) IEEE Transactions on Biomedical Circuits and Systems , vol.1 , Issue.3 , pp. 184-192
    • Gosselin, B.1    Sawan, M.2    Chapman, C.A.3
  • 27
    • 1942542472 scopus 로고    scopus 로고
    • A fully integrated neural recording amplifier with DC input stabilization
    • DOI 10.1109/TBME.2004.824126
    • P. Mosheni and K. Najafi, "A fully integrated neural recording amplifier with DC input stabilization," IEEE Trans. Biomed. Eng., vol. 51, pp. 832-837, May 2004. (Pubitemid 38525717)
    • (2004) IEEE Transactions on Biomedical Engineering , vol.51 , Issue.5 , pp. 832-837
    • Mohseni, P.1    Najafi, K.2
  • 29
    • 36048992157 scopus 로고    scopus 로고
    • Enhancing general performance of folded cascode amplifier by recycling current
    • Nov.
    • R. Assaad and J. Silva-Martinez, "Enhancing general performance of folded cascode amplifier by recycling current," Electron. Lett., vol. 43, no. 23, Nov. 2007.
    • (2007) Electron. Lett. , vol.43 , Issue.23
    • Assaad, R.1    Silva-Martinez, J.2
  • 30
    • 0023561471 scopus 로고
    • A micropower low-noise monolithic instrumentation amplifier for medical purposes
    • Dec.
    • M. S. J. Steyaert, W. M. C. Sansen, and Z. Chang, "A micropower low-noise monolithic instrumentation amplifier for medical purposes," IEEE J. Solid-State Circuits, vol. SC-22, pp. 1163-1168, Dec. 1987.
    • (1987) IEEE J. Solid-State Circuits , vol.SC-22 , pp. 1163-1168
    • Steyaert, M.S.J.1    Sansen, W.M.C.2    Chang, Z.3
  • 33
    • 7544228533 scopus 로고    scopus 로고
    • A digital automatic tuning technique for high-order continuous-time filters
    • Oct.
    • T. Sumesaglam and A. I. Karsilayan, "A digital automatic tuning technique for high-order continuous-time filters," IEEE Trans. Circuit Syst. I, vol. 51, pp. 1975-1984, Oct. 2004.
    • (2004) IEEE Trans. Circuit Syst. I , vol.51 , pp. 1975-1984
    • Sumesaglam, T.1    Karsilayan, A.I.2
  • 34
    • 0023362199 scopus 로고
    • A 4-MHz CMOS continuous-time filter with on-chip automatic tuning
    • F. Krummenacher and N. Joehl, "A 4-MHz CMOS continuous-time filter with on-chip automatic tuning," IEEE J. Solid-State Circuits, vol. 23, no. 6, pp. 750-758, Jun. 1988. (Pubitemid 18640877)
    • (1987) IEEE Journal of Solid-State Circuits , vol.23 , Issue.3 , pp. 750-758
    • Krummenacher, F.1    Joehl, N.2
  • 35
    • 34250748965 scopus 로고    scopus 로고
    • A low-power and compact analog CMOS processing chip for portable ECG recorders
    • DOI 10.1109/ASSCC.2005.251768, 4017634, 2005 IEEE Asian Solid-State Circuits Conference, ASSCC 2005
    • M. Shojaei-Baghini, R. K. Lal, and D. K. Sharma, "A low-power and compact analog CMOS processing chip for portable ECG recorders," in Proc. IEEE Asian Solid-State Circuits Conf., 2005, pp. 473-476. (Pubitemid 46964772)
    • (2006) 2005 IEEE Asian Solid-State Circuits Conference, ASSCC 2005 , pp. 473-476
    • Shojaei-Baghini, M.1    Lal, R.K.2    Sharma, D.K.3
  • 36
    • 77950193145 scopus 로고    scopus 로고
    • A micro-power EEG acquisition SoC with integrated feature extraction processor for a chronic seizure detection system
    • Apr.
    • N. Verma, A. Shoeb, J. Bohorquez, J. Dawson, J. Guttag, and A. P. Chandrakasan, "A micro-power EEG acquisition SoC with integrated feature extraction processor for a chronic seizure detection system," IEEE J. Solid-State Circuits, vol. 45, no. 4, pp. 804-816, Apr. 2010.
    • (2010) IEEE J. Solid-State Circuits , vol.45 , Issue.4 , pp. 804-816
    • Verma, N.1    Shoeb, A.2    Bohorquez, J.3    Dawson, J.4    Guttag, J.5    Chandrakasan, A.P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.