메뉴 건너뛰기




Volumn 80, Issue 3, 2011, Pages 677-685

Adaptive planning in intensity-modulated radiation therapy for head and neck cancers: Single-institution experience and clinical implications

Author keywords

Anatomic change; Dosimetry; Head and neck tumor; Positional change; Radiotherapy

Indexed keywords

ADAPTIVE PROTOCOL; ANATOMIC CHANGES; CERVICAL SPINE; CLINICAL MONITORING; CLINICAL TUMOR VOLUME; COMPUTED TOMOGRAPHY SCAN; DOSIMETRIC PARAMETER; GROSS TUMOR VOLUME; HEAD AND NECK; HEAD-AND-NECK CANCER; HEAD-AND-NECK TUMOR; IMAGE-GUIDED RADIATION THERAPY; INTENSITY-MODULATED RADIATION THERAPY; ORGANS AT RISKS; PATIENT POSITIONING; PLANNING CT; PLANNING TARGET VOLUMES; POSITIONAL CHANGE; SPINAL CORDS; WEIGHT LOSS;

EID: 79957575154     PISSN: 03603016     EISSN: 1879355X     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2010.03.014     Document Type: Article
Times cited : (103)

References (14)
  • 1
    • 24644465503 scopus 로고    scopus 로고
    • Intensity-modulated radiation therapy use in the U.S., 2004
    • DOI 10.1002/cncr.21284
    • L.K. Mell, A.K. Mehrotra, and A.J. Mundt Intensity-modulated radiation therapy use in the U.S., 2004 Cancer 104 2005 1296 1303 (Pubitemid 41278966)
    • (2005) Cancer , vol.104 , Issue.6 , pp. 1296-1303
    • Mell, L.K.1    Mehrotra, A.K.2    Mundt, A.J.3
  • 2
    • 0035869712 scopus 로고    scopus 로고
    • A prospective study of salivary function sparing in patients with head-and-neck cancers receiving intensity-modulated or three-dimensional radiation therapy: Initial results
    • DOI 10.1016/S0360-3016(00)01441-3, PII S0360301600014413
    • K.S. Chao, J.O. Deasy, and J. Markman A prospective study of salivary function sparing in patients with head-and-neck cancers receiving intensity-modulated or three-dimensional radiation therapy: Initial results Int J Radiat Oncol Biol Phys 49 2001 907 916 (Pubitemid 32184597)
    • (2001) International Journal of Radiation Oncology Biology Physics , vol.49 , Issue.4 , pp. 907-916
    • Chao, K.S.C.1    Deasy, J.O.2    Markman, J.3    Haynie, J.4    Perez, C.A.5    Purdy, J.A.6    Low, D.A.7
  • 4
    • 0037358291 scopus 로고    scopus 로고
    • Intensity-modulated radiation therapy (IMRT) for locally advanced paranasal sinus tumors: Incorporating clinical decisions in the optimization process
    • DOI 10.1016/S0360-3016(02)04274-8, PII S0360301602042748
    • C. Tsien, A. Eisbruch, and D. McShan Intensity-modulated radiation therapy (IMRT) for locally advanced paranasal sinus tumors: Incorporating clinical decisions in the optimization process Int J Radiat Oncol Biol Phys 55 2003 776 784 (Pubitemid 36170017)
    • (2003) International Journal of Radiation Oncology Biology Physics , vol.55 , Issue.3 , pp. 776-784
    • Tsien, C.1    Eisbruch, A.2    McShan, D.3    Kessler, M.4    Marsh, R.5    Fraass, B.6
  • 6
    • 33947526084 scopus 로고    scopus 로고
    • Future issues in highly conformal radiotherapy for head and neck cancer
    • DOI 10.1200/JCO.2006.10.4638
    • M. Feng, and A. Eisbruch Future issues in highly conformal radiotherapy for head and neck cancer J Clin Oncol 25 2007 1009 1013 (Pubitemid 350002868)
    • (2007) Journal of Clinical Oncology , vol.25 , Issue.8 , pp. 1009-1013
    • Feng, M.1    Eisbruch, A.2
  • 7
    • 58149326848 scopus 로고    scopus 로고
    • Random positional variation amongst the skull, mandible and cervical spine with treatment progression during head and neck radiotherapy
    • P.H. Ahn, A.I. Ahn, and C.J. Lee Random positional variation amongst the skull, mandible and cervical spine with treatment progression during head and neck radiotherapy Int J Radiat Oncol Biol Phys 73 2009 626 633
    • (2009) Int J Radiat Oncol Biol Phys , vol.73 , pp. 626-633
    • Ahn, P.H.1    Ahn, A.I.2    Lee, C.J.3
  • 8
    • 33645371783 scopus 로고    scopus 로고
    • Multiple regions-of-interest analysis of setup uncertainties for head-and-neck radiotherapy
    • L. Zhang, A.S. Garden, and J. Lo Multiple regions-of-interest analysis of setup uncertainties for head-and-neck radiotherapy Int J Radiat Oncol Biol Phys 64 2006 1559 1569
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , pp. 1559-1569
    • Zhang, L.1    Garden, A.S.2    Lo, J.3
  • 12
    • 34047112028 scopus 로고    scopus 로고
    • Impact of geometric uncertainties on dose distribution during intensity modulated radiotherapy of head-and-neck cancer: The need for a planning target volume and a planning organ-at-risk volume
    • O. Ballivy, W. Parker, and T. Vuong Impact of geometric uncertainties on dose distribution during intensity modulated radiotherapy of head-and-neck cancer: The need for a planning target volume and a planning organ-at-risk volume Curr Oncol 13 2006 108 115
    • (2006) Curr Oncol , vol.13 , pp. 108-115
    • Ballivy, O.1    Parker, W.2    Vuong, T.3