메뉴 건너뛰기




Volumn 58, Issue 6, 2011, Pages 1839-1845

A real-time heart rate analysis for a remote millimeter wave I-Q sensor

Author keywords

Algorithm; heart rate (HR); millimeter wave (mmW) radar

Indexed keywords

BACKGROUND NOISE; BIOMETRIC MONITORING; BODY MOVEMENTS; ELECTRONIC SYSTEM NOISE; HEART RATE (HR); HEART RATE ANALYSIS; HEART RATES; HUMAN SUBJECTS; IMAGINARY PARTS; IQ SENSORS; LEVENBERG-MARQUARDT ALGORITHM; MEDICAL DIAGNOSIS; MILLIMETER WAVE (MMW) RADAR; MMW RADAR; MMW SIGNALS; PARAMETER OPTIMIZATION METHODS; PHASE ANGLES; PHASE UNWRAPPING; Q-BRANCHES; REAL PART; RECEIVED SIGNALS; VITAL SIGN;

EID: 79956365095     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.2011.2122335     Document Type: Article
Times cited : (68)

References (31)
  • 1
    • 0019827638 scopus 로고
    • Power spectrum analysis of heart rate fluctuation: A quantitative probe of beat-to-beat cardiovascular control
    • S. Akselrod, D. Gordon, F. A. Ubel, D. C. Shannon, A. C. Berger, and R. J. Cohen, "Power spectrum analysis of heart rate fluctuation: A quantitative probe of beat-to-beat cardiovascular control," Science, vol. 213, no. 4504, pp. 220-222, 1981. (Pubitemid 11060568)
    • (1981) Science , vol.213 , Issue.4504 , pp. 220-222
    • Akselrod, S.1    Gordon, D.2    Ubel, F.A.3
  • 3
    • 0032031794 scopus 로고    scopus 로고
    • Developments in ECG acquisition, preprocessing, parameter measurement and recording
    • Mar./Apr.
    • I. K. Daskalov, I. A. Dotsinsk, and I. I. Christov, "Developments in ECG acquisition, preprocessing, parameter measurement and recording," IEEE Eng. Med. Biol. Mag., vol. 17, no. 2, pp. 50-58, Mar./Apr. 1998.
    • (1998) IEEE Eng. Med. Biol. Mag. , vol.17 , Issue.2 , pp. 50-58
    • Daskalov, I.K.1    Dotsinsk, I.A.2    Christov, I.I.3
  • 6
    • 67349186189 scopus 로고    scopus 로고
    • HRV and BPV neural network model with wavelet based algorithm calibration
    • G. Postolache, L. S. Carvalho, O. Postolache, P. Girão, and I. Rocha, "HRV and BPV neural network model with wavelet based algorithm calibration," Measurement, vol. 42, pp. 805-814, 2009.
    • (2009) Measurement , vol.42 , pp. 805-814
    • Postolache, G.1    Carvalho, L.S.2    Postolache, O.3    Girão, P.4    Rocha, I.5
  • 8
    • 0037176428 scopus 로고    scopus 로고
    • Noncontact monitoring of respiration based on an ultrasonic phase-shift reconstruction method
    • Dec.
    • K. N. Huang, Y. C. Li, and M. S. Young, "Noncontact monitoring of respiration based on an ultrasonic phase-shift reconstruction method," Biomed. Eng. Appl. Basis Commun., vol. 14, no. 6, Dec. 2002.
    • (2002) Biomed. Eng. Appl. Basis Commun. , vol.14 , Issue.6
    • Huang, K.N.1    Li, Y.C.2    Young, M.S.3
  • 10
    • 10944268678 scopus 로고    scopus 로고
    • Real-time measurement of acoustic field displacements using ultrasonic interferometry
    • DOI 10.1088/0957-0233/15/12/N01, PII S0957023304805083
    • A. Kannath and R. J. Dewhurst, "Real-time measurement of acoustic field displacements using ultrasonic interferometry," Meas. Sci. Technol., vol. 15, pp. N59-N66, 2004. (Pubitemid 40015048)
    • (2004) Measurement Science and Technology , vol.15 , Issue.12
    • Kannath, A.1    Dewhurst, R.J.2
  • 11
    • 36049012767 scopus 로고    scopus 로고
    • Measurement of human heartbeat and respiration signals using phase detection radar
    • H. J. Kim, K. H. Kim, Y. S. Hong, and J. J. Choi, "Measurement of human heartbeat and respiration signals using phase detection radar," Rev. Sci. Instrum., vol. 78, p. 104703, 2007.
    • (2007) Rev. Sci. Instrum. , vol.78 , pp. 104703
    • Kim, H.J.1    Kim, K.H.2    Hong, Y.S.3    Choi, J.J.4
  • 12
    • 51849132622 scopus 로고    scopus 로고
    • Wireless noncontact detection of heartbeat and respiration using low-power microwave radar sensor
    • Dec.
    • J. Lin and C. Li, "Wireless noncontact detection of heartbeat and respiration using low-power microwave radar sensor," in Proc. Asia-Pacific Microwave Conf., Dec. 2007, pp. 1-4.
    • (2007) Proc. Asia-Pacific Microwave Conf. , pp. 1-4
    • Lin, J.1    Li, C.2
  • 13
    • 57849157376 scopus 로고    scopus 로고
    • Random body movement cancellation in Doppler radar vital sign detection
    • Dec.
    • C. Li and J. Lin, "Random body movement cancellation in Doppler radar vital sign detection," IEEE Trans. Microwave Theory Tech., vol. 56, no. 12, pp. 3143-3152, Dec. 2008.
    • (2008) IEEE Trans. Microwave Theory Tech. , vol.56 , Issue.12 , pp. 3143-3152
    • Li, C.1    Lin, J.2
  • 14
    • 69949088170 scopus 로고    scopus 로고
    • Millimeter wave radar for remote measurement of vital signs
    • D. T. Petkie, C. Benton, and E. Bryan, "Millimeter wave radar for remote measurement of vital signs," in Proc. IEEE Radar Conf., May, 2009, pp. 4-8.
    • (2009) Proc. IEEE Radar Conf., May , pp. 4-8
    • Petkie, D.T.1    Benton, C.2    Bryan, E.3
  • 17
    • 0026203883 scopus 로고
    • Applications of adaptive filtering to ECG analysis: Noise cancellation and arrhythmia detection
    • Aug.
    • N. V. Thakor and Y.-S. Zhu, "Applications of adaptive filtering to ECG analysis: Noise cancellation and arrhythmia detection," IEEE Trans. Biomed. Eng., vol. 38, no. 8, pp. 785-794, Aug. 1991.
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , Issue.8 , pp. 785-794
    • Thakor, N.V.1    Zhu, Y.-S.2
  • 19
    • 0031294929 scopus 로고    scopus 로고
    • Development of QRS detection method for real-time ambulatory cardiac monitor
    • IEEE/EMBS 19th Int. Conf., Oct. 30-Nov.
    • H. H. So and K. L. Chan, "Development of QRS detection method for real-time ambulatory cardiac monitor," in Proc. IEEE/EMBS 19th Int. Conf., Oct. 30-Nov. 2, 1997, pp. 289-292.
    • (1997) Proc. , vol.2 , pp. 289-292
    • So, H.H.1    Chan, K.L.2
  • 20
    • 29144488963 scopus 로고    scopus 로고
    • A novel QRS detection algorithm applied to the analysis for heart rate variability of patients with sleep apnea
    • Oct.
    • R. Lee, I.-C. Chou, C.-C Lai, M.-H. Liu, and M.-J. Chiu, "A novel QRS detection algorithm applied to the analysis for heart rate variability of patients with sleep apnea," Biomed. Eng. Appl., Basis Commun., vol. 17, no. 5, Oct. 2005.
    • (2005) Biomed. Eng. Appl., Basis Commun. , vol.17 , Issue.5
    • Lee, R.1    Chou, I.-C.2    Lai, C.-C.3    Liu, M.-H.4    Chiu, M.-J.5
  • 21
    • 33847120849 scopus 로고    scopus 로고
    • Method to filter ECGs and evaluate clinical parameter distortion using realistic ECG model parameter fitting
    • DOI 10.1109/CIC.2005.1588204, 1588204, Computers in Cardiology, 2005
    • G. D. Clifford and P. E. McSharry, "Method to filter ECGs and evaluate clinical parameter distortion using realistic ECG model parameter fitting," Comput. Cardiol., vol. 32, pp. 715-718, 2005. (Pubitemid 46276762)
    • (2005) Computers in Cardiology , vol.32 , pp. 715-718
    • Clifford, G.D.1    McSharry, P.E.2
  • 22
    • 0027842081 scopus 로고
    • Matching pursuits with time-frequency dictionaries
    • Dec.
    • S. G. Mallat and Z. Zhang, "Matching pursuits with time-frequency dictionaries," IEEE Trans. Signal Process., vol. 41, no. 12, pp. 3397-3415, Dec. 1993.
    • (1993) IEEE Trans. Signal Process. , vol.41 , Issue.12 , pp. 3397-3415
    • Mallat, S.G.1    Zhang, Z.2
  • 23
    • 65349171929 scopus 로고    scopus 로고
    • Time-frequency component analysis of somatosensory evoked potentials in rats
    • Z.-G. Zhang, J.-L. Yang, S.-C. Chan, K. D.-K. Luk, and Y. Hu, "Time-frequency component analysis of somatosensory evoked potentials in rats," BioMed. Eng. OnLine, vol. 8, no. 4, pp. 1-10, 2009.
    • (2009) BioMed. Eng. OnLine , vol.8 , Issue.4 , pp. 1-10
    • Zhang, Z.-G.1    Yang, J.-L.2    Chan, S.-C.3    Luk, K.D.-K.4    Hu, Y.5
  • 24
    • 0000873069 scopus 로고
    • A method for the solution of certain problems in least squares
    • K. Levenberg, "A method for the solution of certain problems in least squares," Quart. Appl. Math., vol. 2, pp. 164-168, 1944.
    • (1944) Quart. Appl. Math. , vol.2 , pp. 164-168
    • Levenberg, K.1
  • 25
    • 0000169232 scopus 로고
    • An algorithm for least-squares estimation of nonlinear parameters
    • D. Marquardt, "An algorithm for least-squares estimation of nonlinear parameters," SIAM J. Appl. Math., vol. 11, pp. 431-441, 1963.
    • (1963) SIAM J. Appl. Math. , vol.11 , pp. 431-441
    • Marquardt, D.1
  • 26
    • 0025438968 scopus 로고
    • Efficient modeling parameter extraction for dual Pearson approach to simulation of implanted impurity profiles in silicon
    • C. Park, K. M. Klein, and Al F. Tasch, "Efficient modeling parameter extraction for dual Pearson approach to simulation of implanted impurity profiles in silicon," Solid-State Electron., vol. 33, no. 6, pp. 645-650, Jun. 1990. (Pubitemid 20735169)
    • (1990) Solid-State Electronics , vol.33 , Issue.6 , pp. 645-650
    • Park Changhae1    Klein Kevin, M.2    Tasch Al, F.3
  • 27
    • 22844440750 scopus 로고    scopus 로고
    • The use of the Levenberg-Marquardt curve-fitting algorithm in pharmacokinetic modelling of DCE-MRI data
    • DOI 10.1088/0031-9155/50/9/N02
    • T. S. Ahearn, R. T. Staff, T. W. Redpath, and S. I. K. Semple, "The use of the Levenberg-Marquardt curve-fitting algorithm in pharmacokinetic modeling of DCE-MRI data," Phys. Med. Biol., vol. 50, pp. N85-N92, 2005. (Pubitemid 41237183)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.9
    • Ahearn, T.S.1    Staff, R.T.2    Redpath, T.W.3    Semple, S.I.K.4
  • 28
    • 0031032388 scopus 로고    scopus 로고
    • Noninvasive assessment of the ventricular relaxation time constant (τ) in humans by Doppler echocardiography
    • G. M. Scalia, N. L. Greenberg, P. M. McCarthy, J. D. Thomas, and P. M. Vandervoort, "Noninvasive assessment of the ventricular relaxation time constant (tau) in humans by Doppler echocardiography," Circulation, vol. 95, pp. 151-155, 1997. (Pubitemid 27029956)
    • (1997) Circulation , vol.95 , Issue.1 , pp. 151-155
    • Scalia, G.M.1    Greenberg, N.L.2    McCarthy, P.M.3    Thomas, J.D.4    Vandervoort, P.M.5
  • 30
    • 57349171370 scopus 로고    scopus 로고
    • Complex signal demodulation and random body movement cancellation techniques for noncontact vital sign detection
    • Atlanta, GA, Jun.
    • C. Li and J. Lin, "Complex signal demodulation and random body movement cancellation techniques for noncontact vital sign detection," in Proc. IEEE MTT-S Int. Microw. Symp. Dig.,. Atlanta, GA, Jun. 2008, pp. 567-570.
    • (2008) Proc. IEEE MTT-S Int. Microw. Symp. Dig. , pp. 567-570
    • Li, C.1    Lin, J.2
  • 31
    • 34548398132 scopus 로고    scopus 로고
    • Sensitive ultrasonic vi-brometer for very low frequency applications
    • B. Cretin, P. Vairac, N. Jachez, and J. Pergaud, "Sensitive ultrasonic vi-brometer for very low frequency applications," Rev. Sci. Instrum., vol. 78, p. 085112, 2007.
    • (2007) Rev. Sci. Instrum. , vol.78 , pp. 085112
    • Cretin, B.1    Vairac, P.2    Jachez, N.3    Pergaud, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.