메뉴 건너뛰기




Volumn 7981, Issue , 2011, Pages

Transformer winding temperature estimation based on tank surface temperature

Author keywords

fiber optic sensors; modeling; Power transformers; surface temperature; thermocouples; winding temperature

Indexed keywords

DIRECT MEASUREMENT; ELECTRICAL GRIDS; FIBER OPTIC TEMPERATURE SENSOR; HIGH TEMPERATURE; INFORMED DECISION; MODELING; REMAINING LIFE; SURFACE TEMPERATURE; SURFACE TEMPERATURES; TEMPERATURE ESTIMATION; THERMAL PERFORMANCE; TRANSFORMER TANKS;

EID: 79956325363     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.880615     Document Type: Conference Paper
Times cited : (4)

References (7)
  • 1
    • 0025398470 scopus 로고
    • Direct measurement of the hot-spot temperature of transformers
    • Cigre Working Group 12-09
    • Cigre Working Group 12-09, "Direct measurement of the hot-spot temperature of transformers," Électra 129, 48-51 (1990).
    • (1990) Électra , vol.129 , pp. 48-51
  • 2
    • 0037250663 scopus 로고    scopus 로고
    • Thermal overload tests on a 400-MVA power transformer with a special 2.5-p.u. Short time loading capability
    • Nordman, H. and Lahtinen, M., "Thermal overload tests on a 400-MVA power transformer with a special 2.5-p.u. Short time loading capability," IEEE Transactions on Power Delivery 18, 107-112 (2003).
    • (2003) IEEE Transactions on Power Delivery , vol.18 , pp. 107-112
    • Nordman, H.1    Lahtinen, M.2
  • 3
    • 79956320373 scopus 로고    scopus 로고
    • Loading guide for oil-immersed power transformers
    • IEC
    • IEC, [IEC 60076-7: Power transformers - Part 7: Loading guide for oil-immersed power transformers], (2005).
    • (2005) IEC 60076-7: Power Transformers , Issue.PART 7
  • 5
    • 0030835196 scopus 로고    scopus 로고
    • An improved transformer top oil temperature model for use in an on-line monitoring and diagnostic system
    • Lesieutre, B. C., Hagman, W. H. and Kirtley, J. L., Jr., "An improved transformer top oil temperature model for use in an on-line monitoring and diagnostic system," IEEE Transactions on Power Delivery 12, 249-256 (1997).
    • (1997) IEEE Transactions on Power Delivery , vol.12 , pp. 249-256
    • Lesieutre, B.C.1    Hagman, W.H.2    Kirtley Jr., J.L.3
  • 6
    • 0035304359 scopus 로고    scopus 로고
    • A fundamental approach to transformer thermal modeling. I. Theory and equivalent circuit
    • Swift, G., Molinski, T. S. and Lehn, W., "A fundamental approach to transformer thermal modeling. I. Theory and equivalent circuit," IEEE Transactions on Power Delivery 16, 171-175 (2001).
    • (2001) IEEE Transactions on Power Delivery , vol.16 , pp. 171-175
    • Swift, G.1    Molinski, T.S.2    Lehn, W.3
  • 7
    • 0035304067 scopus 로고    scopus 로고
    • A fundamental approach to transformer thermal modeling. II. Field verification
    • Swift, G., Molinski, T. S., Bray, R. and Menzies, R., "A fundamental approach to transformer thermal modeling. II. Field verification," IEEE Transactions on Power Delivery 16, 176-180 (2001).
    • (2001) IEEE Transactions on Power Delivery , vol.16 , pp. 176-180
    • Swift, G.1    Molinski, T.S.2    Bray, R.3    Menzies, R.4