-
1
-
-
0034949450
-
Microalbuminuria: What is it? why is it important? What should be done about it?
-
GL Bakris 2001 Microalbuminuria: What is it? Why is it important? What should be done about it? J Clin Hypertens 3 99 102 10.1111/j.1524-6175.2001. 00442.x (Pubitemid 32605764)
-
(2001)
Journal of Clinical Hypertension
, vol.3
, Issue.2
, pp. 99-102
-
-
Bakris, G.L.1
-
2
-
-
0032884749
-
Measuring agreement in method comparison studies
-
DOI 10.1191/096228099673819272
-
JM Bland DG Altman 1999 Measuring agreement in method comparison studies Stat Methods Med Res 8 135 160 10.1191/096228099673819272 (Pubitemid 29425900)
-
(1999)
Statistical Methods in Medical Research
, vol.8
, Issue.2
, pp. 135-160
-
-
Bland, J.M.1
Altman, D.G.2
-
3
-
-
33750302343
-
Albumin to creatinine ratio in 2 random urine samples was an accurate screening test for albuminuria in diabetic pregnancies: Commentary
-
DOI 10.1136/ebm.11.5.154
-
C Bryson L Dalrymple 2006 Albumin to creatinine ratio in 2 random urine samples was an accurate screening test for albuminuria in diabetic pregnancies Evid Based Med 11 154 10.1136/ebm.11.5.154 (Pubitemid 44613272)
-
(2006)
Evidence-Based Medicine
, vol.11
, Issue.5
, pp. 154
-
-
Bryson, C.L.1
Dalrymple, L.2
-
4
-
-
55949087415
-
Simultaneous determination of guanidinoacetate, creatine and creatinine in urine and plasma by un-derivatized liquid chromatography-tandem mass spectrometry
-
10.1258/acb.2008.008029
-
RS Carling SL Hogg 2008 Simultaneous determination of guanidinoacetate, creatine and creatinine in urine and plasma by un-derivatized liquid chromatography-tandem mass spectrometry Ann Clin Biochem 45 575 584 10.1258/acb.2008.008029
-
(2008)
Ann Clin Biochem
, vol.45
, pp. 575-584
-
-
Carling, R.S.1
Hogg, S.L.2
-
5
-
-
33750451243
-
Chip Electrophoresis as a method for quantifying total microalbuminuria
-
DOI 10.1373/clinchem.2006.072801
-
OTM Chan DA Herold 2006 Chip electrophoresis as a method for quantifying total microalbuminuria Clin Chem 52 2141 2146 10.1373/clinchem.2006.072801 (Pubitemid 44658229)
-
(2006)
Clinical Chemistry
, vol.52
, Issue.11
, pp. 2141-2146
-
-
Chan, O.T.M.1
Herold, D.A.2
-
6
-
-
0026348689
-
Borderline increases in albumin excretion rate and the relation to glycemic control in subjects with type I diabetes
-
HP Chase G Marshall SK Garg S Harris I Osberg 1991 Borderline increases in albumin excretion rate and the relation to glycemic control in subjects with type I diabetes Clin Chem 37 2048 2052 (Pubitemid 21925899)
-
(1991)
Clinical Chemistry
, vol.37
, Issue.12
, pp. 2048-2052
-
-
Chase, H.P.1
Marshall, G.2
Garg, S.K.3
Harris, S.4
Osberg, I.5
-
7
-
-
0023617551
-
Comparison of overnight, morning and 24-hour urine collections in the assessment of diabetic microalbuminuria
-
O Eshøj B Feldt-Rasmussen ML Larsen EF Mogensen 1987 Comparison of overnight, morning and 24-hour urine collections in the assessment of diabetic microalbuminuria Diabet Med 4 531 533 10.1111/j.1464-5491.1987.tb00924.x (Pubitemid 17163029)
-
(1987)
Diabetic Medicine
, vol.4
, Issue.6
, pp. 531-533
-
-
Eshoj, O.1
Feldt-Rasmussen, B.2
Larsen, M.L.3
Mogensen, E.F.4
-
8
-
-
59849114879
-
Development of a creatinine enzyme-based bar-code-style lateral-flow assay
-
10.1007/s00216-008-2551-5
-
KK Fung CPY Chan R Renneberg 2009 Development of a creatinine enzyme-based bar-code-style lateral-flow assay Anal Bioanal Chem 393 1281 1287 10.1007/s00216-008-2551-5
-
(2009)
Anal Bioanal Chem
, vol.393
, pp. 1281-1287
-
-
Fung, K.K.1
Chan, C.P.Y.2
Renneberg, R.3
-
9
-
-
23644434281
-
Towards microalbuminuria determination on a disposable diagnostic microchip with integrated fluorescence detection based on thin-film organic light emitting diodes
-
DOI 10.1039/b504551g
-
O Hofmann X Wang JC deMello DDC Bradley AJ deMello 2005 Towards microalbuminuria determination on a disposable diagnostic microchip with integrated fluorescence detection based on thin-film organic light emitting diodes Lab Chip 5 863 868 10.1039/b504551g (Pubitemid 41117314)
-
(2005)
Lab on a Chip - Miniaturisation for Chemistry and Biology
, vol.5
, Issue.8
, pp. 863-868
-
-
Hofmann, O.1
Wang, X.2
DeMello, J.C.3
Bradley, D.D.C.4
DeMello, A.J.5
-
10
-
-
0014258678
-
Estimation of creatinine by the Jaffe reaction: A comparison of three methods
-
H Husdan A Rapoport 1968 Estimation of creatinine by the Jaffe reaction: a comparison of three methods Clin Chem 14 222 238
-
(1968)
Clin Chem
, vol.14
, pp. 222-238
-
-
Husdan, H.1
Rapoport, A.2
-
11
-
-
33746370131
-
Albumin-to-creatinine ratio in random urine samples might replace 24-h urine collections in screening for micro- and macroalbuminuria in pregnant woman with type 1 diabetes
-
TI Justesen JLA Petersen P Ekbom P Damm ER Mathiesen 2006 Albumin-to-creatinine ratio in random urine samples might replace 24-h urine collections in screening for micro- and macroalbuminuria in pregnant woman with type 1 diabetes Diabetes Care 29 924 925 10.2337/diacare.29.04.06.dc06-1555 (Pubitemid 44115318)
-
(2006)
Diabetes Care
, vol.29
, Issue.4
, pp. 924-925
-
-
Justesen, T.I.1
Petersen, J.L.A.2
Ekbom, P.3
Damm, P.4
Mathiesen, E.R.5
-
12
-
-
0033485870
-
Quantitative analysis of molecular interaction in a microfluidic channel: The T-sensor
-
AEB Kamholz BH Weigl BA Finlayson P Yager 1999 Quantitative analysis of molecular interaction in a microfluidic channel:∈the T-sensor Anal Chem 71 5340 5347 10.1021/ac990504j (Pubitemid 129563252)
-
(1999)
Analytical Chemistry
, vol.71
, Issue.23
, pp. 5340-5347
-
-
Kamholz, A.E.1
Weigl, B.H.2
Finlayson, B.A.3
Yager, P.4
-
13
-
-
0026601183
-
Laser-induced fluorescence determination of albumin using longwave absorbing molecular probes
-
10.1016/0003-2697(92)90462-G
-
MA Kessler OS Wolfbeis 1992 Laser-induced fluorescence determination of albumin using longwave absorbing molecular probes Anal Biochem 200 254 259 10.1016/0003-2697(92)90462-G
-
(1992)
Anal Biochem
, vol.200
, pp. 254-259
-
-
Kessler, M.A.1
Wolfbeis, O.S.2
-
14
-
-
0030975133
-
Microalbuminuria and borderline-increased albumin excretion determined with a centrifugal analyzer and the Albumin Blue 580 fluorescence assay
-
MA Kessler A Meinitzer W Petek OS Wolfbeis 1997 Microalbuminuria and borderline-increased albumin excretion determined with a centrifugal analyzer and the Albumin Blue 580 fluorescence assay Clin Chem 43 996 1002 (Pubitemid 27246991)
-
(1997)
Clinical Chemistry
, vol.43
, Issue.6
, pp. 996-1002
-
-
Kessler, M.A.1
Meinitzer, A.2
Peter, W.3
Wolfbeis, O.S.4
-
15
-
-
0031570351
-
Albumin blue 580 fluorescence assay for albumin
-
DOI 10.1006/abio.1997.2113
-
MA Kessler A Meinitzer OS Wolfbeis 1997 Albumin Blue 580 fluorescence assay for albumin Anal Biochem 248 180 182 10.1006/abio.1997.2113 (Pubitemid 27218237)
-
(1997)
Analytical Biochemistry
, vol.248
, Issue.1
, pp. 180-182
-
-
Kessler, M.A.1
Meinitzer, A.2
Wolfbeis, O.S.3
-
16
-
-
70450085157
-
A microfabricated CE chip for DNA pre-concentration and separation utilizing a normally closed valve
-
10.1002/elps.200900112
-
CH Kuo JH Wang GB Lee 2009 A microfabricated CE chip for DNA pre-concentration and separation utilizing a normally closed valve Electrophoresis 30 3228 3235 10.1002/elps.200900112
-
(2009)
Electrophoresis
, vol.30
, pp. 3228-3235
-
-
Kuo, C.H.1
Wang, J.H.2
Lee, G.B.3
-
17
-
-
4544354361
-
Microchip capillary electrophoresis with electrochemical detector for precolumn enzymatic analysis of glucose, creatinine, uric acid and ascorbic acid in urine and serum
-
10.1016/j.talanta.2004.03.046
-
HL Lee SC Chen 2004 Microchip capillary electrophoresis with electrochemical detector for precolumn enzymatic analysis of glucose, creatinine, uric acid and ascorbic acid in urine and serum Talanta 64 750 757 10.1016/j.talanta.2004.03.046
-
(2004)
Talanta
, vol.64
, pp. 750-757
-
-
Lee, H.L.1
Chen, S.C.2
-
18
-
-
0001106451
-
A simplified equation to predict glomerular filtration rate from serum creatinine (Abstr)
-
AS Levey T Greene JW Kusek GL Beck 2000 A simplified equation to predict glomerular filtration rate from serum creatinine (Abstr) J Am Soc Nephrol 11 155A
-
(2000)
J Am Soc Nephrol
, vol.11
-
-
Levey, A.S.1
Greene, T.2
Kusek, J.W.3
Beck, G.L.4
-
19
-
-
10044265053
-
Micromachined polymerase chain reaction system for multiple DNA amplification of upper respiratory tract infectious diseases
-
DOI 10.1016/j.bios.2004.05.006, PII S0956566304002362
-
CS Liao GB Lee JJ Wu CC Chang TM Hsieh FC Huang CH Luo 2005 Micromachined polymerase chain reaction system for multiple DNA amplification of upper respiratory tract infectious diseases Biosens Bioelectron 20 1341 1348 10.1016/j.bios.2004.05.006 (Pubitemid 39601665)
-
(2005)
Biosensors and Bioelectronics
, vol.20
, Issue.7
, pp. 1341-1348
-
-
Liao, C.-S.1
Lee, G.-B.2
Wu, J.-J.3
Chang, C.-C.4
Hsieh, T.-M.5
Huang, F.-C.6
Luo, C.-H.7
-
20
-
-
24144455970
-
A rapid three-dimensional vortex micromixer utilizing self-rotation effects under low Reynolds number conditions
-
DOI 10.1088/0960-1317/15/5/006
-
CH Lin CH Tsai LM Fu 2005 A rapid three-dimensional vortex micromixer utilizing self-rotation effects under low Reynolds number conditions J Micromech Microeng 15 935 943 10.1088/0960-1317/15/5/006 (Pubitemid 41237422)
-
(2005)
Journal of Micromechanics and Microengineering
, vol.15
, Issue.5
, pp. 935-943
-
-
Lin, C.-H.1
Tsai, C.-H.2
Fu, L.-M.3
-
21
-
-
79955956190
-
Sample preconcentration in microfluidic devices
-
doi:10.1007/s1040401006619
-
Lin CC, Hsu JL, Lee GB (2010a) Sample preconcentration in microfluidic devices. Microfluid Nanofluid. doi: 10.1007/s1040401006619
-
(2010)
Microfluid Nanofluid
-
-
Lin, C.C.1
Hsu, J.L.2
Lee, G.B.3
-
22
-
-
78049277826
-
An integrated microfluidic chip for non-immunological determination of urinary albumin
-
10.1007/s10544-010-9443-0
-
CC Lin CC Tseng GB Lee 2010 An integrated microfluidic chip for non-immunological determination of urinary albumin Biomed Microdevices 12 887 896 10.1007/s10544-010-9443-0
-
(2010)
Biomed Microdevices
, vol.12
, pp. 887-896
-
-
Lin, C.C.1
Tseng, C.C.2
Lee, G.B.3
-
23
-
-
0015425245
-
Simple, rapid, kinetic method for serum creatinine measurement
-
JA Lustgarten RE Wenk 1972 Simple, rapid, kinetic method for serum creatinine measurement Clin Chem 18 1419 1422
-
(1972)
Clin Chem
, vol.18
, pp. 1419-1422
-
-
Lustgarten, J.A.1
Wenk, R.E.2
-
26
-
-
0002109130
-
Prevalence of hypertension and microalbuminuria in adult type 1 (insulin-dependent) diabetic patients without renal failure in Italy. I. Validation of screening techniques to detect microalbuminuria
-
10.1007/BF00573481
-
R Mangili G Deferrari U Mario O Giampietro R Navalesi R Nosadini G Rigamonti G Crepaldi 1992 Prevalence of hypertension and microalbuminuria in adult type 1 (insulin-dependent) diabetic patients without renal failure in Italy. I. Validation of screening techniques to detect microalbuminuria Acta Diabetol 29 156 166 10.1007/BF00573481
-
(1992)
Acta Diabetol
, vol.29
, pp. 156-166
-
-
Mangili, R.1
Deferrari, G.2
Mario, U.3
Giampietro, O.4
Navalesi, R.5
Nosadini, R.6
Rigamonti, G.7
Crepaldi, G.8
-
27
-
-
0025207507
-
Miniaturized total chemical analysis systems. A novel concept for chemical sensing
-
A Manz N Graber HM Widmer 1990 Miniaturized total chemical analysis systems: a novel concept for chemical sensing Sensor Actuat B 1 244 248 10.1016/0925-4005(90)80209-I (Pubitemid 20699475)
-
(1990)
Sensors and Actuators, B: Chemical
, vol.B1
, Issue.1-6
, pp. 244-248
-
-
Manz, A.1
Graber, N.2
Widmer, H.M.3
-
28
-
-
56549118219
-
An integrated microfluidic platform for sensitive and rapid detection of biological toxins
-
10.1039/b815152k
-
RJ Meagher AV Hatch RF Renzi AK Singh 2008 An integrated microfluidic platform for sensitive and rapid detection of biological toxins Lab Chip 8 2046 2053 10.1039/b815152k
-
(2008)
Lab Chip
, vol.8
, pp. 2046-2053
-
-
Meagher, R.J.1
Hatch, A.V.2
Renzi, R.F.3
Singh, A.K.4
-
29
-
-
0023134379
-
Microalbuminuria as a predictor of clinical diabetic nephropathy
-
CE Mogensen 1987 Microalbuminuria as a predictor of clinical diabetic nephropathy Kidney Int 31 673 689 10.1038/ki.1987.50 (Pubitemid 17012586)
-
(1987)
Kidney International
, vol.31
, Issue.2
, pp. 673-689
-
-
Mogensen, C.E.1
-
30
-
-
10744228041
-
Biological variability of albumin excretion rate and albumin-to- creatinine ratio in hypertensive type 2 diabetic Patients
-
10.1515/CCLM.2003.188
-
A Mosca R Paleari F Ceriotti A Lapolla D Fedele 2005 Biological variability of albumin excretion rate and albumin-to-creatinine ratio in hypertensive type 2 diabetic Patients Clin Chem Lab Med 41 1229 1233 10.1515/CCLM.2003.188
-
(2005)
Clin Chem Lab Med
, vol.41
, pp. 1229-1233
-
-
Mosca, A.1
Paleari, R.2
Ceriotti, F.3
Lapolla, A.4
Fedele, D.5
-
32
-
-
33644696674
-
Validation of a liquid chromatography tandem mass spectrometry assay for serum creatinine and comparison with enzymatic and Jaffe methods
-
DOI 10.1258/000456306776021544
-
LJ Owen JE Wear BG Keevil 2006 Validation of a liquid chromatography tandem mass spectrometry assay for serum creatinine and comparison with enzymatic and Jaffe methods Ann Clin Biochem 43 118 123 10.1258/ 000456306776021544 (Pubitemid 43332332)
-
(2006)
Annals of Clinical Biochemistry
, vol.43
, Issue.2
, pp. 118-123
-
-
Owen, L.J.1
Wear, J.E.2
Keevil, B.G.3
-
33
-
-
38849087943
-
BioFET sensor for detection of albumin in urine
-
DOI 10.1049/el:20083551
-
KM Park SK Lee YS Sohn SY Choi 2008 BioFET sensor for detection of albumin in urine Electron Lett 44 185 186 10.1049/el:20083551 (Pubitemid 351190968)
-
(2008)
Electronics Letters
, vol.44
, Issue.3
, pp. 185-186
-
-
Park, K.-M.1
Lee, S.-K.2
Sohn, Y.-S.3
Choi, S.-Y.4
-
34
-
-
0021045350
-
New biometrical procedures for testing the equality of measurements from two different analytical methods
-
H Passing W Bablok 1983 New biometrical procedures for testing the equality of measurements from two different analytical methods J Clin Chem Clin Biochem 21 709 720
-
(1983)
J Clin Chem Clin Biochem
, vol.21
, pp. 709-720
-
-
Passing, H.1
Bablok, W.2
-
35
-
-
0034103306
-
Assay of creatinine using the peroxidase activity of copper-creatinine complexes
-
DOI 10.1016/S0009-9120(99)00086-7, PII S0009912099000867
-
MJ Pugia JA Lott JF Wallace TK Cast LD Bierbaum 2000 Assay of creatinine using the peroxidase activity of copper-creatinine complexes Clin Biochem 33 63 70 10.1016/S0009-9120(99)00086-7 (Pubitemid 30313045)
-
(2000)
Clinical Biochemistry
, vol.33
, Issue.1
, pp. 63-70
-
-
Pugia, M.J.1
Lott, J.A.2
Wallace, J.F.3
Cast, T.K.4
Bierbaum, L.D.5
-
36
-
-
4544346167
-
Creatinine biosensor based on ammonium ion selective electrode and its application in flow-injection analysis
-
10.1016/j.talanta.2004.03.033
-
A Radomska E Bodenszac BS Gła R Koncki 2004 Creatinine biosensor based on ammonium ion selective electrode and its application in flow-injection analysis Talanta 64 603 608 10.1016/j.talanta.2004.03.033
-
(2004)
Talanta
, vol.64
, pp. 603-608
-
-
Radomska, A.1
Bodenszac, E.2
Gła, B.S.3
Koncki, R.4
-
37
-
-
4143079212
-
Very fast and direct capillary zone electrophoresis method for the determination of creatinine and creatine in human urine
-
DOI 10.1016/j.aca.2004.05.058, PII S0003267004006683
-
JJ Rodríguez J Berzas G Castañeda N Mora MJ Rodríguez 2004 Very fast and direct capillary zone electrophoresis method for the determination of creatinine and creatine in human urine Anal Chim Acta 521 53 59 10.1016/j.aca.2004.05.058 (Pubitemid 39092877)
-
(2004)
Analytica Chimica Acta
, vol.521
, Issue.1
, pp. 53-59
-
-
Rodriguez, J.1
Berzas, J.J.2
Castaneda, G.3
Mora, N.4
Rodriguez, M.J.5
-
38
-
-
0025359197
-
Microalbuminuria in diabetes mellitus: Review and recommendations for the measurement of albumin in urine
-
DJF Rowe A Dawnay GF Watts 1990 Microalbuminuria in diabetes mellitus: review and recommendation for the measurement of albumin in urine Ann Clin Biochem 27 297 312 (Pubitemid 20210076)
-
(1990)
Annals of Clinical Biochemistry
, vol.27
, Issue.4
, pp. 297-312
-
-
Rowe, D.J.F.1
Dawnay, A.2
Watts, G.F.3
-
39
-
-
0029024608
-
Routine assay of creatinine in newborn baby urine by spectrophotometric flow-injection analysis
-
10.1016/0003-2670(94)00516-O
-
T Sakai H Ohta N Ohno J Imai 1995 Routine assay of creatinine in newborn baby urine by spectrophotometric flow-injection analysis Anal Chim Acta 308 446 450 10.1016/0003-2670(94)00516-O
-
(1995)
Anal Chim Acta
, vol.308
, pp. 446-450
-
-
Sakai, T.1
Ohta, H.2
Ohno, N.3
Imai, J.4
-
42
-
-
0018423965
-
2 microglobulin in insulin-dependent diabetes
-
GC Viberti JC Pickup D Phil RJ Jarrett H Keen 1979 Effect of control of blood glucose on urinary excretion of albumin and β2 microglobulin in insulin-dependent diabetes New Engl J Med 300 638 641 10.1056/ NEJM197903223001202 (Pubitemid 9140175)
-
(1979)
New England Journal of Medicine
, vol.300
, Issue.12
, pp. 638-641
-
-
Viberti, G.C.1
Pickup, J.C.2
Jarrett, R.J.3
Keen, H.4
-
43
-
-
0022180983
-
Proliferative diabetic retinopathy: At risk patients identified by early detection of microalbuminuria
-
J Vigstrup CE Mogensen 1985 Proliferative diabetic retinopathy: at risk patients identified by early detection of microalbuminuria Acta Ophthalmol 63 530 534 (Pubitemid 16249898)
-
(1985)
Acta Ophthalmologica
, vol.63
, Issue.5
, pp. 530-534
-
-
Vigstrup, J.1
Mogensen, C.E.2
-
45
-
-
0025893319
-
Interferences in current methods for measurements of creatinine
-
JA Weber AP van Zanten 1991 Interferences in current methods for measurements of creatinine Clin Chem 37 695 700 (Pubitemid 21892711)
-
(1991)
Clinical Chemistry
, vol.37
, Issue.5
, pp. 695-700
-
-
Weber, J.A.1
Van Zanten, A.P.2
-
46
-
-
67349245781
-
A pneumatic micropump incorporated with a normally closed valve capable of generating a high pumping rate and a high back pressure
-
10.1007/s10404-008-0356-7
-
YN Yang SK Hsiung GB Lee 2009 A pneumatic micropump incorporated with a normally closed valve capable of generating a high pumping rate and a high back pressure Microfluid Nanofluid 6 823 833 10.1007/s10404-008-0356-7
-
(2009)
Microfluid Nanofluid
, vol.6
, pp. 823-833
-
-
Yang, Y.N.1
Hsiung, S.K.2
Lee, G.B.3
-
47
-
-
61849100543
-
A vortex-type micromixer utilizing pneumatically driven membranes
-
10.1088/0960-1317/19/3/035020
-
SY Yang JL Lin GB Lee 2009 A vortex-type micromixer utilizing pneumatically driven membranes J Micromech Microeng 19 035020 0350208 10.1088/0960-1317/19/3/035020
-
(2009)
J Micromech Microeng
, vol.19
, pp. 035020-0350208
-
-
Yang, S.Y.1
Lin, J.L.2
Lee, G.B.3
|