메뉴 건너뛰기




Volumn 32, Issue 5, 2011, Pages 923-928

Use of CT angiography in comparison with other imaging techniques for the determination of embolus and remnant size in experimental aneurysms embolized with hydrogel filaments

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; ARTIFICIAL EMBOLISM; COIL EMBOLIZATION; COMMON CAROTID ARTERY; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTROLLED STUDY; DIGITAL SUBTRACTION ANGIOGRAPHY; FOLLOW UP; HISTOLOGY; HYDROGEL; INTERMETHOD COMPARISON; INTRACRANIAL ANEURYSM; MAGNETIC RESONANCE ANGIOGRAPHY; NEUROIMAGING; NONHUMAN; RABBIT;

EID: 79956124667     PISSN: 01956108     EISSN: 1936959X     Source Type: Journal    
DOI: 10.3174/ajnr.A2554     Document Type: Article
Times cited : (4)

References (20)
  • 1
    • 26944466840 scopus 로고    scopus 로고
    • International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: A randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion
    • DOI 10.1016/S0140-6736(05)67214-5
    • Molyneux AJ, Kerr RS, Yu LM, et al. International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion. Lancet 2005;366:809-17 (Pubitemid 41557380)
    • (2005) Lancet , vol.366 , Issue.9488 , pp. 809-817
    • Molyneux, A.J.1    Kerr, R.S.2    Yu, L.-M.3    Clarke, M.4    Sneade, M.5    Yarnold, J.A.6    Sandercock, P.7
  • 2
    • 0034831339 scopus 로고    scopus 로고
    • Endovascular treatment of unruptured aneurysms
    • Roy D, Milot G, Raymond J. Endovascular treatment of unruptured aneurysms. Stroke 2001;32:1998-2004 (Pubitemid 32868087)
    • (2001) Stroke , vol.32 , Issue.9 , pp. 1998-2004
    • Roy, D.1    Milot, G.2    Raymond, J.3
  • 3
    • 58249135792 scopus 로고    scopus 로고
    • Endovascular coil embolization of 435 small asymptomatic unruptured intracranial aneurysms: Procedural morbidity and patient outcome
    • Im SH, Han MH, Kwon OK, et al. Endovascular coil embolization of 435 small asymptomatic unruptured intracranial aneurysms: procedural morbidity and patient outcome. AJNR Am J Neuroradiol 2009;30:79-84
    • (2009) AJNR Am J Neuroradiol , vol.30 , pp. 79-84
    • Im, S.H.1    Han, M.H.2    Kwon, O.K.3
  • 4
    • 44449122873 scopus 로고    scopus 로고
    • Coiling of basilar tip aneurysms: Results in 154 consecutive patients with emphasis on recurrent haemorrhage and re-treatment during mid- and long-term follow-up
    • DOI 10.1136/jnnp.2007.127480
    • Peluso JP, van Rooij WJ, Sluzewski M, et al. Coiling of basilar tip aneurysms: results in 154 consecutive patients with emphasis on recurrent haemorrhage and re-treatment during mid- and long-term follow-up. J Neurol Neurosurg Psychiatry 2008;79:706-11. Epub 2007 Sep 10 (Pubitemid 351829446)
    • (2008) Journal of Neurology, Neurosurgery and Psychiatry , vol.79 , Issue.6 , pp. 706-711
    • Peluso, J.P.P.1    Van Rooij, W.J.2    Sluzewski, M.3    Beute, G.N.4
  • 5
    • 0037326691 scopus 로고    scopus 로고
    • Coiling of very large or giant cerebral aneurysms: Long-term clinical and serial angiographic results
    • Sluzewski M, Menovsky T, van Rooij WJ, et al. Coiling of very large or giant cerebral aneurysms: long-term clinical and serial angiographic results. AJNR Am J Neuroradiol 2003;24:257-62 (Pubitemid 36237179)
    • (2003) American Journal of Neuroradiology , vol.24 , Issue.2 , pp. 257-262
    • Sluzewski, M.1    Menovsky, T.2    Van Rooij, W.J.3    Wijnalda, D.4
  • 6
    • 0037407959 scopus 로고    scopus 로고
    • Neurologic complications of cerebral angiography: Prospective analysis of 2,899 procedures and review of the literature
    • DOI 10.1148/radiol.2272012071
    • Willinsky RA, Taylor SM, TerBrugge K, et al. Neurologic complications of cerebral angiography: prospective analysis of 2,899 procedures and review of the literature. Radiology 2003;227:522-28 (Pubitemid 36514772)
    • (2003) Radiology , vol.227 , Issue.2 , pp. 522-528
    • Willinsky, R.A.1    Taylor, S.M.2    TerBrugge, K.3    Farb, R.I.4    Tomlinson, G.5    Montanera, W.6
  • 7
    • 34249080891 scopus 로고    scopus 로고
    • Complications of diagnostic cerebral angiography: Evaluation of 19 826 consecutive patients
    • DOI 10.1148/radiol.2433060536
    • Kaufmann TJ, Huston J 3rd, Mandrekar JN, et al. Complications of diagnostic cerebral angiography: evaluation of 19,826 consecutive patients. Radiology 2007;243:812-19 (Pubitemid 46799436)
    • (2007) Radiology , vol.243 , Issue.3 , pp. 812-819
    • Kaufmann, T.J.1    Huston III, J.2    Mandrekar, J.N.3    Schleck, C.D.4    Thielen, K.R.5    Kallmes, D.F.6
  • 8
    • 70349931108 scopus 로고    scopus 로고
    • Evaluation of the occlusion status of coiled intracranial aneurysms with MR angiography at 3T: Is contrast enhancement necessary?
    • Sprengers ME, Schaafsma JD, van Rooij WJ, et al. Evaluation of the occlusion status of coiled intracranial aneurysms with MR angiography at 3T: is contrast enhancement necessary? AJNR Am J Neuroradiol 2009;30:1665-71
    • (2009) AJNR Am J Neuroradiol , vol.30 , pp. 1665-1671
    • Sprengers, M.E.1    Schaafsma, J.D.2    Van Rooij, W.J.3
  • 9
    • 77952366185 scopus 로고    scopus 로고
    • A prospective trial of 3T and 1.5T time-of-flight and contrast-enhanced MR angiography in the follow-up of coiled intracranial aneurysms
    • Kaufmann TJ, Huston J 3rd, Cloft HJ, et al. A prospective trial of 3T and 1.5T time-of-flight and contrast-enhanced MR angiography in the follow-up of coiled intracranial aneurysms. AJNR Am J Neuroradiol 2010;31:912-18
    • (2010) AJNR Am J Neuroradiol , vol.31 , pp. 912-918
    • Kaufmann, T.J.1    Huston III, J.2    Cloft, H.J.3
  • 10
    • 77955609475 scopus 로고    scopus 로고
    • Long-term prospective follow-up of intracranial aneurysms treated with endovascular coiling using contrast-enhanced MR angiography
    • Epub 2010 Mar 25
    • Shankar JJ, Lum C, Parikh N, et al. Long-term prospective follow-up of intracranial aneurysms treated with endovascular coiling using contrast-enhanced MR angiography. AJNR Am J Neuroradiol 2010;31:1211-15. Epub 2010 Mar 25
    • (2010) AJNR Am J Neuroradiol , vol.31 , pp. 1211-1215
    • Shankar, J.J.1    Lum, C.2    Parikh, N.3
  • 11
    • 34548182000 scopus 로고    scopus 로고
    • Noninvasive imaging of treated cerebral aneurysms, part II: CT angiographic follow-up of surgically clipped aneurysms
    • DOI 10.3174/ajnr.A0664
    • Wallace RC, Karis JP, Partovi S, et al. Noninvasive imaging of treated cerebral aneurysms. Part II. CT angiographic follow-up of surgically clipped aneurysms. AJNR Am J Neuroradiol 2007;28:1207-12 (Pubitemid 47309649)
    • (2007) American Journal of Neuroradiology , vol.28 , Issue.7 , pp. 1207-1212
    • Wallace, R.C.1    Karis, J.P.2    Partovi, S.3    Fiorella, D.4
  • 12
    • 36448975480 scopus 로고    scopus 로고
    • Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms
    • Richter G, Engelhorn T, Struffert T, et al. Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms.AJNR Am J Neuroradiol 2007;28:1902-08
    • (2007) AJNR Am J Neuroradiol , vol.28 , pp. 1902-1908
    • Richter, G.1    Engelhorn, T.2    Struffert, T.3
  • 13
    • 0033827919 scopus 로고    scopus 로고
    • Utility of CT angiography and MR angiography for the follow-up of experimental aneurysms treated with stents or Guglielmi detachable coils
    • Masaryk AM, Frayne R, Unal O, et al. Utility of CT angiography and MR angiography for the follow-up of experimental aneurysms treated with stents or Guglielmi detachable coils. AJNR Am J Neuroradiol 2000;21:1523-31
    • (2000) AJNR Am J Neuroradiol , vol.21 , pp. 1523-1531
    • Masaryk, A.M.1    Frayne, R.2    Unal, O.3
  • 14
    • 77955983087 scopus 로고    scopus 로고
    • Gated multidetector computed tomography: A technique to reduce intracranial aneurysm clip and coil artifacts
    • Epub 2010 May 21
    • Kovacs A, Flacke S, Tschampa H, et al. Gated multidetector computed tomography: a technique to reduce intracranial aneurysm clip and coil artifacts. Clin Neuroradiol 2010;20:99-107. Epub 2010 May 21
    • (2010) Clin Neuroradiol , vol.20 , pp. 99-107
    • Kovacs, A.1    Flacke, S.2    Tschampa, H.3
  • 15
    • 77952094212 scopus 로고    scopus 로고
    • Angiographic and artefact-free computed tomography imaging of experimental aneurysms embolised with hydrogel filaments
    • Epub 2009 Sep 16
    • McCoy MR, Cruise GM, Killer M. Angiographic and artefact-free computed tomography imaging of experimental aneurysms embolised with hydrogel filaments. Eur Radiol 2010;20:870-76. Epub 2009 Sep 16
    • (2010) Eur Radiol , vol.20 , pp. 870-876
    • McCoy, M.R.1    Cruise, G.M.2    Killer, M.3
  • 16
    • 0024588206 scopus 로고
    • Production of experimental aneurysms at a surgically created arterial bifurcation
    • Forrest MD, O'Reilly GV. Production of experimental aneurysms at a surgically created arterial bifurcation. AJNR Am J Neuroradiol 1989;10:400-02 (Pubitemid 19082634)
    • (1989) American Journal of Neuroradiology , vol.10 , Issue.2 , pp. 400-402
    • Forrest, M.D.1    O'Reilly, G.V.2
  • 17
    • 65949086787 scopus 로고    scopus 로고
    • Preparation, characterization, and evaluation of radiopaque hydrogel filaments for endovascular embolization
    • Constant MJ, Keeley EM, Cruise GM. Preparation, characterization, and evaluation of radiopaque hydrogel filaments for endovascular embolization. J Biomed Mater Res B Appl Biomater 2009;89:306-13
    • (2009) J Biomed Mater Res B Appl Biomater , vol.89 , pp. 306-313
    • Constant, M.J.1    Keeley, E.M.2    Cruise, G.M.3
  • 18
    • 34748892913 scopus 로고    scopus 로고
    • Hydrogel-coated and platinum coils for intracranial aneurysm embolization compared in three experimental models using computerized angiographic and histologic morphometry
    • DOI 10.1039/b707177a
    • Cruise GM, Shum JC, Plenk H Jr. Hydrogel-coated and platinum coils for intracranial aneurysm embolization compared in three experimental models using computerized angiographic and histologic morphometry. J Mater Chem 2007;17:3965-73 (Pubitemid 47482951)
    • (2007) Journal of Materials Chemistry , vol.17 , Issue.38 , pp. 3965-3973
    • Plenk Jr., H.1    Cruise, G.M.2    Shum, J.C.3
  • 19
    • 48449089919 scopus 로고    scopus 로고
    • Comparing the accuracy of digital subtraction angiography, CT angiography and MR angiography at estimating the volume of cerebral aneurysms
    • Hanley M, Zenzen WJ, Brown MD, et al. Comparing the accuracy of digital subtraction angiography, CT angiography and MR angiography at estimating the volume of cerebral aneurysms. Interv Neuroradiol 2008;14:173-77
    • (2008) Interv Neuroradiol , vol.14 , pp. 173-177
    • Hanley, M.1    Zenzen, W.J.2    Brown, M.D.3
  • 20
    • 0037931144 scopus 로고    scopus 로고
    • CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms: An experimental study
    • Piotin M, Gailloud P, Bidaut L, et al. CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms: an experimental study. Neuroradiology 2003;45: 404-09
    • (2003) Neuroradiology , vol.45 , pp. 404-409
    • Piotin, M.1    Gailloud, P.2    Bidaut, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.