Comparing the accuracy of digital subtraction angiography, CT angiography and MR angiography at estimating the volume of cerebral aneurysms

Author keywords

Cerebral angiography; Intracranial aneurysm; Volume measurement

Indexed keywords

ARTICLE; BRAIN ARTERY ANEURYSM; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTRAST ENHANCEMENT; CONTROLLED STUDY; DECISION MAKING; DIAGNOSTIC ACCURACY; DIAGNOSTIC ERROR; DIGITAL SUBTRACTION ANGIOGRAPHY; DISEASE MODEL; IMAGE ANALYSIS; IMAGE DISPLAY; INTERMETHOD COMPARISON; MAGNETIC RESONANCE ANGIOGRAPHY; MATHEMATICAL COMPUTING;

EID: 48449089919     PISSN: 11239344     EISSN: None     Source Type: Journal    
DOI: 10.1177/159101990801400208     Document Type: Article
Times cited : (11)

References (4)
  • 1
    • 0036094962 scopus 로고    scopus 로고
    • Evaluation of the stability of aneurysms after embolization using detachable coils: Correlation between stability of aneurysms and embolized volume of aneurysms
    • Tamatani S, Ito Y et Al: Evaluation of the stability of aneurysms after embolization using detachable coils: Correlation between stability of aneurysms and embolized volume of aneurysms. Am J Neuroradiol 23: 762-767, 2002.
    • (2002) Am J Neuroradiol , vol.23 , pp. 762-767
    • Tamatani, S.1    Ito, Y.2    et Al.3
  • 2
    • 2442640381 scopus 로고    scopus 로고
    • Relation between aneurysm volume, packing, and compaction in 145 cerebral aneurysms treated with coils
    • Sluzewski M, Willem JvR et Al: Relation between aneurysm volume, packing, and compaction in 145 cerebral aneurysms treated with coils. Radiology 231: 653-658, 2004.
    • (2004) Radiology , vol.231 , pp. 653-658
    • Sluzewski, M.1    Willem, J.R.2    et Al.3
  • 3
    • 0037931144 scopus 로고    scopus 로고
    • CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms. An experimental study
    • Piotin M, Gailloud P et Al: CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms. An experimental study. Neuroradiology 45: 404-409, 2003.
    • (2003) Neuroradiology , vol.45 , pp. 404-409
    • Piotin, M.1    Gailloud, P.2    et Al.3
  • 4
    • 33748063638 scopus 로고    scopus 로고
    • Ellipsoid approximation versus 3D rotational angiography in the volumetric assessment of intracranial aneurysms
    • Piotin M, Daghman B et Al: Ellipsoid approximation versus 3D rotational angiography in the volumetric assessment of intracranial aneurysms. Am J Neuroradiol 27(4): 839-842, 2006.
    • (2006) Am J Neuroradiol , vol.27 , Issue.4 , pp. 839-842