-
3
-
-
33645696556
-
Geant4 developments and applications
-
Allison J et al 2006 Geant4 developments and applications IEEE Trans. Nucl. Sci. 53 270-8
-
(2006)
IEEE Trans. Nucl. Sci.
, vol.53
, Issue.1
, pp. 270-278
-
-
Allison, J.1
-
5
-
-
62449092307
-
Performance evaluation of the Inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards
-
Bao Q, Newport D, Chen M, Stout D B and Chatziioannou A F 2009 Performance evaluation of the Inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards J. Nucl. Med. 50 401-8
-
(2009)
J. Nucl. Med.
, vol.50
, Issue.3
, pp. 401-408
-
-
Bao, Q.1
Newport, D.2
Chen, M.3
Stout, D.B.4
Chatziioannou, A.F.5
-
6
-
-
58149210333
-
PENELOPE-an algorithm for Monte Carlo simulation of the penetration and energy-loss of electrons and positrons in matter
-
Baro J, Sempau J, Fernandezvarea J M and Salvat F 1995 PENELOPE-an algorithm for Monte Carlo simulation of the penetration and energy-loss of electrons and positrons in matter Nucl. Instrum. Methods Phys. Res. B 100 31-46
-
(1995)
Nucl. Instrum. Methods Phys. Res.
, vol.100
, Issue.1
, pp. 31-46
-
-
Baro, J.1
Sempau, J.2
Fernandezvarea, J.M.3
Salvat, F.4
-
7
-
-
16344395296
-
Positron age-momentum-correlation (AMOC) measurements on organic liquids
-
Castellaz P, Siegle A and Stoll H 2002 Positron age-momentum-correlation (AMOC) measurements on organic liquids J. Nucl. Radiochem. Sci. 3 R1-7
-
(2002)
J. Nucl. Radiochem. Sci.
, vol.3
-
-
Castellaz, P.1
Siegle, A.2
Stoll, H.3
-
8
-
-
33645293502
-
Positron follow-up in liquid water: I. A new Monte Carlo track-structure code
-
Champion C and Loirec C L 2006 Positron follow-up in liquid water: I. A new Monte Carlo track-structure code Phys. Med. Biol. 51 1707-23
-
(2006)
Phys. Med. Biol.
, vol.51
, Issue.7
, pp. 1707-1723
-
-
Champion, C.1
Loirec, C.L.2
-
9
-
-
35848931687
-
Positron follow-up in liquid water: II. Spatial and energetic study for the most important radioisotopes used in PET
-
DOI 10.1088/0031-9155/52/22/004, PII S0031915507472761
-
Champion C and Loirec C L 2007 Positron follow-up in liquid water: II. Spatial and energetic study for the most important radioisotopes used in PET Phys. Med. Biol. 52 6605-25 (Pubitemid 350058950)
-
(2007)
Physics in Medicine and Biology
, vol.52
, Issue.22
, pp. 6605-6625
-
-
Champion, C.1
Le Loirec, C.2
-
11
-
-
0016698304
-
Positron ranges obtained from biomedically important positron-emitting radionuclides
-
Cho Z H, Chan J K, Ericksson L, Singh M, Graham S, MacDonald N S and Yano Y 1975 Positron ranges obtained from biomedically important positron-emitting radionuclides J. Nucl. Med. 16 1174-6
-
(1975)
J. Nucl. Med.
, vol.16
, Issue.12
, pp. 1174-1176
-
-
Cho, Z.H.1
Chan, J.K.2
Ericksson, L.3
Singh, M.4
Graham, S.5
MacDonald, N.S.6
Yano, Y.7
-
12
-
-
51249195171
-
Study of positronium in water and ice from 22 to-144 °c by annihilation quanta measurements
-
Colombino P, Fiscella B and Trossi L 1965 Study of positronium in water and ice from 22 to-144 °C by annihilation quanta measurements Nuovo Cimento 38 707-23
-
(1965)
Nuovo Cimento
, vol.38
, Issue.2
, pp. 707-723
-
-
Colombino, P.1
Fiscella, B.2
Trossi, L.3
-
13
-
-
84939036393
-
Mathematical removal of positron range blurring in high resolution tomography
-
Derenzo S E 1986 Mathematical removal of positron range blurring in high resolution tomography IEEE Trans. Nucl. Sci. 33 565-9
-
(1986)
IEEE Trans. Nucl. Sci.
, vol.33
, Issue.1
, pp. 565-569
-
-
Derenzo, S.E.1
-
14
-
-
77950951879
-
Image-quality assessment for several positron emitters using the NEMA NU 4-2008 standards in the Siemens Inveon small-animal PET scanner
-
Disselhorst J A, Brom M, Laverman P, Slump C H, Boerman O C, Oyen W J G, Gotthardt M and Visser E P 2010 Image-quality assessment for several positron emitters using the NEMA NU 4-2008 standards in the Siemens Inveon small-animal PET scanner J. Nucl. Med. 51 610-7
-
(2010)
J. Nucl. Med.
, vol.51
, Issue.4
, pp. 610-617
-
-
Disselhorst, J.A.1
Brom, M.2
Laverman, P.3
Slump, C.H.4
Boerman, O.C.5
Oyen, W.J.G.6
Gotthardt, M.7
Visser, E.P.8
-
18
-
-
5744251917
-
GATE: A simulation toolkit for PET and SPECT
-
Jan S et al 2004 GATE: a simulation toolkit for PET and SPECT Phys. Med. Biol. 49 4543
-
(2004)
Phys. Med. Biol.
, vol.49
, Issue.19
, pp. 4543
-
-
Jan, S.1
-
19
-
-
33846605907
-
Monte Carlo simulation of the microPET FOCUS system for small rodents imaging applications
-
DOI 10.1109/NSSMIC.2005.1596637, 1596637, 2005 IEEE Nuclear Science Symposium Conference Record -Nuclear Science Symposium and Medical Imaging Conference
-
Jan S et al 2005 Monte Carlo simulation of the microPET FOCUS system for small rodents imaging applications IEEE Nuclear Science Symp. Conf. Record vol 3 pp 1653-7 (Pubitemid 46172061)
-
(2005)
IEEE Nuclear Science Symposium Conference Record
, vol.3
, pp. 1653-1657
-
-
Jan, S.1
Desbree, A.2
Pain, F.3
Guez, D.4
Comtat, C.5
Gurden, H.6
Kerhoas, S.7
Laniece, P.8
Lefebvre, F.9
Mastrippolito, R.10
Trebossen, R.11
-
20
-
-
0002216759
-
Range-energy relations for electrons and the determination of beta-ray end-point energies by absorption
-
Katz L and Penfold A S 1952 Range-energy relations for electrons and the determination of beta-ray end-point energies by absorption Rev. Mod. Phys. 24 28-44
-
(1952)
Rev. Mod. Phys.
, vol.24
, Issue.1
, pp. 28-44
-
-
Katz, L.1
Penfold, A.S.2
-
21
-
-
0034104708
-
Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
-
DOI 10.1118/1.598917
-
Kawrakow I 2000 Accurate condensed history Monte Carlo simulation of electron transport: I. EGSnrc, the new EGS4 version Med. Phys. 27 485-98 (Pubitemid 30171797)
-
(2000)
Medical Physics
, vol.27
, Issue.3
, pp. 485-498
-
-
Kawrakow, I.1
-
23
-
-
34547751970
-
Validation of PET-SORTEO Monte Carlo simulations for the geometries of the MicroPET R4 and Focus 220 PET scanners
-
DOI 10.1088/0031-9155/52/16/009, PII S003191550745802X, 009
-
Lartizien C, Kuntner C, Goertzen A L, Evans A C and Reilhac A 2007 Validation of PET-SORTEO Monte Carlo simulations for the geometries of the MicroPET R4 and Focus 220 PET scanners Phys. Med. Biol. 52 4845-62 (Pubitemid 47232291)
-
(2007)
Physics in Medicine and Biology
, vol.52
, Issue.16
, pp. 4845-4862
-
-
Lartizien, C.1
Kuntner, C.2
Goertzen, A.L.3
Evans, A.C.4
Reilhac, A.5
-
24
-
-
67649172230
-
An investigation of partial volume effect and partial volume correction in small animal positron emission tomography (PET) of the rat brain
-
Lehnert W, Gregoire M-C, Xiao H and Meikle S R 2008 An investigation of partial volume effect and partial volume correction in small animal positron emission tomography (PET) of the rat brain IEEE Nuclear Science Symp. Conf. Record pp 5219-24
-
(2008)
IEEE Nuclear Science Symp. Conf. Record
, pp. 5219-5224
-
-
Lehnert, W.1
Gregoire, M.-C.2
Xiao, H.3
Meikle, S.R.4
-
25
-
-
0033059817
-
Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution
-
DOI 10.1088/0031-9155/44/3/019, PII S0031915599950285
-
Levin C S and Hoffman E J 1999 Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution Phys. Med. Biol. 44 781-99 (Pubitemid 29133069)
-
(1999)
Physics in Medicine and Biology
, vol.44
, Issue.3
, pp. 781-799
-
-
Levin, C.S.1
Hoffman, E.J.2
-
28
-
-
0026927291
-
Annihilation density distribution calculations for medically important positron emitters
-
Palmer M R and Brownell G L 1992 Annihilation density distribution calculations for medically important positron emitters IEEE Trans. Med. Imaging 11 373-8
-
(1992)
IEEE Trans. Med. Imaging
, vol.11
, Issue.3
, pp. 373-378
-
-
Palmer, M.R.1
Brownell, G.L.2
-
29
-
-
29144503212
-
Modeling and simulation of positron range effects for high resolution PET imaging
-
DOI 10.1109/TNS.2005.858264
-
Palmer M R, Xuping Z and Parker J A 2005 Modeling and simulation of positron range effects for high resolution PET imaging IEEE Trans. Nucl. Sci. 52 1391-5 (Pubitemid 41810426)
-
(2005)
IEEE Transactions on Nuclear Science
, vol.52
, Issue.5
, pp. 1391-1395
-
-
Palmer, M.R.1
Zhu, X.2
Parker, J.A.3
-
32
-
-
2342462955
-
PET-SORTEO: A Monte Carlo-based simulator with high count rate capabilities
-
Reilhac A, Lartizien C, Costes N, Sans S, Comtat C, Gunn R N and Evans A C 2004 PET-SORTEO: a Monte Carlo-based simulator with high count rate capabilities IEEE Trans. Nucl. Sci. 51 46-52
-
(2004)
IEEE Trans. Nucl. Sci.
, vol.51
, Issue.1
, pp. 46-52
-
-
Reilhac, A.1
Lartizien, C.2
Costes, N.3
Sans, S.4
Comtat, C.5
Gunn, R.N.6
Evans, A.C.7
-
33
-
-
0010052114
-
On lifting the inherent limitations of positron emission tomography by using magnetic fields (MagPET)
-
Rickey D W, Gordon R and Huda W 1992 On lifting the inherent limitations of positron emission tomography by using magnetic fields (MagPET) Automedica 14 355-69
-
(1992)
Automedica
, vol.14
, pp. 355-369
-
-
Rickey, D.W.1
Gordon, R.2
Huda, W.3
-
34
-
-
0002678058
-
Generalized semiempirical equations for the extrapolated range of electrons
-
Tabata T, Ito R and Okabe S 1972 Generalized semiempirical equations for the extrapolated range of electrons Nucl. Instrum. Methods 103 85-91
-
(1972)
Nucl. Instrum. Methods
, vol.103
, Issue.1
, pp. 85-91
-
-
Tabata, T.1
Ito, R.2
Okabe, S.3
-
35
-
-
17844363989
-
Performance evaluation of the microPET focus: A third-generation microPET scanner dedicated to animal imaging
-
Tai Y-C, Ruangma A, Rowland D, Siegel S, Newport D F, Chow P L and Laforest R 2005 Performance evaluation of the microPET Focus: a third-generation microPET scanner dedicated to animal imaging J. Nucl. Med. 46 455-63 (Pubitemid 43093155)
-
(2005)
Journal of Nuclear Medicine
, vol.46
, Issue.3
, pp. 455-463
-
-
Tai, Y.-C.1
Ruangma, A.2
Rowland, D.3
Siegel, S.4
Newport, D.F.5
Chow, P.L.6
Laforest, R.7
-
36
-
-
67349157153
-
Effect of the positron range on the spatial resolution of a new generation pre-clinical PET using fluorine-18, gallium-68, zirconium-89 and iodine-124
-
van Dalen J A, Visser E P, Laverman P, Vogel W V, Oyen W J G, Corstens F H M and Boerman O C 2007 Effect of the positron range on the spatial resolution of a new generation pre-clinical PET using fluorine-18, gallium-68, zirconium-89 and iodine-124 Eur. J. Nucl. Med. Mol. Imaging 34 S228-S
-
(2007)
Eur. J. Nucl. Med. Mol. Imaging
, vol.34
-
-
Van Dalen, J.A.1
Visser, E.P.2
Laverman, P.3
Vogel, W.V.4
Oyen, W.J.G.5
Corstens, F.H.M.6
Boerman, O.C.7
-
37
-
-
0003087344
-
Various techniques used in connection with random digits. Monte Carlo methods
-
von Neumann J 1951 Various techniques used in connection with random digits. Monte Carlo methods Nat. Bur. Stand. 12 36-8
-
(1951)
Nat. Bur. Stand.
, vol.12
, pp. 36-38
-
-
Von Neumann, J.1
|