메뉴 건너뛰기




Volumn 16, Issue 1, 2011, Pages

Broadband optical ultrasound sensor with a unique open-cavity structure

Author keywords

hydrophone; optical ultrasound sensor; photoacoustic imaging; ultrasound imaging

Indexed keywords

CARDIO-VASCULAR DISEASE; FABRICATION COST; HIGH FREQUENCY HF; HIGH FREQUENCY ULTRASOUNDS; HIGH RESOLUTION; HIGH SENSITIVITY; INTRAVASCULAR IMAGING; OPTICAL CAVITIES; OPTICAL TECHNIQUE; OPTICAL ULTRASOUND SENSOR; PHOTOACOUSTIC IMAGING; PIEZOELECTRIC TECHNOLOGY; POLYVINYLIDENE FLUORIDES; SIGNAL FIDELITY; TECHNICAL LIMITATIONS; TOTAL INTERNAL REFLECTIONS; TWO MIRRORS; ULTRASOUND IMAGING; ULTRASOUND SENSORS; WIDE BANDWIDTH;

EID: 79955977211     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.3528014     Document Type: Article
Times cited : (19)

References (23)
  • 1
    • 0024394352 scopus 로고
    • Are hydrophones of diameter 0.5 mm small enough to characterise diagnostic ultrasound equipment?
    • R. A. Smith, Are hydrophones of diameter 0.5 mm small enough to characterise diagnostic ultrasound equipment Physics Med. Biol. 34, 1593-1607 (1989). 10.1088/0031-9155/34/11/007 (Pubitemid 19265766)
    • (1989) Physics in Medicine and Biology , vol.34 , Issue.11 , pp. 1593-1607
    • Smith, R.A.1
  • 2
    • 0038078492 scopus 로고    scopus 로고
    • Microfabrication of thick and bulk PZT materials for piezoelectric actuator
    • 10.1117/12.476088
    • S. H. Lee, R. Maeda, and M. Esashi, Microfabrication of thick and bulk PZT materials for piezoelectric actuator., Proc. SPIE 4936, 365-372 (2002). 10.1117/12.476088
    • (2002) Proc. SPIE , vol.4936 , pp. 365-372
    • Lee, S.H.1    Maeda, R.2    Esashi, M.3
  • 3
    • 17644376187 scopus 로고    scopus 로고
    • Optoacoustic imaging using thin polymer ́talon
    • DOI 10.1063/1.1896085, 134102
    • S. Ashkenazi, Y. Hou, T. Buma, and M. Odonnell, Optoacoustic imaging using thin polymer etalon., Appl. Phys. Lett. 86, 134102 (2005). 10.1063/1.1896085 (Pubitemid 40564936)
    • (2005) Applied Physics Letters , vol.86 , Issue.13 , pp. 1-3
    • Ashkenazi, S.1    Hou, Y.2    Buma, T.3    O'Donnell, M.4
  • 5
    • 34948840958 scopus 로고    scopus 로고
    • Broadband PVDF membrane hydrophone for comparisons of hydrophone calibration methods up to 140 MHz
    • DOI 10.1109/TUFFC.2007.462
    • V. Wilkens and W. Molkenstruck, Broadband PVDF membrane hydrophone for comparisons of hydrophone calibration methods up to 140 MHz., IEEE Trans. Ultrason. Ferroelectr. Freq. Control 54, 1784-1791 (2007). 10.1109/TUFFC.2007. 462 (Pubitemid 47525310)
    • (2007) IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control , vol.54 , Issue.9 , pp. 1784-1791
    • Wilkens, V.1    Molkenstruck, W.2
  • 6
    • 12144266937 scopus 로고    scopus 로고
    • Ultra high sensitivity, wideband Fabry Perot ultrasound sensors as an alternative to piezoelectric PVDF transducers for biomedical photoacoustic detection
    • DOI 10.1117/12.531160, 32, Photons Plus Ultrasound: Imaging and Sensing
    • E. Z. Y. Zhang and P. C. Beard, Ultrahigh-sensitivity wideband Fabry-Perot ultrasound sensors as an alternative to piezoelectric PVDF transducers for biomedical photoacoustic detection., Proc. SPIE 5320, 222-229 (2004). 10.1117/12.531160 (Pubitemid 40108964)
    • (2004) Progress in Biomedical Optics and Imaging - Proceedings of SPIE , vol.5 , Issue.9 , pp. 222-229
    • Zhang, E.Z.1    Beard, P.2
  • 7
    • 0037336435 scopus 로고    scopus 로고
    • Characterization of an optical multilayer hydrophone with constant frequency response in the range from 1 to 75 MHz
    • DOI 10.1121/1.1553457
    • V. Wilkens, Characterization of an optical multilayer hydrophone with constant frequency response in the range from 1 to 75 MHz., J. Acoust. Soc. Am. 113, 1431-1438 (2003). 10.1121/1.1553457 (Pubitemid 36297947)
    • (2003) Journal of the Acoustical Society of America , vol.113 , Issue.3 , pp. 1431-1438
    • Wilkens, V.1
  • 8
    • 41449089257 scopus 로고    scopus 로고
    • Backward-mode multiwavelength photoacoustic scanner using a planar Fabry-Perot polymer film ultrasound sensor for high-resolution three-dimensional imaging of biological tissues
    • DOI 10.1364/AO.47.000561
    • E. Zhang, J. Laufer, and P. Beard, Backward-mode multiwavelength photoacoustic scanner using a planar Fabry-Perot polymer film ultrasound sensor for high-resolution three-dimensional imaging of biological tissues., Appl. Opt. 47, 561-577 (2008). 10.1364/AO.47.000561 (Pubitemid 351456537)
    • (2008) Applied Optics , vol.47 , Issue.4 , pp. 561-577
    • Zhang, E.1    Laufer, J.2    Beard, P.3
  • 9
    • 33747206151 scopus 로고    scopus 로고
    • Broadband ultrasound field mapping system using a wavelength tuned, optically scanned focused laser beam to address a Fabry Perot polymer film sensor
    • 10.1109/TUFFC.2006.1665081
    • E. Zhang and P. Beard, Broadband ultrasound field mapping system using a wavelength tuned, optically scanned focused laser beam to address a Fabry Perot polymer film sensor., IEEE Trans. Ultrason. Ferroelectr. Freq. Control 53, 1330-1338 (2006). 10.1109/TUFFC.2006.1665081
    • (2006) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.53 , pp. 1330-1338
    • Zhang, E.1    Beard, P.2
  • 10
    • 0031118065 scopus 로고    scopus 로고
    • Miniature optical fibre ultrasonic hydrophone using a Fabry-Perot polymer film interferometer
    • P. C. Beard and T. N. Mills, Miniature optical fibre ultrasonic hydrophone using a Fabry-Perot polymer film interferometer., Electron. Lett. 33, 801-803 (1997). 10.1049/el:19970545 (Pubitemid 127598056)
    • (1997) Electronics Letters , vol.33 , Issue.9 , pp. 801-803
    • Beard, P.C.1    Mills, T.N.2
  • 11
    • 0002717815 scopus 로고
    • Optical detection of ultrasound at a distance using a confocal Fabry-Perot interferometer
    • 10.1063/1.96411
    • J. P. Monchalin, Optical detection of ultrasound at a distance using a confocal Fabry-Perot interferometer., Appl. Phys. Lett. 47, 14-16 (1985). 10.1063/1.96411
    • (1985) Appl. Phys. Lett. , vol.47 , pp. 14-16
    • Monchalin, J.P.1
  • 12
    • 0036992339 scopus 로고    scopus 로고
    • Characterization of an optical multilayer hydrophone for use as broadband ultrasound reference receiver-comparison with PVDF membrane hydrophones
    • in, Vol.
    • V. Wilkens, Characterization of an optical multilayer hydrophone for use as broadband ultrasound reference receiver-comparison with PVDF membrane hydrophones., in Proc. IEEE -Ultrasonics Symp., Vol. 771, pp. 773-776 (2002).
    • (2002) Proc. IEEE -Ultrasonics Symp. , vol.771 , pp. 773-776
    • Wilkens, V.1
  • 13
    • 0033310086 scopus 로고    scopus 로고
    • Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection
    • DOI 10.1109/58.808883
    • P. C. Beard, F. Perennes, and T. N. Mills, Transduction mechanisms of the Fabry-Perot polymer -film sensing concept for wideband ultrasound detection., IEEE Trans. Ultrason Ferroelectr. Freq. Control 46, 1575-1582 (1999). 10.1109/58.808883 (Pubitemid 30536499)
    • (1999) IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control , vol.46 , Issue.6 , pp. 1575-1582
    • Beard, P.C.1
  • 14
    • 33847707398 scopus 로고    scopus 로고
    • The frequency-dependent directivity of a planar Fabry-Perot polymer film ultrasound sensor
    • DOI 10.1109/TUFFC.2007.253
    • B. T. Cox and P. C. Beard, The frequency-dependent directivity of a planar Fabry-Perot polymer film ultrasound sensor., IEEE Trans. Ultrason Ferroelectr. Freq. Control 54, 394-404 (2007). 10.1109/TUFFC.2007.253 (Pubitemid 46380024)
    • (2007) IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control , vol.54 , Issue.2 , pp. 394-404
    • Cox, B.T.1    Beard, P.C.2
  • 15
    • 0032265802 scopus 로고    scopus 로고
    • Comparison of a miniature, ultrasonic, optical fibre hydrophone with PVDF hydrophone technology
    • in, Vol.
    • P. C. Beard, A. Hurrell, E. Van Den Elzen, and T. N. Mills, Comparison of a miniature, ultrasonic, optical fibre hydrophone with PVDF hydrophone technology., in Proc. IEEE Ultrasonics Symp., Vol. 1882, pp. 1881-1884 (1998).
    • (1998) Proc. IEEE Ultrasonics Symp. , vol.1882 , pp. 1881-1884
    • Beard, P.C.1    Hurrell, A.2    Van Den Elzen, E.3    Mills, T.N.4
  • 16
    • 0036628594 scopus 로고    scopus 로고
    • Frequency response of fiber-optic multilayer hydrophones: Experimental investigation and finite element simulation
    • 10.1109/TUFFC.2002.1020164
    • W. Weise, V. Wilkens, and C. Koch, Frequency response of fiber-optic multilayer hydrophones: experimental investigation and finite element simulation., IEEE Trans. Ultrason Ferroelectr. Freq. Contol. 49, 937-945 (2002). 10.1109/TUFFC.2002.1020164
    • (2002) IEEE Trans. Ultrason Ferroelectr. Freq. Contol. , vol.49 , pp. 937-945
    • Weise, W.1    Wilkens, V.2    Koch, C.3
  • 17
    • 4644324503 scopus 로고    scopus 로고
    • Yield strength of thin-film parylene-C
    • 10.1007/BF02637112
    • C. Y. Shih, T. A. Harder, and Y. C. Tai, Yield strength of thin-film parylene-C., Microsyst. Technol. 10, 407-411 (2004). 10.1007/BF02637112
    • (2004) Microsyst. Technol. , vol.10 , pp. 407-411
    • Shih, C.Y.1    Harder, T.A.2    Tai, Y.C.3
  • 18
    • 49149097631 scopus 로고    scopus 로고
    • Sensitive molecular binding assay using aphotonic crystal structure in total internalreflection
    • 10.1364/OE.16.011741
    • Y. Guo, C. Divin, A. Myc, F. L. Terry Jr., J. R. Baker Jr., T. B. Norris, and J. Y. Ye, Sensitive molecular binding assay using aphotonic crystal structure in total internalreflection., Opt. Express 16, 11741-11749 (2008). 10.1364/OE.16.011741
    • (2008) Opt. Express , vol.16 , pp. 11741-11749
    • Guo, Y.1    Divin, C.2    Myc, A.3    Terry, F.L.4    Baker Jr., J.R.5    Norris, T.B.6    Ye, J.Y.7
  • 19
    • 49349098992 scopus 로고    scopus 로고
    • Enhancing fluorescence detection with a photonic crystal structure in a total-internal-reflection configuration
    • 10.1364/OL.33.001729
    • J. Y. Ye and M. Ishikawa, Enhancing fluorescence detection with a photonic crystal structure in a total-internal-reflection configuration., Opt. Lett. 33, 1729-1731 (2008). 10.1364/OL.33.001729
    • (2008) Opt. Lett. , vol.33 , pp. 1729-1731
    • Ye, J.Y.1    Ishikawa, M.2
  • 20
    • 23244458393 scopus 로고    scopus 로고
    • Fabry Perot polymer film fibre-optic hydrophones and arrays for ultrasound field characterisation
    • 10.1088/1742-6596/1/1/009
    • B. T. Cox, E. Z. Zhang, J. G. Laufer, and P. C. Beard, Fabry Perot polymer film fibre-optic hydrophones and arrays for ultrasound field characterisation., J. Phys. Conf. Ser. 1, 32-37 (2004). 10.1088/1742-6596/1/1/ 009
    • (2004) J. Phys. Conf. Ser. , vol.1 , pp. 32-37
    • Cox, B.T.1    Zhang, E.Z.2    Laufer, J.G.3    Beard, P.C.4
  • 21
    • 0037159282 scopus 로고    scopus 로고
    • Coronary plaque classification with intravascular ultrasound radiofrequency data analysis
    • DOI 10.1161/01.CIR.0000035654.18341.5E
    • A. Nair, B. D. Kuban, E. M. Tuzcu, P. Schoenhagen, S. E. Nissen, and D. G. Vince, Coronary plaque classification with intravascular ultrasound radiofrequency data analysis., Circulation 106, 2200-2206 (2002). 10.1161/01.CIR.0000035654.18341.5E (Pubitemid 35222213)
    • (2002) Circulation , vol.106 , Issue.17 , pp. 2200-2206
    • Nair, A.1    Kuban, B.D.2    Tuzcu, E.M.3    Schoenhagen, P.4    Nissen, S.E.5    Vince, D.G.6
  • 23
    • 23244468110 scopus 로고    scopus 로고
    • Atherosclerotic plaque characterization with optoacoustic imaging
    • DOI 10.1117/12.591593, 35, Photons Plus Ultrasound: Imaging and Sensing 2005 - The sixth Conference on Biomedical Thermoacoustics, Optoacoustics, and Acousto-Optics
    • P. M. Henrichs, J. W. Meador, J. M. Fuqua, and A. A. Oraevsky, Atherosclerotic plaque characterization with optoacoustic imaging., Proc. SPIE 5697, 217-223 (2005) 10.1117/12.591593. (Pubitemid 41091216)
    • (2005) Progress in Biomedical Optics and Imaging - Proceedings of SPIE , vol.5697 , pp. 217-223
    • Henrichs, P.M.1    Meador, J.W.2    Fuqua, J.M.3    Oraevsky, A.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.