메뉴 건너뛰기




Volumn 26, Issue 4, 2011, Pages 665.e17-665.e20

Fatigue Fracture of a Short Stem Hip Replacement: A Failure Analysis With Electron Microscopy and Review of the Literature

Author keywords

Cementless hip; Fatigue fracture; Short stemmed prosthesis

Indexed keywords

METAL; NONSTEROID ANTIINFLAMMATORY AGENT;

EID: 79955972366     PISSN: 08835403     EISSN: 15328406     Source Type: Journal    
DOI: 10.1016/j.arth.2010.05.021     Document Type: Article
Times cited : (25)

References (11)
  • 1
    • 0019811096 scopus 로고
    • Fracture of the femoral component after total hip replacement. An analysis of fifty-eight cases
    • Chao E.Y.S., Coventry M.B. Fracture of the femoral component after total hip replacement. An analysis of fifty-eight cases. J Bone Joint Surg 1981, 63-A:1078.
    • (1981) J Bone Joint Surg , pp. 1078
    • Chao, E.Y.S.1    Coventry, M.B.2
  • 2
    • 29244474600 scopus 로고    scopus 로고
    • Late fatigue fracture of a modern cemented [corrected] cobalt chrome stem for total hip arthroplasty: a report of 10 cases
    • Della Valle A., Becksac B., Anderson J., et al. Late fatigue fracture of a modern cemented [corrected] cobalt chrome stem for total hip arthroplasty: a report of 10 cases. J Arthroplasty 2005, 20:1084.
    • (2005) J Arthroplasty , vol.20 , pp. 1084
    • Della Valle, A.1    Becksac, B.2    Anderson, J.3
  • 3
    • 3343026092 scopus 로고    scopus 로고
    • Fatigue failure of the femoral component of a cementless total hip arthroplasty
    • Morgan-Hough C.V., Tavakkolizadeh A., Purkayastha S. Fatigue failure of the femoral component of a cementless total hip arthroplasty. J Arthroplasty 2004, 19:658.
    • (2004) J Arthroplasty , vol.19 , pp. 658
    • Morgan-Hough, C.V.1    Tavakkolizadeh, A.2    Purkayastha, S.3
  • 4
    • 0028343874 scopus 로고
    • Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems. A failure analysis of two implants
    • Gilbert J.L., Buckley C.A., Jacobs J.J., et al. Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems. A failure analysis of two implants. J Bone Joint Surg 1994, 76A:110-115.
    • (1994) J Bone Joint Surg , vol.76 A , pp. 110-115
    • Gilbert, J.L.1    Buckley, C.A.2    Jacobs, J.J.3
  • 6
    • 0036903335 scopus 로고    scopus 로고
    • Stem fracture of the Cementless Spongy Metal Lübeck Hip Prosthesis
    • Kishida Y., Sugano N., Ohzono K., et al. Stem fracture of the Cementless Spongy Metal Lübeck Hip Prosthesis. J Arthroplasty 2002, 17:1021.
    • (2002) J Arthroplasty , vol.17 , pp. 1021
    • Kishida, Y.1    Sugano, N.2    Ohzono, K.3
  • 7
    • 0018838142 scopus 로고
    • Three dimensional stress analysis of the femoral stem of a total hip prosthesis
    • Hampton S.J., Andiacchi T.P., Galante J.O. Three dimensional stress analysis of the femoral stem of a total hip prosthesis. J Biomech 1980, 13:443.
    • (1980) J Biomech , vol.13 , pp. 443
    • Hampton, S.J.1    Andiacchi, T.P.2    Galante, J.O.3
  • 8
    • 0034110636 scopus 로고    scopus 로고
    • Schenkelhalsprothese Typ Cut-Eine funktionell-morphologische Analyse
    • Koebke J., Xepulias P., Thomas W. Schenkelhalsprothese Typ Cut-Eine funktionell-morphologische Analyse. Biomed Tech 2000, 45:135.
    • (2000) Biomed Tech , vol.45 , pp. 135
    • Koebke, J.1    Xepulias, P.2    Thomas, W.3
  • 9
    • 40849100229 scopus 로고    scopus 로고
    • Maintenance of bone mineral density after implantation of a femoral neck hip prosthesis
    • Decking R., Rokahr C., Zurstegge M., et al. Maintenance of bone mineral density after implantation of a femoral neck hip prosthesis. BMC Musculoskelet Disord 2008, 9:17.
    • (2008) BMC Musculoskelet Disord , vol.9 , pp. 17
    • Decking, R.1    Rokahr, C.2    Zurstegge, M.3
  • 10
    • 67449089840 scopus 로고    scopus 로고
    • Eight-year results of the femoral neck prosthesis ESKA-CUT
    • Ishaque B.A., Donle E., Gils J., et al. Eight-year results of the femoral neck prosthesis ESKA-CUT. Z Orthop Unfallchir 2009, 147:158.
    • (2009) Z Orthop Unfallchir , vol.147 , pp. 158
    • Ishaque, B.A.1    Donle, E.2    Gils, J.3
  • 11
    • 79955946047 scopus 로고    scopus 로고
    • Primary stability of short-stem designs compared to conventional stems in total hip arthroplasty
    • Thomsen M., Lee C., Bitsch R., et al. Primary stability of short-stem designs compared to conventional stems in total hip arthroplasty. J Bone Joint Surg Br 2006, 88(Suppl):54.
    • (2006) J Bone Joint Surg Br , vol.88 , Issue.SUPPL. , pp. 54
    • Thomsen, M.1    Lee, C.2    Bitsch, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.