메뉴 건너뛰기




Volumn 60, Issue 6, 2011, Pages 2080-2087

Wet-gas flow modeling for the straight section of throat-extended Venturi meter

Author keywords

Fitting error; flow modeling; separated flow; Venturi meter; wet gas metering

Indexed keywords

FITTING ERROR; FLOW MODELING; SEPARATED FLOW; VENTURI METERS; WET-GAS METERING;

EID: 79955962903     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIM.2011.2117190     Document Type: Article
Times cited : (31)

References (23)
  • 1
    • 0041821714 scopus 로고    scopus 로고
    • On fluctuation of the dynamic differential pressure signal of Venturi meter for wet gas metering
    • DOI 10.1016/S0955-5986(03)00027-X
    • L. J. Xu, J. Xu, F. Dong, and T. Zhang, "On fluctuation of the dynamic differential pressure signal of Venturi meter for wet gas metering," Flow Meas. Instrum., vol. 14, no. 4/5, pp. 211-217, Aug.-Oct. 2003. (Pubitemid 37036272)
    • (2003) Flow Measurement and Instrumentation , vol.14 , Issue.4-5 , pp. 211-217
    • Xu, L.1    Xu, J.2    Dong, F.3    Zhang, T.4
  • 2
    • 51349107764 scopus 로고    scopus 로고
    • Wet gas metering using a Venturi-meter and neural networks
    • Victoria, BC, Canada, May 12-15
    • L. J. Xu, H. Li, S. L. Tang, C. Tan, and B. Hu, "Wet gas metering using a Venturi-meter and neural networks," in Proc. IEEE Int. Instrum. Meas. Technol. Conf., Victoria, BC, Canada, May 12-15, 2008, pp. 761-764.
    • (2008) Proc. IEEE Int. Instrum. Meas. Technol. Conf. , pp. 761-764
    • Xu, L.J.1    Li, H.2    Tang, S.L.3    Tan, C.4    Hu, B.5
  • 3
    • 53349091916 scopus 로고    scopus 로고
    • A dimensional analysis of two phase flow through a horizontally installed Venturi flow meter
    • Dec.
    • R. Steven, "A dimensional analysis of two phase flow through a horizontally installed Venturi flow meter," Flow Meas. Instrum., vol. 19, no. 6, pp. 342-349, Dec. 2008.
    • (2008) Flow Meas. Instrum. , vol.19 , Issue.6 , pp. 342-349
    • Steven, R.1
  • 4
    • 0035742047 scopus 로고    scopus 로고
    • Wet gas metering with a horizontally mounted Venturi meter
    • R. Steven, "Wet gas metering with a horizontally mounted Venturi meter," Flow Meas. Instrum., vol. 12, no. 5/6, pp. 361-372, 2002.
    • (2002) Flow Meas. Instrum. , vol.12 , Issue.5-6 , pp. 361-372
    • Steven, R.1
  • 5
    • 6444220077 scopus 로고    scopus 로고
    • Simple installation for measurement of two-phase gas-liquid flow by means of conventional single-phase flowmeters
    • DOI 10.1016/j.flowmeasinst.2004.06.001, PII S0955598604000378
    • M. Turkowski, "Simple installation for measurement of two-phase gasliquid flow by means of conventional single-phase flowmeters," Flow Meas. Instrum., vol. 15, no. 5/6, pp. 295-299, Oct.-Dec. 2004. (Pubitemid 39407933)
    • (2004) Flow Measurement and Instrumentation , vol.15 , Issue.5-6 , pp. 295-299
    • Turkowski, M.1
  • 6
    • 30544432108 scopus 로고    scopus 로고
    • Study on the metering characteristics of a slotted orifice for wet gas flow
    • Apr.
    • Y. F. Geng, J. W. Zheng, and T. M. Shi, "Study on the metering characteristics of a slotted orifice for wet gas flow," Flow Meas. Instrum., vol. 17, no. 2, pp. 123-128, Apr. 2006.
    • (2006) Flow Meas. Instrum. , vol.17 , Issue.2 , pp. 123-128
    • Geng, Y.F.1    Zheng, J.W.2    Shi, T.M.3
  • 7
    • 68049101191 scopus 로고    scopus 로고
    • Orifice plate meter wet gas flow performance
    • Aug.-Oct.
    • R. Steven and A. Hall, "Orifice plate meter wet gas flow performance," Flow Meas. Instrum., vol. 20, no. 4/5, pp. 141-151, Aug.-Oct. 2009.
    • (2009) Flow Meas. Instrum. , vol.20 , Issue.4-5 , pp. 141-151
    • Steven, R.1    Hall, A.2
  • 8
    • 33847187721 scopus 로고    scopus 로고
    • Influence of the presence of an upstream annular liquid film on the wet gas flow measured by a Venturi in a downward vertical configuration
    • DOI 10.1016/j.flowmeasinst.2006.09.002, PII S0955598606000483
    • A. Lupeau, B. Platet, P. Gajan, A. Strzelecki, J. Escande, and J. P. Couput, "Influence of the presence of an upstream annular liquid film on the wet gas flow measured by a Venturi in a downward vertical configuration," Flow Meas. Instrum., vol. 18, no. 1, pp. 1-11, Mar. 2007. (Pubitemid 46296667)
    • (2007) Flow Measurement and Instrumentation , vol.18 , Issue.1 , pp. 1-11
    • Lupeau, A.1    Platet, B.2    Gajan, P.3    Strzelecki, A.4    Escande, J.5    Couput, J.P.6
  • 9
    • 0035300855 scopus 로고    scopus 로고
    • Discharge coefficients of Venturi tubes with standard and non-standard convergent angles
    • DOI 10.1016/S0955-5986(01)00007-3, PII S0955598601000073
    • M. J. Reader-Harris, W. C. Brunton, J. J. Gibson, D. Hodges, and I. G. Nicholson, "Discharge coefficients of Venturi tubes with standard and non-standard convergent angles," Flow Meas. Instrum., vol. 12, no. 2, pp. 135-145, Apr. 2001. (Pubitemid 32593061)
    • (2001) Flow Measurement and Instrumentation , vol.12 , Issue.2 , pp. 135-145
    • Reader-Harris, M.J.1    Brunton, W.C.2    Gibson, J.J.3    Hodges, D.4    Nicholson, I.G.5
  • 10
    • 67849088623 scopus 로고    scopus 로고
    • Horizontally installed cone differential pressure meter wet gas flow performance
    • Aug.-Oct.
    • R. Steven, "Horizontally installed cone differential pressure meter wet gas flow performance," Flow Meas. Instrum., vol. 20, no. 4/5, pp. 152-167, Aug.-Oct. 2009.
    • (2009) Flow Meas. Instrum. , vol.20 , Issue.4-5 , pp. 152-167
    • Steven, R.1
  • 11
    • 19544392838 scopus 로고    scopus 로고
    • Tomography for multi-phase flow measurement in the oil industry
    • DOI 10.1016/j.flowmeasinst.2005.02.017, PII S095559860500021X, Tomographic Techniques for Multiphase Flow Measurements
    • I. Ismail, J. C. Gamio, S. F. A. Bukhari, andW. Q. Yang, "Tomography for multi-phase flow measurement in the oil industry," Flow Meas. Instrum., vol. 16, no. 2/3, pp. 145-155, Apr.-Jun. 2005. (Pubitemid 40735358)
    • (2005) Flow Measurement and Instrumentation , vol.16 , Issue.2-3 , pp. 145-155
    • Ismail, I.1    Gamio, J.C.2    Bukhari, S.F.A.3    Yang, W.Q.4
  • 12
    • 0030221911 scopus 로고    scopus 로고
    • Design of a flow metering process for two-phase dispersed flows
    • Aug.
    • C. Boyer and H. Lemonnier, "Design of a flow metering process for two-phase dispersed flows," Int. J. Multiphase Flow, vol. 22, no. 4, pp. 713-732, Aug. 1996.
    • (1996) Int. J. Multiphase Flow , vol.22 , Issue.4 , pp. 713-732
    • Boyer, C.1    Lemonnier, H.2
  • 13
    • 1142275015 scopus 로고    scopus 로고
    • Liquid correction of Venturi meter readings in wet gas flow
    • Kristiansand, Norway
    • R. De Leeuw, "Liquid correction of Venturi meter readings in wet gas flow," in Proc. North Sea Flow Meas. Workshop, Kristiansand, Norway, 1997, p. 1.
    • (1997) Proc. North Sea Flow Meas. Workshop , pp. 1
    • De Leeuw, R.1
  • 14
    • 56049097505 scopus 로고    scopus 로고
    • Venturi wet gas flow modeling based on homogeneous and separated flow theory
    • Article ID: 807287, DOI: 10.1155/2008/807287
    • F. Lide, Z. Tao, and X. Ying, "Venturi wet gas flow modeling based on homogeneous and separated flow theory," Math. Probl. Eng., vol. 2008, pp. 1-25, 2008, Article ID: 807287, DOI: 10.1155/2008/807287.
    • (2008) Math. Probl. Eng. , vol.2008 , pp. 1-25
    • Lide, F.1    Tao, Z.2    Ying, X.3
  • 18
    • 33847673691 scopus 로고    scopus 로고
    • Absolute measurement of pneumatically conveyed powder using a single long throat venturi
    • DOI 10.1016/j.powtec.2006.10.044, PII S0032591006004712
    • D. Giddings, B. J. Azzopardi, A. Aroussi, and S. J. Pickering, "Absolute measurement of pneumatically conveyed powder using a single long throat Venturi," Powder Technol., vol. 172, no. 3, pp. 149-156, 2007. (Pubitemid 46356408)
    • (2007) Powder Technology , vol.172 , Issue.3 , pp. 149-156
    • Giddings, D.1    Azzopardi, B.J.2    Aroussi, A.3    Pickering, S.J.4
  • 21
    • 77957829899 scopus 로고    scopus 로고
    • Wet gas flowmodeling for the straight section of throat-extended Venturi meter
    • Austin, TX, May 3-6
    • W. L. Zhou, L. J. Xu, and X. M. Li, "Wet gas flowmodeling for the straight section of throat-extended Venturi meter," in Proc. IEEE Int. Instrum. Meas. Technol. Conf., Austin, TX, May 3-6, 2010, pp. 229-233.
    • (2010) Proc. IEEE Int. Instrum. Meas. Technol. Conf. , pp. 229-233
    • Zhou, W.L.1    Xu, L.J.2    Li, X.M.3
  • 22
    • 0026849153 scopus 로고
    • Void fraction prediction in two-phase flow across a tube bundle
    • Apr.
    • R. Dowlati, M. Kawaji, D. Chisholm, and A. Chan, "Void fraction prediction in two-phase flow across a tube bundle," AIChE J., vol. 38, no. 4, pp. 619-622, Apr. 1992.
    • (1992) AIChE J. , vol.38 , Issue.4 , pp. 619-622
    • Dowlati, R.1    Kawaji, M.2    Chisholm, D.3    Chan, A.4
  • 23
    • 0034333591 scopus 로고    scopus 로고
    • An improved void fraction model for two-phase cross-flow in horizontal tube bundles
    • Nov.
    • P. A. Feenstra, D. S. Weaver, and R. L. Judd, "An improved void fraction model for two-phase cross-flow in horizontal tube bundles," Int. J. Multiphase Flow, vol. 26, no. 11, pp. 1851-1873, Nov. 2000.
    • (2000) Int. J. Multiphase Flow , vol.26 , Issue.11 , pp. 1851-1873
    • Feenstra, P.A.1    Weaver, D.S.2    Judd, R.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.