메뉴 건너뛰기




Volumn 17, Issue 2, 2006, Pages 123-128

Study on the metering characteristics of a slotted orifice for wet gas flow

Author keywords

Computational fluid dynamics; Multiphase flow meter; Slotted orifice meter; Two phase multipliers; Wet gas metering

Indexed keywords

COMPUTATIONAL FLUID DYNAMICS; COMPUTER SIMULATION; FLOWMETERS; MULTIPHASE FLOW; ORIFICES;

EID: 30544432108     PISSN: 09555986     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.flowmeasinst.2005.08.004     Document Type: Article
Times cited : (53)

References (7)
  • 1
    • 30544444787 scopus 로고    scopus 로고
    • Wet gas Venturi Metering
    • SPE 77350
    • D.G. Steward, G. Brown, D. Hodges. Wet gas Venturi Metering, in: SPE 77350, 2002, pp. 1-11
    • (2002) , pp. 1-11
    • Steward, D.G.1    Brown, G.2    Hodges, D.3
  • 4
    • 33746555431 scopus 로고    scopus 로고
    • Study on a new type of flow sensor for wet gas meter
    • The 4th ISMTMF, September 10, 2004, Hangzhou, China
    • Y.-F. Geng, S.-C. Feng. Study on a new type of flow sensor for wet gas meter, in: Advances in Multiphase Flows, vol. 1, in: The 4th ISMTMF, September 10, 2004, Hangzhou, China, 2004, pp 536-541
    • (2004) Advances in Multiphase Flows , vol.1 , pp. 536-541
    • Geng, Y.-F.1    Feng, S.-C.2
  • 6
    • 0035742047 scopus 로고    scopus 로고
    • Wet gas metering with a horizontally mounted Venturi meter
    • R.N. Steven Wet gas metering with a horizontally mounted Venturi meter Flow Measurement and Instrumentation 12 2002 361-372
    • (2002) Flow Measurement and Instrumentation , vol.12 , pp. 361-372
    • Steven, R.N.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.