메뉴 건너뛰기




Volumn 60, Issue 4, 2011, Pages 237-243

The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: Performance in patients with a low cardiac output status and a reduced left ventricular function

Author keywords

Cardiac output; Measurement techniques; Off pump coronary artery bypass

Indexed keywords

NORADRENALIN;

EID: 79955954697     PISSN: 20056419     EISSN: 20057563     Source Type: Journal    
DOI: 10.4097/kjae.2011.60.4.237     Document Type: Article
Times cited : (17)

References (27)
  • 1
    • 38349075756 scopus 로고    scopus 로고
    • Cardiac output monitoring: Basic science and clinical application
    • Jhanji S, Dawson J, Pearse RM. Cardiac output monitoring: basic science and clinical application. Anaesthesia 2008; 63: 172-81.
    • (2008) Anaesthesia , vol.63 , pp. 172-181
    • Jhanji, S.1    Dawson, J.2    Pearse, R.M.3
  • 2
    • 0037413466 scopus 로고    scopus 로고
    • Canadian Critical Care Clinical Trials Group. A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients
    • Sandham JD, Hull RD, Brant RF, Knox L, Pineo GF, Doig CJ, et al. Canadian Critical Care Clinical Trials Group. A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med 2003; 348: 5-14.
    • (2003) N Engl J Med , vol.348 , pp. 5-14
    • Sandham, J.D.1    Hull, R.D.2    Brant, R.F.3    Knox, L.4    Pineo, G.F.5    Doig, C.J.6
  • 3
    • 26844502897 scopus 로고    scopus 로고
    • Edwards FloTrac sensor and Vigileo monitor: Easy, accurate, reliable cardiac output assessment using the arterial pulse wave
    • Manecke GR. Edwards FloTrac sensor and Vigileo monitor: easy, accurate, reliable cardiac output assessment using the arterial pulse wave. Expert Rev Med Devices 2005; 2: 523-7.
    • (2005) Expert Rev Med Devices , vol.2 , pp. 523-527
    • Manecke, G.R.1
  • 4
    • 34247551188 scopus 로고    scopus 로고
    • Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements
    • Sander M, Spies CD, Grubitzsch H, Foer A, Müller M, von Heymann C. Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements. Crit Care 2006; 10: R164.
    • (2006) Crit Care , vol.10
    • Sander, M.1    Spies, C.D.2    Grubitzsch, H.3    Foer, A.4    Müller, M.5    von Heymann, C.6
  • 5
    • 33847753396 scopus 로고    scopus 로고
    • Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: A comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery
    • Mayer J, Boldt J, Schöllhorn T, Röhm KD, Mengistu AM, Suttner S. Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery. Br J Anaesth 2007; 98: 176-82.
    • (2007) Br J Anaesth , vol.98 , pp. 176-182
    • Mayer, J.1    Boldt, J.2    Schöllhorn, T.3    Röhm, K.D.4    Mengistu, A.M.5    Suttner, S.6
  • 6
    • 34547699294 scopus 로고    scopus 로고
    • Validation of a new arterial pulse contour-based cardiac output device
    • de Waal EE, Kalkman CJ, Rex S, Buhre WF. Validation of a new arterial pulse contour-based cardiac output device. Crit Care Med 2007; 35: 1904-9.
    • (2007) Crit Care Med , vol.35 , pp. 1904-1909
    • de Waal, E.E.1    Kalkman, C.J.2    Rex, S.3    Buhre, W.F.4
  • 7
    • 33846669409 scopus 로고    scopus 로고
    • Cardiac output determination from the arterial pressure wave: Clinical testing of a novel algorithm that does not require calibration
    • Manecke GR Jr, Auger WR. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration. J Cardiothorac Vasc Anesth 2007; 21: 3-7.
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , pp. 3-7
    • Manecke Jr, G.R.1    Auger, W.R.2
  • 8
    • 34548266524 scopus 로고    scopus 로고
    • Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery
    • Button D, Weibel L, Reuthebuch O, Genoni M, Zollinger A, Hofer CK. Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery. Br J Anaesth 2007; 99: 329-36.
    • (2007) Br J Anaesth , vol.99 , pp. 329-336
    • Button, D.1    Weibel, L.2    Reuthebuch, O.3    Genoni, M.4    Zollinger, A.5    Hofer, C.K.6
  • 9
    • 39749138803 scopus 로고    scopus 로고
    • Cardiac output derived from arterial pressure waveform analysis in patients undergoing cardiac surgery: Validity of a second generation device
    • Mayer J, Boldt J, Wolf MW, Lang J, Suttner S. Cardiac output derived from arterial pressure waveform analysis in patients undergoing cardiac surgery: validity of a second generation device. Anesth Analg 2008; 106: 867-72.
    • (2008) Anesth Analg , vol.106 , pp. 867-872
    • Mayer, J.1    Boldt, J.2    Wolf, M.W.3    Lang, J.4    Suttner, S.5
  • 10
    • 44049091046 scopus 로고    scopus 로고
    • Cardiac output monitoring: Comparison of a new arterial pressure waveform analysis to the bolus thermodilution technique in patients undergoing off-pump coronary artery bypass surgery
    • Mehta Y, Chand RK, Sawhney R, Bhise M, Singh A, Trehan N. Cardiac output monitoring: comparison of a new arterial pressure waveform analysis to the bolus thermodilution technique in patients undergoing off-pump coronary artery bypass surgery. J Cardiothorac Vasc Anesth 2008; 22: 394-9.
    • (2008) J Cardiothorac Vasc Anesth , vol.22 , pp. 394-399
    • Mehta, Y.1    Chand, R.K.2    Sawhney, R.3    Bhise, M.4    Singh, A.5    Trehan, N.6
  • 11
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 34548208591 scopus 로고    scopus 로고
    • Using the Bland-Altman method to measure agreement with repeated measures
    • Myles PS, Cui J. Using the Bland-Altman method to measure agreement with repeated measures. Br J Anaesth 2007; 99: 309-11.
    • (2007) Br J Anaesth , vol.99 , pp. 309-311
    • Myles, P.S.1    Cui, J.2
  • 13
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999; 15: 85-91.
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 14
    • 68849125061 scopus 로고    scopus 로고
    • Pulse contour cardiac output: An evaluation of the FloTrac method
    • Østergaard M, Nielsen J, Nygaard E. Pulse contour cardiac output: an evaluation of the FloTrac method. Eur J Anaesthesiol 2009; 26: 484-9.
    • (2009) Eur J Anaesthesiol , vol.26 , pp. 484-489
    • østergaard, M.1    Nielsen, J.2    Nygaard, E.3
  • 15
    • 33748923649 scopus 로고    scopus 로고
    • Agreement between PiCCO pulse-contour analysis, pulmonal artery thermodilution and transthoracic thermodilution during off-pump coronary artery by-pass surgery
    • Halvorsen PS, Espinoza A, Lundblad R, Cvancarova M, Hol PK, Fosse E, et al. Agreement between PiCCO pulse-contour analysis, pulmonal artery thermodilution and transthoracic thermodilution during off-pump coronary artery by-pass surgery. Acta Anaesthesiol Scand 2006; 50: 1050-7.
    • (2006) Acta Anaesthesiol Scand , vol.50 , pp. 1050-1057
    • Halvorsen, P.S.1    Espinoza, A.2    Lundblad, R.3    Cvancarova, M.4    Hol, P.K.5    Fosse, E.6
  • 17
    • 67349233520 scopus 로고    scopus 로고
    • Cardiac index value measurement by invasive, semi-invasive and non invasive techniques: A prospective study in postoperative off pump coronary artery bypass surgery patients
    • Chakravarthy M, Rajeev S, Jawali V. Cardiac index value measurement by invasive, semi-invasive and non invasive techniques: a prospective study in postoperative off pump coronary artery bypass surgery patients. J Clin Monit Comput 2009; 23: 175-80.
    • (2009) J Clin Monit Comput , vol.23 , pp. 175-180
    • Chakravarthy, M.1    Rajeev, S.2    Jawali, V.3
  • 18
    • 0021347103 scopus 로고
    • Wave reflections and the arterial pulse
    • O'Rourke MF, Yaginuma T. Wave reflections and the arterial pulse. Arch Intern Med 1984; 144: 366-71.
    • (1984) Arch Intern Med , vol.144 , pp. 366-371
    • O'Rourke, M.F.1    Yaginuma, T.2
  • 20
    • 42449103530 scopus 로고    scopus 로고
    • Cardiac output measurement in patients undergoing liver transplantation: Pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis
    • Biais M, Nouette-Gaulain K, Cottenceau V, Vallet A, Cochard JF, Revel P, et al. Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis. Anesth Analg 2008; 106: 1480-6.
    • (2008) Anesth Analg , vol.106 , pp. 1480-1486
    • Biais, M.1    Nouette-Gaulain, K.2    Cottenceau, V.3    Vallet, A.4    Cochard, J.F.5    Revel, P.6
  • 21
    • 34548655920 scopus 로고    scopus 로고
    • Continuous cardiac output measurement: Arterial pressure analysis versus thermodilution technique during cardiac surgery with cardiopulmonary bypass
    • Lorsomradee S, Lorsomradee SR, Cromheecke S, De Hert SG. Continuous cardiac output measurement: arterial pressure analysis versus thermodilution technique during cardiac surgery with cardiopulmonary bypass. Anaesthesia 2007; 62: 979-83.
    • (2007) Anaesthesia , vol.62 , pp. 979-983
    • Lorsomradee, S.1    Lorsomradee, S.R.2    Cromheecke, S.3    de Hert, S.G.4
  • 22
    • 34648831355 scopus 로고    scopus 로고
    • Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: Effects of alterations in arterial waveform
    • Lorsomradee S, Lorsomradee S, Cromheecke S, De Hert SG. Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform. J Cardiothorac Vasc Anesth 2007; 21: 636-43.
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , pp. 636-643
    • Lorsomradee, S.1    Lorsomradee, S.2    Cromheecke, S.3    de Hert, S.G.4
  • 23
    • 0017251916 scopus 로고
    • Arterial pressure contour analysis for estimating human vascular properties
    • Watt TB Jr, Burrus CS. Arterial pressure contour analysis for estimating human vascular properties. J Appl Physiol 1976; 40: 171-6.
    • (1976) J Appl Physiol , vol.40 , pp. 171-176
    • Watt Jr, T.B.1    Burrus, C.S.2
  • 25
    • 0028605517 scopus 로고
    • Comparison of cardiac output measurement by continuous thermo-dilution with electromagnetometry in adult cardiac surgical patients
    • Hogue CW Jr, Rosenbloom M, McCawley C, Lappas DG. Comparison of cardiac output measurement by continuous thermo-dilution with electromagnetometry in adult cardiac surgical patients. J Cardiothorac Vasc Anesth 1994; 8: 631-5.
    • (1994) J Cardiothorac Vasc Anesth , vol.8 , pp. 631-635
    • Hogue Jr, C.W.1    Rosenbloom, M.2    McCawley, C.3    Lappas, D.G.4
  • 26
    • 34548342691 scopus 로고    scopus 로고
    • Clinical relevance of data from the pulmonary artery catheter
    • Robin E, Costecalde M, Lebuffe G, Vallet B. Clinical relevance of data from the pulmonary artery catheter. Crit Care 2006; 10 Suppl 3: S3.
    • Crit Care 2006 , vol.10 , Issue.3
    • Robin, E.1    Costecalde, M.2    Lebuffe, G.3    Vallet, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.