메뉴 건너뛰기




Volumn 29, Issue 7, 2011, Pages 976-983

Does high-flexion total knee arthroplasty promote early loosening of the femoral component?

Author keywords

femoral loosening; finite element analysis; high flexion; implant cement interface; total knee arthroplasty

Indexed keywords

ARTICLE; ENDOPROSTHESIS LOOSENING; KNEE FUNCTION; LOAD CARRYING CAPACITY; PRIORITY JOURNAL; PROSTHESIS FIXATION; RANGE OF MOTION; SHEAR STRESS; TENSILE STRENGTH; TOTAL KNEE REPLACEMENT;

EID: 79955922923     PISSN: 07360266     EISSN: 1554527X     Source Type: Journal    
DOI: 10.1002/jor.21363     Document Type: Article
Times cited : (55)

References (23)
  • 3
    • 37249046365 scopus 로고    scopus 로고
    • High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement
    • DOI 10.1302/0301-620X.89B11.19840
    • Han HS, Kang SB, Yoon KS., 2007. High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg Br 89: 1457-1461. (Pubitemid 350273239)
    • (2007) Journal of Bone and Joint Surgery - Series B , vol.89 , Issue.11 , pp. 1457-1461
    • Han, H.S.1    Kang, S.-B.2    Yoon, K.S.3
  • 5
    • 23044441339 scopus 로고    scopus 로고
    • The early results of high-flex total knee arthroplasty: A minimum of 2 years of follow-up
    • Huang HT, Su JY, Wang GJ., 2005. The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up. J Arthroplasty 20: 674-679.
    • (2005) J Arthroplasty , vol.20 , pp. 674-679
    • Huang, H.T.1    Su, J.Y.2    Wang, G.J.3
  • 6
    • 21444455369 scopus 로고    scopus 로고
    • Range of motion of standard and high-flexion posterior stabilized total knee prostheses
    • Kim YH, Sohn KS, Kim JS., 2005. Range of motion of standard and high-flexion posterior stabilized total knee prostheses. J Bone Joint Surg Am 87: 1470-1475.
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 1470-1475
    • Kim, Y.H.1    Sohn, K.S.2    Kim, J.S.3
  • 7
    • 0036137726 scopus 로고    scopus 로고
    • Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis
    • DOI 10.1016/S0021-9290(01)00179-8, PII S0021929001001798
    • Godest AC, Beaugonin M, Haug E, et al. 2002. Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis. J Biomech 35: 267-275. (Pubitemid 34037102)
    • (2002) Journal of Biomechanics , vol.35 , Issue.2 , pp. 267-275
    • Godest, A.C.1    Beaugonin, M.2    Haug, E.3    Taylor, M.4    Gregson, P.J.5
  • 8
    • 28544441161 scopus 로고    scopus 로고
    • Polymer insert stress in total knee designs during high-flexion activities: A finite element study
    • DOI 10.2106/JBJS.E.00436
    • Morra EA, Greenwald AS., 2005. Polymer insert stress in total knee designs during high-flexion activities: a finite element study. J Bone Joint Surg Am 87 (Suppl 2): 120-124. (Pubitemid 41747023)
    • (2005) Journal of Bone and Joint Surgery - Series A , vol.87 , Issue.12 SUPPL. , pp. 120-124
    • Morra, E.A.1    Greenwald, A.S.2
  • 9
    • 47649107254 scopus 로고    scopus 로고
    • A mechanical comparison of high-flexion and conventional total knee arthroplasty
    • et al.
    • Barink M, De Waal Malefijt M, Celada P, et al. 2008. A mechanical comparison of high-flexion and conventional total knee arthroplasty. Proc Inst Mech Eng H 222: 297-307.
    • (2008) Proc Inst Mech Eng H , vol.222 , pp. 297-307
    • Barink, M.1    De Waal Malefijt, M.2    Celada, P.3
  • 10
    • 0029790390 scopus 로고    scopus 로고
    • Mechanical effects of stem cement interface characteristics in total hip replacement
    • Verdonschot N, Huiskes R., 1996. Mechanical effects of stem cement interface characteristics in total hip replacement. Clin Orthop Relat Res 329: 326-336. (Pubitemid 26274687)
    • (1996) Clinical Orthopaedics and Related Research , Issue.329 , pp. 326-336
    • Verdonschot, N.1    Huiskes, R.2
  • 11
    • 13844298848 scopus 로고    scopus 로고
    • Analysis of the debonding of the stem-cement interface in intramedullary fixation using a non-linear fracture mechanics approach
    • Perez MA, Garcia JM, Doblare GM., 2005. Analysis of the debonding of the stem-cement interface in intramedullary fixation using a non-linear fracture mechanics approach. Eng Fract Mech 72: 1125-1147.
    • (2005) Eng Fract Mech , vol.72 , pp. 1125-1147
    • Perez, M.A.1    Garcia, J.M.2    Doblare, G.M.3
  • 13
    • 0020116475 scopus 로고
    • Forces during squatting and rising from a deep squat
    • DOI 10.1243/EMED-JOUR-1982-011-019-02
    • Dahlkvist NJ, Mayo P, Seedhom BB., 1982. Forces during squatting and rising from a deep squat. Eng Med 11: 69-76. (Pubitemid 12083359)
    • (1982) Engineering in Medicine , vol.11 , Issue.2 , pp. 69-76
    • Dahlkvist, N.J.1    Mayo, P.2    Seedhom, B.B.3
  • 14
    • 61849099957 scopus 로고    scopus 로고
    • Thigh-calf contact: Does it affect the loading of the knee in the high-flexion range
    • Zelle J, Barink M, De Waal MM, Verdonschot N., 2009. Thigh-calf contact: does it affect the loading of the knee in the high-flexion range ? J Biomech 42: 587-593.
    • (2009) J Biomech , vol.42 , pp. 587-593
    • Zelle, J.1    Barink, M.2    De Waal, M.M.3    Verdonschot, N.4
  • 15
    • 2642556592 scopus 로고    scopus 로고
    • Comparison of in situ and in vitro CT scan-based finite element model predictions of proximal femoral fracture load
    • DOI 10.1016/S1350-4533(03)00081-X, PII S135045330300081X
    • Keyak JH, Falkinstein Y., 2003. Comparison of in situ and in vitro CT scan-based finite element model predictions of proximal femoral fracture load. Med Eng Phys 25: 781-787. (Pubitemid 39089844)
    • (2003) Medical Engineering and Physics , vol.25 , Issue.9 , pp. 781-787
    • Keyak, J.H.1    Falkinstein, Y.2
  • 16
    • 0032071068 scopus 로고    scopus 로고
    • Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement
    • DOI 10.1016/S0021-9290(98)00030-X, PII S002192909800030X
    • Kurtz SM, Ochoa JA, White CV, et al. 1998. Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement. J Biomech 31: 431-437. (Pubitemid 28408341)
    • (1998) Journal of Biomechanics , vol.31 , Issue.5 , pp. 431-437
    • Kurtz, S.M.1    Ochoa, J.A.2    White, C.V.3    Srivastav, S.4    Cournoyer, J.5
  • 17
    • 79955900262 scopus 로고    scopus 로고
    • Mixed-mode failure strength of implant-cement interface specimens with varying surface roughness
    • et al. (in press).
    • Zelle J, Janssen D, Peeters S, et al. 2010. Mixed-mode failure strength of implant-cement interface specimens with varying surface roughness. J Biomech (in press).
    • (2010) J Biomech
    • Zelle, J.1    Janssen, D.2    Peeters, S.3
  • 18
    • 0001546191 scopus 로고
    • The brittle strength of orthotropic materials
    • Hoffman O., 1967. The brittle strength of orthotropic materials. J Comp Mat 1: 200-206.
    • (1967) J Comp Mat , vol.1 , pp. 200-206
    • Hoffman, O.1
  • 19
    • 0031106829 scopus 로고    scopus 로고
    • A kinematic-freedom analysis of a flexed-knee-stance testing Rig
    • DOI 10.1016/S0021-9290(96)00142-X, PII S002192909600142X
    • Zavatsky AB., 1997. A kinematic-freedom analysis of a flexed-knee-stance testing rig. J Biomech 30: 277-280. (Pubitemid 27077500)
    • (1997) Journal of Biomechanics , vol.30 , Issue.3 , pp. 277-280
    • Zavatsky, A.B.1
  • 20
    • 45849096048 scopus 로고    scopus 로고
    • How critical are the tibiofemoral joint reaction forces during frequent squatting in Asian populations
    • Thambyah A., 2008. How critical are the tibiofemoral joint reaction forces during frequent squatting in Asian populations ? Knee 15: 286-294.
    • (2008) Knee , vol.15 , pp. 286-294
    • Thambyah, A.1
  • 22
    • 79955887302 scopus 로고    scopus 로고
    • Successful results with a high flexion posterior stabilised knee prosthesis
    • Electronic Letter to Editor. Published online at 21 December 2007. See.
    • Scuderi GR., 2007. Successful results with a high flexion posterior stabilised knee prosthesis. J Bone Joint Surg Br. Electronic Letter to Editor. Published online at 21 December 2007. See:.
    • (2007) J Bone Joint Surg Br.
    • Scuderi, G.R.1
  • 23
    • 67349104391 scopus 로고    scopus 로고
    • Cementing the femoral component in total knee arthroplasty: Which technique is the best
    • Vaninbroukx M, Labey L, Innocenti B, Bellemans J., 2009. Cementing the femoral component in total knee arthroplasty: which technique is the best ? Knee 16: 265-268.
    • (2009) Knee , vol.16 , pp. 265-268
    • Vaninbroukx, M.1    Labey, L.2    Innocenti, B.3    Bellemans, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.