메뉴 건너뛰기




Volumn 7964, Issue , 2011, Pages

Architecture of a high-performance surgical guidance system based on C-arm cone-beam CT: Software platform for technical integration and clinical translation

Author keywords

Augmented reality; Cone beam CT; Digitally reconstructed radiograph; Image guided surgery; Image registration; Intraoperative imaging; Surgical navigation

Indexed keywords

CONE-BEAM CT; DIGITALLY RECONSTRUCTED RADIOGRAPHS; IMAGE GUIDED SURGERY; INTRA-OPERATIVE; SURGICAL NAVIGATION;

EID: 79955795665     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.878191     Document Type: Conference Paper
Times cited : (6)

References (12)
  • 1
    • 12844254281 scopus 로고    scopus 로고
    • Volume CT with a flat-panel detector on a mobile, isocentric C-arm: Pre-clinical investigation in guidance of minimally invasive surgery
    • DOI 10.1118/1.1836331
    • Siewerdsen, J., H., et al., "Volume CT with a flat-panel detector on a mobile, isocentric C-arm: Pre-clinical investigation in guidance of minimally invasive surgery, " Med. Phys. 32(1), 241-54 (Jan 2005). (Pubitemid 40165536)
    • (2005) Medical Physics , vol.32 , Issue.1 , pp. 241-254
    • Siewerdsen, J.H.1    Moseley, D.J.2    Burch, S.3    Bisland, S.K.4    Bogaards, A.5    Wilson, B.C.6    Jaffray, D.A.7
  • 6
    • 70349658747 scopus 로고    scopus 로고
    • Demons deformable registration for CBCT-guided procedures in the head and neck: Convergence and accuracy
    • (Oct.)
    • Nithiananthan, S., Brock, K., K., Daly, M., J., Chan, H., Irish, J., C., Siewerdsen, J., H., "Demons deformable registration for CBCT-guided procedures in the head and neck: convergence and accuracy, " Med. Phys. 36(10) 4755-64 (Oct 2009).
    • (2009) Med. Phys. , vol.36 , Issue.10 , pp. 4755-4764
    • Nithiananthan, S.1    Brock, K.K.2    Daly, M.J.3    Chan, H.4    Irish, J.C.5    Siewerdsen, J.H.6
  • 7
    • 84975553202 scopus 로고
    • Closed form solution of absolute orientation using unit quarternions
    • (Apr.)
    • Horn, B., K., P., "Closed form solution of absolute orientation using unit quarternions, " J. Opt. Soc. America, 4(4), 629-642 (Apr 1987).
    • (1987) J. Opt. Soc. America , vol.4 , Issue.4 , pp. 629-642
    • Horn, B.K.P.1
  • 8
    • 65449146670 scopus 로고    scopus 로고
    • Automatic image-to-world registration based on x-ray projections in cone-beam CT-guided interventions
    • (May)
    • Hamming, N., M., Daly, M., J., Irish, J., C., Siewerdsen J., H., "Automatic image-to-world registration based on x-ray projections in cone-beam CT-guided interventions, " Med. Phys. 36(5), 1800-12 (May 2009).
    • (2009) Med. Phys. , vol.36 , Issue.5 , pp. 1800-1812
    • Hamming, N.M.1    Daly, M.J.2    Irish, J.C.3    Siewerdsen, J.H.4
  • 10
    • 0021952059 scopus 로고
    • Fast calculation of the exact radiological path for a three-dimensional CT array
    • DOI 10.1118/1.595715
    • Siddon, R., L., "Fast calculation of the exact radiological path for a three-dimensional CT array, " Med. Phys. 12(2), 252-255 (1985). (Pubitemid 15089015)
    • (1985) Medical Physics , vol.12 , Issue.2 , pp. 252-255
    • Siddon, R.L.1
  • 11
    • 79955818065 scopus 로고    scopus 로고
    • Deformable registration for cone-beam CT-guided surgery: Modified Demons for excised tissue
    • To Appear
    • Nithiananthan, S., et al., "Deformable registration for cone-beam CT-guided surgery: modified Demons for excised tissue, " Proc. SPIE Medical Imaging, To Appear (2011).
    • (2011) Proc. SPIE Medical Imaging
    • Nithiananthan, S.1
  • 12
    • 79955856845 scopus 로고    scopus 로고
    • High-accuracy 3D image-based registration of endoscopic video to C-arm cone-beam CT for image-guided skull-base surgery
    • To Appear
    • Mirota, D., et al., "High-accuracy 3D image-based registration of endoscopic video to C-arm cone-beam CT for image-guided skull-base surgery, " Proc. SPIE Medical Imaging, To Appear (2011).
    • (2011) Proc. SPIE Medical Imaging
    • Mirota, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.