-
1
-
-
84863534817
-
-
IEC, International Standard, International Electrotechnical Commission, Geneva, Switzerland, February
-
IEC, "CEI/IEC 60601-2-44:2009 Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography Edition 3.0," International Standard, International Electrotechnical Commission, Geneva, Switzerland, February 2009.
-
(2009)
CEI/IEC 60601-2-44:2009 Medical Electrical Equipment - Part 2-44: Particular Requirements for the Basic Safety and Essential Performance of X-ray Equipment for Computed Tomography Edition 3.0
-
-
-
2
-
-
84863510179
-
-
IEC, International Standard, International Electrotechnical Commission, Geneva, Switzerland, November
-
IEC, "CEI/IEC 61223-2-6:2006 Evaluation and routine testing in medical imaging departments - Part 2-6: Constancy tests - Imaging performance of computed tomography X-ray equipment Edition 2.0," International Standard, International Electrotechnical Commission, Geneva, Switzerland, November 2006.
-
(2006)
CEI/IEC 61223-2-6:2006 Evaluation and Routine Testing in Medical Imaging Departments - Part 2-6: Constancy Tests - Imaging Performance of Computed Tomography X-ray Equipment Edition 2.0
-
-
-
3
-
-
79955754761
-
-
IEC, International Standard, International Electrotechnical Commission, Geneva, Switzerland, November
-
IEC, "CEI/IEC 61223-3-5:2004 Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - Imaging performance of computed tomography X-ray equipment," International Standard, International Electrotechnical Commission, Geneva, Switzerland, November 2004.
-
(2004)
CEI/IEC 61223-3-5:2004 Evaluation and Routine Testing in Medical Imaging Departments - Part 3-5: Acceptance Tests - Imaging Performance of Computed Tomography X-ray Equipment
-
-
-
4
-
-
0018367387
-
Application of information theory to the assessment of computed tomography
-
DOI 10.1118/1.594559
-
R. Wagner, D. Brown, and M. Pastel, "Application of information theory to the assessment of computed tomgraphy," Medical Physics 6, pp. 83-94, 1979. (Pubitemid 9168374)
-
(1979)
Medical Physics
, vol.6
, Issue.2
, pp. 83-94
-
-
Wagner, R.F.1
Brown, D.G.2
Pastel, M.S.3
-
5
-
-
0018733995
-
Detectability in computed tomographic images
-
DOI 10.1118/1.594534
-
K. Hanson, "Detectability in computed tomographic images," Medical Physics 6, pp. 441-451, 1979. (Pubitemid 10244108)
-
(1979)
Medical Physics
, vol.6
, Issue.5
, pp. 441-451
-
-
Hanson, K.M.1
-
6
-
-
0003908117
-
-
ICRU, tech. rep., International Commission on Radiation Units and Measurements
-
ICRU, "Report 54: Medical imaging - The assessment of image quality," tech. rep., International Commission on Radiation Units and Measurements, 1996.
-
(1996)
Report 54: Medical Imaging - The Assessment of Image Quality
-
-
-
7
-
-
56749159109
-
Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT
-
D. J. Tward and J. H. Siewerdsen, "Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT," Medical Physics 35, pp. 5510-5529, 2008.
-
(2008)
Medical Physics
, vol.35
, pp. 5510-5529
-
-
Tward, D.J.1
Siewerdsen, J.H.2
-
8
-
-
68149098899
-
Noise aliasing and the 3D NEQ of flat-panel cone-beam CT: Effect of 2D/3D apertures and sampling
-
D. J. Tward and J. H. Siewerdsen, "Noise aliasing and the 3D NEQ of flat-panel cone-beam CT: Effect of 2D/3D apertures and sampling," Medical Physics 36, pp. 3830-3843, 2009.
-
(2009)
Medical Physics
, vol.36
, pp. 3830-3843
-
-
Tward, D.J.1
Siewerdsen, J.H.2
-
9
-
-
0019913387
-
A practical method to measure the MTF of CT scanners
-
DOI 10.1118/1.595124
-
R. T. Droege and R. L. Morin, "A practical method to measure the MTF of CT scanners," Medical Physics 9, pp. 758-760, 1982. (Pubitemid 12003678)
-
(1982)
Medical Physics
, vol.9
, Issue.5
, pp. 758-760
-
-
Droege, R.T.1
Morin, R.L.2
-
10
-
-
0033088416
-
The Rose model, revisited
-
A. Burgess, "The Rose model, revisited," Journal of the Optical Society of America A 16, pp. 633-646, 1999. (Pubitemid 129582210)
-
(1999)
Journal of the Optical Society of America A: Optics and Image Science, and Vision
, vol.16
, Issue.3
, pp. 633-646
-
-
Burgess, A.E.1
-
11
-
-
0022135615
-
Effect of noise correlation on detectability of disk signals in medical imaging
-
K. J. Myers, H. H. Barrett, M. C. Borgstrom, D. D. Patton, and G. W. Seeley, "Effect of noise correlation on detectability of disk signals in medical imaging," J. Opt. Soc. Am. A 2, pp. 1752-1759, 1985.
-
(1985)
J. Opt. Soc. Am. A
, vol.2
, pp. 1752-1759
-
-
Myers, K.J.1
Barrett, H.H.2
Borgstrom, M.C.3
Patton, D.D.4
Seeley, G.W.5
-
12
-
-
33845957018
-
Evaluation of the spatial resolution characteristics of a cone-beam breast CT scanner
-
DOI 10.1118/1.2400830
-
A. Kwan, J. Boone, K. Yang, and S.-Y. Huang, "Evaluation of the spatial resolution characteristics of a cone-beam breast CT scanner," Medical Physics 34, pp. 275-281, 2007. (Pubitemid 46035249)
-
(2007)
Medical Physics
, vol.34
, Issue.1
, pp. 275-281
-
-
Kwan, A.L.C.1
Boone, J.M.2
Yang, K.3
Huang, S.-Y.4
-
13
-
-
77953872191
-
Image quality dependence on in-plane positions and directions for MDCT images
-
T. Hara, K. Ichikawa, S. Sanada, and Y. Ida, "Image quality dependence on in-plane positions and directions for MDCT images," European Radiology 75, pp. 114-121, 2010.
-
(2010)
European Radiology
, vol.75
, pp. 114-121
-
-
Hara, T.1
Ichikawa, K.2
Sanada, S.3
Ida, Y.4
-
14
-
-
79953660322
-
Noise characterization of computed tomography using the covariance matrix
-
C. Brunner, S. Hurowitz, S. Abboud, C. Hoeschen, and I. Kyprianou, "Noise characterization of computed tomography using the covariance matrix," Proc. SPIE 7622, p. 76224Z, 2010.
-
(2010)
Proc. SPIE
, vol.7622
-
-
Brunner, C.1
Hurowitz, S.2
Abboud, S.3
Hoeschen, C.4
Kyprianou, I.5
|