메뉴 건너뛰기




Volumn 7961, Issue , 2011, Pages

Investigation of a method to estimate the MTF and NPS of CT towards creating an international standard

Author keywords

Computed tomography; MTF; NPS; SNR

Indexed keywords

AXIAL PLANES; COMPUTED TOMOGRAPHY; CT IMAGE; CT SCANNERS; FOURIER; IEC STANDARDS; INTERNATIONAL STANDARDS; MODULATION TRANSFER FUNCTION; MTF; NOISE POWER SPECTRUM; NPS; POINT-SPREAD FUNCTIONS; RECONSTRUCTION ALGORITHMS; SIGNAL TO NOISE; SNR; SOURCE CURRENTS; SPATIAL CORRELATIONS; STANDARD DEVIATION; TUNGSTEN WIRES; WATER PHANTOM;

EID: 79955780959     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.877657     Document Type: Conference Paper
Times cited : (11)

References (14)
  • 4
    • 0018367387 scopus 로고
    • Application of information theory to the assessment of computed tomography
    • DOI 10.1118/1.594559
    • R. Wagner, D. Brown, and M. Pastel, "Application of information theory to the assessment of computed tomgraphy," Medical Physics 6, pp. 83-94, 1979. (Pubitemid 9168374)
    • (1979) Medical Physics , vol.6 , Issue.2 , pp. 83-94
    • Wagner, R.F.1    Brown, D.G.2    Pastel, M.S.3
  • 5
    • 0018733995 scopus 로고
    • Detectability in computed tomographic images
    • DOI 10.1118/1.594534
    • K. Hanson, "Detectability in computed tomographic images," Medical Physics 6, pp. 441-451, 1979. (Pubitemid 10244108)
    • (1979) Medical Physics , vol.6 , Issue.5 , pp. 441-451
    • Hanson, K.M.1
  • 6
    • 0003908117 scopus 로고    scopus 로고
    • ICRU, tech. rep., International Commission on Radiation Units and Measurements
    • ICRU, "Report 54: Medical imaging - The assessment of image quality," tech. rep., International Commission on Radiation Units and Measurements, 1996.
    • (1996) Report 54: Medical Imaging - The Assessment of Image Quality
  • 7
    • 56749159109 scopus 로고    scopus 로고
    • Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT
    • D. J. Tward and J. H. Siewerdsen, "Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT," Medical Physics 35, pp. 5510-5529, 2008.
    • (2008) Medical Physics , vol.35 , pp. 5510-5529
    • Tward, D.J.1    Siewerdsen, J.H.2
  • 8
    • 68149098899 scopus 로고    scopus 로고
    • Noise aliasing and the 3D NEQ of flat-panel cone-beam CT: Effect of 2D/3D apertures and sampling
    • D. J. Tward and J. H. Siewerdsen, "Noise aliasing and the 3D NEQ of flat-panel cone-beam CT: Effect of 2D/3D apertures and sampling," Medical Physics 36, pp. 3830-3843, 2009.
    • (2009) Medical Physics , vol.36 , pp. 3830-3843
    • Tward, D.J.1    Siewerdsen, J.H.2
  • 9
    • 0019913387 scopus 로고
    • A practical method to measure the MTF of CT scanners
    • DOI 10.1118/1.595124
    • R. T. Droege and R. L. Morin, "A practical method to measure the MTF of CT scanners," Medical Physics 9, pp. 758-760, 1982. (Pubitemid 12003678)
    • (1982) Medical Physics , vol.9 , Issue.5 , pp. 758-760
    • Droege, R.T.1    Morin, R.L.2
  • 11
    • 0022135615 scopus 로고
    • Effect of noise correlation on detectability of disk signals in medical imaging
    • K. J. Myers, H. H. Barrett, M. C. Borgstrom, D. D. Patton, and G. W. Seeley, "Effect of noise correlation on detectability of disk signals in medical imaging," J. Opt. Soc. Am. A 2, pp. 1752-1759, 1985.
    • (1985) J. Opt. Soc. Am. A , vol.2 , pp. 1752-1759
    • Myers, K.J.1    Barrett, H.H.2    Borgstrom, M.C.3    Patton, D.D.4    Seeley, G.W.5
  • 12
    • 33845957018 scopus 로고    scopus 로고
    • Evaluation of the spatial resolution characteristics of a cone-beam breast CT scanner
    • DOI 10.1118/1.2400830
    • A. Kwan, J. Boone, K. Yang, and S.-Y. Huang, "Evaluation of the spatial resolution characteristics of a cone-beam breast CT scanner," Medical Physics 34, pp. 275-281, 2007. (Pubitemid 46035249)
    • (2007) Medical Physics , vol.34 , Issue.1 , pp. 275-281
    • Kwan, A.L.C.1    Boone, J.M.2    Yang, K.3    Huang, S.-Y.4
  • 13
    • 77953872191 scopus 로고    scopus 로고
    • Image quality dependence on in-plane positions and directions for MDCT images
    • T. Hara, K. Ichikawa, S. Sanada, and Y. Ida, "Image quality dependence on in-plane positions and directions for MDCT images," European Radiology 75, pp. 114-121, 2010.
    • (2010) European Radiology , vol.75 , pp. 114-121
    • Hara, T.1    Ichikawa, K.2    Sanada, S.3    Ida, Y.4
  • 14
    • 79953660322 scopus 로고    scopus 로고
    • Noise characterization of computed tomography using the covariance matrix
    • C. Brunner, S. Hurowitz, S. Abboud, C. Hoeschen, and I. Kyprianou, "Noise characterization of computed tomography using the covariance matrix," Proc. SPIE 7622, p. 76224Z, 2010.
    • (2010) Proc. SPIE , vol.7622
    • Brunner, C.1    Hurowitz, S.2    Abboud, S.3    Hoeschen, C.4    Kyprianou, I.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.