메뉴 건너뛰기




Volumn 7961, Issue , 2011, Pages

Task-based comparative study of iterative image reconstruction methods for limited-angle x-ray tomography

Author keywords

[No Author keywords available]

Indexed keywords

AREA UNDER THE ROC CURVE; COMPARATIVE STUDIES; DIGITAL TOMOSYNTHESIS; ILL POSED; ITERATIVE IMAGE RECONSTRUCTION; LEAST SQUARES; LESION DETECTABILITY; LESION DETECTION; RECONSTRUCTION METHOD; RECONSTRUCTION PROBLEMS; SHAPE DISCRIMINATION; SIMULATION RESULT; SIMULTANEOUS ALGEBRAIC RECONSTRUCTION TECHNIQUE; TASK-BASED; TASK-BASED PERFORMANCE; TOTAL-VARIATION; X-RAY TOMOGRAPHY; X-RAY TOMOSYNTHESIS;

EID: 79955765961     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.878098     Document Type: Conference Paper
Times cited : (2)

References (17)
  • 1
    • 0141928682 scopus 로고    scopus 로고
    • Digital x-ray tomosynthesis: Current state of the art and clinical potential
    • JT. Dobbins III and DJ. Godfrey, "Digital x-ray tomosynthesis: current state of the art and clinical potential," Phys. Med. Biol., vol.48 (19), 2003.
    • (2003) Phys. Med. Biol. , vol.48 , Issue.19
    • Dobbins III, J.T.1    Godfrey, D.J.2
  • 2
    • 77950553921 scopus 로고    scopus 로고
    • Task-based assessment of breast tomosynthesis: Effect of acquisition parameters and quantum noise
    • I. Reiser and RM. Nishikawa, "Task-based assessment of breast tomosynthesis: Effect of acquisition parameters and quantum noise," Med. Phys., vol.37(4), 2010.
    • (2010) Med. Phys. , vol.37 , Issue.4
    • Reiser, I.1    Nishikawa, R.M.2
  • 3
    • 77953523692 scopus 로고    scopus 로고
    • Quantitative imaging in breast tomosynthesis and CT: Comparison of detection and estimation task performance
    • S. Richard and E. Samei, "Quantitative imaging in breast tomosynthesis and CT: Comparison of detection and estimation task performance," Med. Phys., vol.37 (3), 2010.
    • (2010) Med. Phys. , vol.37 , Issue.3
    • Richard, S.1    Samei, E.2
  • 4
    • 79955775871 scopus 로고    scopus 로고
    • Effects of projection-view distributions on image quality of calcifications in digital breast tomosynthesis (DBT) reconstruction
    • Y. Lu, HP. Chan, M .Goodsitt, J. Wei, L. Hadjiiski, A. Schmitz, JW. Eberhard, and BE H. Claus, "Effects of projection-view distributions on image quality of calcifications in digital breast tomosynthesis (DBT) reconstruction," Proc. SPIE 7622, 76220D, 2010.
    • (2010) Proc. SPIE , vol.7622
    • Lu, Y.1    Chan, H.P.2    Goodsitt, M.3    Wei, J.4    Hadjiiski, L.5    Schmitz, A.6    Eberhard, J.W.7    Claus, B.E.H.8
  • 5
    • 34748867737 scopus 로고    scopus 로고
    • Importance of point-by-point back projection correction for isocentric motion in digital breast tomosynthesis: Relevance to morphology of structures such as microcalcifications
    • Y. Chen, JY. Lo and JT. Dobbins III, "Importance of point-by-point back projection correction for isocentric motion in digital breast tomosynthesis: Relevance to morphology of structures such as microcalcifications," Med. Phys., vol.34(10), 2007.
    • (2007) Med. Phys. , vol.34 , Issue.10
    • Chen, Y.1    Lo, J.Y.2    Dobbins III, J.T.3
  • 7
    • 70350718948 scopus 로고    scopus 로고
    • Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms
    • EY. Sidky, X. Pan, IS. Reiser, and RM. Nishikawa, RH. Moore and DB. Kopans, " Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms," Med. Phys., vol.36(11), 2009;
    • (2009) Med. Phys. , vol.36 , Issue.11
    • Sidky, E.Y.1    Pan, X.2    Reiser, I.S.3    Nishikawa, R.M.4    Moore, R.H.5    Kopans, D.B.6
  • 8
    • 4644334876 scopus 로고    scopus 로고
    • A comparison of reconstruction algorithms for breast tomosynthesis
    • T. Wu, RH. Moore, EA. Rafferty, and DB. Kopans, "A comparison of reconstruction algorithms for breast tomosynthesis," Med. Phys., vol.31(9), 2004.
    • (2004) Med. Phys. , vol.31 , Issue.9
    • Wu, T.1    Moore, R.H.2    Rafferty, E.A.3    Kopans, D.B.4
  • 9
    • 33749404804 scopus 로고    scopus 로고
    • A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis
    • Y. Zhang, HP. Chan, B. Sahiner, J. Wei, MM. Goodsitt, LM. Hadjiiski, J. Ge, and C. Zhou, "A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis," Med. Phys., vol.33(10), 2006.
    • (2006) Med. Phys. , vol.33 , Issue.10
    • Zhang, Y.1    Chan, H.P.2    Sahiner, B.3    Wei, J.4    Goodsitt, M.M.5    Hadjiiski, L.M.6    Ge, J.7    Zhou, C.8
  • 10
    • 56749186140 scopus 로고    scopus 로고
    • Image artifacts in digital breast tomosynthesis: Investigation of the effects of system geometry and reconstruction parameters using a linear system approach
    • YH. Hu, B. Zhao, and W. Zhao, "Image artifacts in digital breast tomosynthesis: Investigation of the effects of system geometry and reconstruction parameters using a linear system approach," Med. Phys., vol.35(12), 2008.
    • (2008) Med. Phys. , vol.35 , Issue.12
    • Hu, Y.H.1    Zhao, B.2    Zhao, W.3
  • 11
    • 79955771190 scopus 로고    scopus 로고
    • Task-based performance analysis of SART for digital breast tomosynthesis using signal CNR and channelised Hotelling observers
    • D. Van de Sompel, M. Brady, CPS. Ho, and A McLennan, "Task-based performance analysis of SART for digital breast tomosynthesis using signal CNR and channelised Hotelling observers," Proc. SPIE 7622, 762211, 2010.
    • (2010) Proc. SPIE , vol.7622 , pp. 762211
    • Van De Sompel, D.1    Brady, M.2    Ho, C.P.S.3    McLennan, A.4
  • 12
    • 0024627075 scopus 로고
    • Algebraic reconstruction in CT from limited views
    • Mar
    • AH. Andersen , "Algebraic reconstruction in CT from limited views", IEEE trans. Med. Imag., vol.8(1), pp.50-55, Mar 1989.
    • (1989) IEEE Trans. Med. Imag. , vol.8 , Issue.1 , pp. 50-55
    • Andersen, A.H.1
  • 13
    • 0029394375 scopus 로고
    • Globally convergent algorithms for maximum a posteriori transmission tomography
    • K. Lange, JA. Fessler, "Globally convergent algorithms for maximum a posteriori transmission tomography," IEEE Trans. Imag. Process., vol.4(10), 1995
    • (1995) IEEE Trans. Imag. Process. , vol.4 , Issue.10
    • Lange, K.1    Fessler, J.A.2
  • 14
    • 0020913731 scopus 로고
    • Variations in task and the ideal observer
    • SPIE Medical imaging
    • KM. Hanson, "Variations in task and the ideal observer," Proc. Vol. 413, pp. 60-67, SPIE Medical imaging, 1983
    • (1983) Proc. , vol.413 , pp. 60-67
    • Hanson, K.M.1
  • 16
    • 21244503345 scopus 로고
    • Binary task performance on images reconstructed using MEMSYS 3: Comparison of machine and human observers
    • Kluwer Academic, Dordrecht
    • KJ. Myers, RF. Wagner, and KM. Hanson, "Binary task performance on images reconstructed using MEMSYS 3: Comparison of machine and human observers," Maximum Entropy and Bayesian Methods, pp. 415-421, Kluwer Academic, Dordrecht, 1993.
    • (1993) Maximum Entropy and Bayesian Methods , pp. 415-421
    • Myers, K.J.1    Wagner, R.F.2    Hanson, K.M.3
  • 17
    • 0027808792 scopus 로고
    • Rayleigh task performance in tomographic reconstructions: Comparison of human and machine performance
    • KJ. Myers, RF. Wagner, and KM. Hanson, "Rayleigh task performance in tomographic reconstructions: Comparison of human and machine performance," Medical Imaging: Image Processing, Proc. SPIE 1898, pp. 628-637, 1993.
    • (1898) Medical Imaging: Image Processing, Proc. SPIE , pp. 628-637
    • Myers, K.J.1    Wagner, R.F.2    Hanson, K.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.