메뉴 건너뛰기




Volumn 2, Issue 2, 2011, Pages 152-158

Cerebral Blood Flow Measurement in Neurosurgery

Author keywords

Acetazolamide challenge; Brain perfusion imaging; Cerebral blood flow; Cerebral hemodynamics; Perfusion computed tomography

Indexed keywords

ACETAZOLAMIDE;

EID: 79955719187     PISSN: 18684483     EISSN: 1868601X     Source Type: Journal    
DOI: 10.1007/s12975-010-0064-y     Document Type: Review
Times cited : (12)

References (28)
  • 1
    • 36448939753 scopus 로고    scopus 로고
    • Theoretical basis of hemodynamic MR imaging techniques to measure cerebral blood volume, cerebral blood flow, and permeability
    • Zaharchuk G. Theoretical basis of hemodynamic MR imaging techniques to measure cerebral blood volume, cerebral blood flow, and permeability. Am J Neuroradiol. 2007; 28(10): 1850-8.
    • (2007) Am J Neuroradiol , vol.28 , Issue.10 , pp. 1850-1858
    • Zaharchuk, G.1
  • 2
    • 34250674891 scopus 로고    scopus 로고
    • Measurement of cerebral perfusion with arterial spin labeling: part 1. Methods
    • Liu TT, Brown GG. Measurement of cerebral perfusion with arterial spin labeling: part 1. Methods. Int Neuropsychol Soc. 2007; 13(3): 517-25.
    • (2007) Int Neuropsychol Soc , vol.13 , Issue.3 , pp. 517-525
    • Liu, T.T.1    Brown, G.G.2
  • 3
    • 68249131679 scopus 로고    scopus 로고
    • Vascular graph model to simulate the cerebral blood flow in realistic vascular networks
    • Reichold J, Stampanoni M, Keller A, Buck A, Jenny P, Weber B. Vascular graph model to simulate the cerebral blood flow in realistic vascular networks. J Cereb Blood Flow Metab. 2009; 29(8): 1429-43.
    • (2009) J Cereb Blood Flow Metab , vol.29 , Issue.8 , pp. 1429-1443
    • Reichold, J.1    Stampanoni, M.2    Keller, A.3    Buck, A.4    Jenny, P.5    Weber, B.6
  • 4
    • 34547681727 scopus 로고    scopus 로고
    • Potential use of quantitative bedside CBF monitoring (xe-CT) for decision making in neurosurgical intensive care
    • Sturnegk P, Mellergard P, Yonas H, Theodorsson A, Hillman J. Potential use of quantitative bedside CBF monitoring (xe-CT) for decision making in neurosurgical intensive care. Br J Neurosurg. 2007; 21(4): 332-9.
    • (2007) Br J Neurosurg , vol.21 , Issue.4 , pp. 332-339
    • Sturnegk, P.1    Mellergard, P.2    Yonas, H.3    Theodorsson, A.4    Hillman, J.5
  • 5
    • 56349109411 scopus 로고    scopus 로고
    • Dose reduction in dynamic perfusion CT of the brain: effects of the scan frequency on measurements of cerebral blood flow, cerebral blood volume, and mean transit time
    • Wiesmann M, Berg S, Bohner G, Klingebiel R, Schopf V, Stoeckelhuber BM, et al. Dose reduction in dynamic perfusion CT of the brain: effects of the scan frequency on measurements of cerebral blood flow, cerebral blood volume, and mean transit time. Eur Radiol. 2008; 18(12): 2967-74.
    • (2008) Eur Radiol , vol.18 , Issue.12 , pp. 2967-2974
    • Wiesmann, M.1    Berg, S.2    Bohner, G.3    Klingebiel, R.4    Schopf, V.5    Stoeckelhuber, B.M.6
  • 6
    • 0035037004 scopus 로고    scopus 로고
    • Simultaneous measurement of regional cerebral blood flow by perfusion CT and stable xenon CT: a validation study
    • Wintermark M, Thiran JP, Maeder P, Schnyder P, Meuli R. Simultaneous measurement of regional cerebral blood flow by perfusion CT and stable xenon CT: a validation study. Am J Neuroradiol. 2001; 22(5): 905-14.
    • (2001) Am J Neuroradiol , vol.22 , Issue.5 , pp. 905-914
    • Wintermark, M.1    Thiran, J.P.2    Maeder, P.3    Schnyder, P.4    Meuli, R.5
  • 8
    • 35148896028 scopus 로고    scopus 로고
    • Absolute quantification of cerebral blood flow in normal volunteers: correlation between xe-133 SPECT and dynamic susceptibility contrast MRI
    • Knutsson L, Borjesson S, Larsson EM, Risberg J, Gustafson L, Passant U, et al. Absolute quantification of cerebral blood flow in normal volunteers: correlation between xe-133 SPECT and dynamic susceptibility contrast MRI. J Magn Reson Imag. 2007; 26(4): 913-20.
    • (2007) J Magn Reson Imag , vol.26 , Issue.4 , pp. 913-920
    • Knutsson, L.1    Borjesson, S.2    Larsson, E.M.3    Risberg, J.4    Gustafson, L.5    Passant, U.6
  • 10
    • 33748472373 scopus 로고    scopus 로고
    • Correlative assessment of cerebral blood flow obtained with perfusion CT and positron emission tomography in symptomatic stenotic carotid disease
    • Bisdas S, Nemitz O, Berding G, Weissenborn K, Ahl B, Becker H, et al. Correlative assessment of cerebral blood flow obtained with perfusion CT and positron emission tomography in symptomatic stenotic carotid disease. Eur Radiol. 2006; 16(10): 2220-8.
    • (2006) Eur Radiol , vol.16 , Issue.10 , pp. 2220-2228
    • Bisdas, S.1    Nemitz, O.2    Berding, G.3    Weissenborn, K.4    Ahl, B.5    Becker, H.6
  • 11
    • 50049128402 scopus 로고    scopus 로고
    • Accuracy of perfusion CT in predicting malignant middle cerebral artery brain infarction
    • Dittrich R, Kloska SP, Fischer T, Nam E, Ritter MA, Seidensticker P, et al. Accuracy of perfusion CT in predicting malignant middle cerebral artery brain infarction. J Neurol. 2008; 255(6): 896-902.
    • (2008) J Neurol , vol.255 , Issue.6 , pp. 896-902
    • Dittrich, R.1    Kloska, S.P.2    Fischer, T.3    Nam, E.4    Ritter, M.A.5    Seidensticker, P.6
  • 12
    • 56049099300 scopus 로고    scopus 로고
    • Comparison of PET and DW/PW-MRI in acute ischemic stroke
    • Heiss WD, Sobesky J. Comparison of PET and DW/PW-MRI in acute ischemic stroke. Keio J Med. 2008; 57(3): 125-31.
    • (2008) Keio J Med , vol.57 , Issue.3 , pp. 125-131
    • Heiss, W.D.1    Sobesky, J.2
  • 13
    • 51649104351 scopus 로고    scopus 로고
    • Quantitative cerebrovascular reserve measured by acetazolamide-challenged dynamic CT perfusion in ischemic adult moyamoya disease: initial experience with angiographic correlation
    • Kang KH, Kim HS, Kim SY. Quantitative cerebrovascular reserve measured by acetazolamide-challenged dynamic CT perfusion in ischemic adult moyamoya disease: initial experience with angiographic correlation. Am J Neuroradiol. 2008; 29(8): 1487-93.
    • (2008) Am J Neuroradiol , vol.29 , Issue.8 , pp. 1487-1493
    • Kang, K.H.1    Kim, H.S.2    Kim, S.Y.3
  • 14
    • 34447505077 scopus 로고    scopus 로고
    • Imaging after brain injury
    • Coles JP. Imaging after brain injury. Br J Anaesth. 2007; 99(1): 49-60.
    • (2007) Br J Anaesth , vol.99 , Issue.1 , pp. 49-60
    • Coles, J.P.1
  • 15
    • 51449123139 scopus 로고    scopus 로고
    • Perfusion CT compared to H(2) (15)O/O (15)O PET in patients with chronic cervical carotid artery occlusion
    • Kamath A, Smith WS, Powers WJ, Cianfoni A, Chien JD, Videen T, et al. Perfusion CT compared to H(2) (15)O/O (15)O PET in patients with chronic cervical carotid artery occlusion. Neuroradiol. 2008; 50(9): 745-51.
    • (2008) Neuroradiol , vol.50 , Issue.9 , pp. 745-751
    • Kamath, A.1    Smith, W.S.2    Powers, W.J.3    Cianfoni, A.4    Chien, J.D.5    Videen, T.6
  • 16
    • 0037344519 scopus 로고    scopus 로고
    • Quantitative cerebral blood flow measurement with dynamic perfusion CT using the vascular-pixel elimination method: comparison with H2(15)O positron emission tomography
    • Kudo K, Terae S, Katoh C, Oka M, Shiga T, Tamaki N, et al. Quantitative cerebral blood flow measurement with dynamic perfusion CT using the vascular-pixel elimination method: comparison with H2(15)O positron emission tomography. Am J Neuroradiol. 2003; 24(3): 419-26.
    • (2003) Am J Neuroradiol , vol.24 , Issue.3 , pp. 419-426
    • Kudo, K.1    Terae, S.2    Katoh, C.3    Oka, M.4    Shiga, T.5    Tamaki, N.6
  • 17
    • 65249107701 scopus 로고    scopus 로고
    • Perfusion MRI (tmax and MTT) correlation with xenon CT cerebral blood flow in stroke patients
    • Olivot JM, Mlynash M, Zaharchuk G, Straka M, Bammer R, Schwartz N, et al. Perfusion MRI (tmax and MTT) correlation with xenon CT cerebral blood flow in stroke patients. Neurol. 2009; 72(13): 1140-5.
    • (2009) Neurol , vol.72 , Issue.13 , pp. 1140-1145
    • Olivot, J.M.1    Mlynash, M.2    Zaharchuk, G.3    Straka, M.4    Bammer, R.5    Schwartz, N.6
  • 18
    • 15744389866 scopus 로고    scopus 로고
    • Comparison of cerebral blood flow between perfusion computed tomography and xenon-enhanced computed tomography for normal subjects: territorial analysis
    • Sase S, Honda M, Machida K, Seiki Y. Comparison of cerebral blood flow between perfusion computed tomography and xenon-enhanced computed tomography for normal subjects: territorial analysis. J Comput Assist Tomogr. 2005; 29(2): 270-7.
    • (2005) J Comput Assist Tomogr , vol.29 , Issue.2 , pp. 270-277
    • Sase, S.1    Honda, M.2    Machida, K.3    Seiki, Y.4
  • 19
    • 65949115728 scopus 로고    scopus 로고
    • The acetazolamide challenge: techniques and applications in the evaluation of chronic cerebral ischemia
    • Vagal AS, Leach JL, Fernandez-Ulloa M, Zuccarello M. The acetazolamide challenge: techniques and applications in the evaluation of chronic cerebral ischemia. Am J Neuroradiol. 2009; 30(5): 876-84.
    • (2009) Am J Neuroradiol , vol.30 , Issue.5 , pp. 876-884
    • Vagal, A.S.1    Leach, J.L.2    Fernandez-Ulloa, M.3    Zuccarello, M.4
  • 20
    • 38649106740 scopus 로고    scopus 로고
    • Perfusion-CT for early assessment of traumatic cerebral contusions
    • Soustiel JF, Mahamid E, Goldsher D, Zaaroor M. Perfusion-CT for early assessment of traumatic cerebral contusions. Neuroradiol. 2008; 50(2): 189-96.
    • (2008) Neuroradiol , vol.50 , Issue.2 , pp. 189-196
    • Soustiel, J.F.1    Mahamid, E.2    Goldsher, D.3    Zaaroor, M.4
  • 21
    • 33744808522 scopus 로고    scopus 로고
    • Stroke imaging with xenon-CT
    • Mullins ME. Stroke imaging with xenon-CT. Semin Ultrasound CT MR. 2006; 27(3): 219-20.
    • (2006) Semin Ultrasound CT MR , vol.27 , Issue.3 , pp. 219-220
    • Mullins, M.E.1
  • 22
    • 34250669621 scopus 로고    scopus 로고
    • Measurement of cerebral perfusion with arterial spin labeling: part 2. Applications
    • Brown GG, Clark C, Liu TT. Measurement of cerebral perfusion with arterial spin labeling: part 2. Applications. J Int Neuropsychol Soc. 2007; 13(3): 526-38.
    • (2007) J Int Neuropsychol Soc , vol.13 , Issue.3 , pp. 526-538
    • Brown, G.G.1    Clark, C.2    Liu, T.T.3
  • 23
    • 41949139506 scopus 로고    scopus 로고
    • Validation study of a pulsed arterial spin labeling technique by comparison to perfusion computed tomography
    • Koziak AM, Winter J, Lee TY, Thompson RT, St Lawrence KS. Validation study of a pulsed arterial spin labeling technique by comparison to perfusion computed tomography. Magn Reson Imaging. 2008; 26(4): 543-53.
    • (2008) Magn Reson Imaging , vol.26 , Issue.4 , pp. 543-553
    • Koziak, A.M.1    Winter, J.2    Lee, T.Y.3    Thompson, R.T.4    St Lawrence, K.S.5
  • 24
    • 35648997907 scopus 로고    scopus 로고
    • Improved arterial spin labeling method: applications for measurements of cerebral blood flow in human brain at high magnetic field MRI
    • Jahng GH, Weiner MW, Schuff N. Improved arterial spin labeling method: applications for measurements of cerebral blood flow in human brain at high magnetic field MRI. Med Phys. 2007; 34(11): 4519-25.
    • (2007) Med Phys , vol.34 , Issue.11 , pp. 4519-4525
    • Jahng, G.H.1    Weiner, M.W.2    Schuff, N.3
  • 25
    • 67650033400 scopus 로고    scopus 로고
    • Absolute quantification of cerebral blood flow in neurologically normal volunteers: dynamic-susceptibility contrast MRI-perfusion compared with computed tomography (CT)-perfusion
    • Ziegelitz D, Starck G, Mikkelsen IK, Tullberg M, Edsbagge M, Wikkelso C, et al. Absolute quantification of cerebral blood flow in neurologically normal volunteers: dynamic-susceptibility contrast MRI-perfusion compared with computed tomography (CT)-perfusion. Magn Reson Med. 2009; 62(1): 56-65.
    • (2009) Magn Reson Med , vol.62 , Issue.1 , pp. 56-65
    • Ziegelitz, D.1    Starck, G.2    Mikkelsen, I.K.3    Tullberg, M.4    Edsbagge, M.5    Wikkelso, C.6
  • 26
    • 58249101218 scopus 로고    scopus 로고
    • Tracer delay-insensitive algorithm can improve reliability of CT perfusion imaging for cerebrovascular steno-occlusive disease: comparison with quantitative single-photon emission CT
    • Sasaki M, Kudo K, Ogasawara K, Fujiwara S. Tracer delay-insensitive algorithm can improve reliability of CT perfusion imaging for cerebrovascular steno-occlusive disease: comparison with quantitative single-photon emission CT. Am J Neuroradiol. 2009; 30(1): 188-93.
    • (2009) Am J Neuroradiol , vol.30 , Issue.1 , pp. 188-193
    • Sasaki, M.1    Kudo, K.2    Ogasawara, K.3    Fujiwara, S.4
  • 27
    • 67650070664 scopus 로고    scopus 로고
    • The performance of MRI-based cerebral blood flow measurements in acute and sub acute stroke compared with 15O-water positron emission tomography: identification of penumbral flow
    • Zaro-Weber O, Moeller-Hartmann W, Heiss WD, Sobesky J. The performance of MRI-based cerebral blood flow measurements in acute and sub acute stroke compared with 15O-water positron emission tomography: identification of penumbral flow. Stroke. 2009; 40(7): 2413-21.
    • (2009) Stroke , vol.40 , Issue.7 , pp. 2413-2421
    • Zaro-Weber, O.1    Moeller-Hartmann, W.2    Heiss, W.D.3    Sobesky, J.4
  • 28
    • 39549111237 scopus 로고    scopus 로고
    • Brain perfusion territory imaging: methods and clinical applications of selective arterial spin-labeling MR imaging
    • van Laar PJ, van der Grond J, Hendrikse J. Brain perfusion territory imaging: methods and clinical applications of selective arterial spin-labeling MR imaging. Radiol. 2008; 246(2): 354-64.
    • (2008) Radiol , vol.246 , Issue.2 , pp. 354-364
    • van Laar, P.J.1    van der Grond, J.2    Hendrikse, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.