메뉴 건너뛰기




Volumn 11, Issue 10 SUPPL.1, 2010, Pages

Infectious complications in patients with devices: Lead extraction;Complicanze infettive nel paziente portatore di dispositivi: L'estrazione di elettrocateteri

Author keywords

Lead extraction; Lead infection

Indexed keywords

ADULT; ARTIFICIAL HEART PACEMAKER; BACTEREMIA; BACTERIAL ENDOCARDITIS; CATHETER INFECTION; CATHETERIZATION; DEVICE REMOVAL; ECHOCARDIOGRAPHY; HUMAN; INDWELLING CATHETER; INFECTION; META ANALYSIS (TOPIC); METHODOLOGY; MICROBIOLOGY; PRACTICE GUIDELINE; REVIEW; STAPHYLOCOCCUS INFECTION; UNITED KINGDOM; UNITED STATES;

EID: 79955700153     PISSN: 18276806     EISSN: 19726481     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (30)
  • 1
    • 0033770747 scopus 로고    scopus 로고
    • Diagnosis and management of infections involving implantable electrophysiologic cardiac devices
    • Chua JD, Wilkoff BL, Lee I, Juratli N, Longworth DL, Gordon SM. Diagnosis and management of infections involving implantable electrophysiologic cardiac devices. Ann Intern Med 2000; 133: 604-8.
    • (2000) Ann Intern Med , vol.133 , pp. 604-608
    • Chua, J.D.1    Wilkoff, B.L.2    Lee, I.3    Juratli, N.4    Longworth, D.L.5    Gordon, S.M.6
  • 2
    • 0142095371 scopus 로고    scopus 로고
    • Pacemaker and defibrillator infections
    • Waldvolgel F, Bisno AL, eds. Washington, DC: American Society for Microbiology Press
    • Eggimann P, Waldvogel F. Pacemaker and defibrillator infections. In: Waldvolgel F, Bisno AL, eds. Infections associated with indwelling medical devices. Washington, DC: American Society for Microbiology Press, 2000: 247.
    • (2000) Infections Associated with Indwelling Medical Devices , vol.247
    • Eggimann, P.1    Waldvogel, F.2
  • 4
    • 17344374262 scopus 로고    scopus 로고
    • Infections associated with implantable cardioverter defibrillators placed transvenously and via thoracotomies: Epidemiology, infection control, and management
    • Lai KK, Fontecchio SA. Infections associated with implantable cardioverter defibrillators placed transvenously and via thoracotomies: epidemiology, infection control, and management. Clin Infect Dis 1998; 27: 265-9.
    • (1998) Clin Infect Dis , vol.27 , pp. 265-269
    • Lai, K.K.1    Fontecchio, S.A.2
  • 5
    • 0028200522 scopus 로고
    • Nonvalvular infections of the cardiovascular system
    • Kearney RA, Eisen HJ, Wolf JE. Nonvalvular infections of the cardiovascular system. Ann Intern Med 1994; 121: 219-30.
    • (1994) Ann Intern Med , vol.121 , pp. 219-230
    • Kearney, R.A.1    Eisen, H.J.2    Wolf, J.E.3
  • 6
    • 0022342981 scopus 로고
    • Pacemaker infections. A 2-year follow-up of antibiotic prophylaxis
    • Bluhm GL. Pacemaker infections. A 2-year follow-up of antibiotic prophylaxis. Scand J Thorac Cardiovasc Surg 1985; 19: 231-5.
    • (1985) Scand J Thorac Cardiovasc Surg , vol.19 , pp. 231-235
    • Bluhm, G.L.1
  • 8
    • 0023181435 scopus 로고
    • Complications of permanent transvenous cardiac pacing: A 14-year review of all transvenous pacemakers inserted at one community hospital
    • Hill PE. Complications of permanent transvenous cardiac pacing: a 14-year review of all transvenous pacemakers inserted at one community hospital. Pacing Clin Electrophysiol 1987; 10 (3 Pt 1): 564-70.
    • (1987) Pacing Clin Electrophysiol , vol.10 , Issue.3 PART 1 , pp. 564-570
    • Hill, P.E.1
  • 9
    • 0031908177 scopus 로고    scopus 로고
    • Infections with nonthoracotomy implantable cardioverter defibrillators: Can these be prevented? Endotak Lead Clinical Investigators
    • Smith PN, Vidaillet HJ, Hayes JJ, et al. Infections with nonthoracotomy implantable cardioverter defibrillators: can these be prevented? Endotak Lead Clinical Investigators. Pacing Clin Electrophysiol 1998; 21 (1 Pt 1): 42-55.
    • (1998) Pacing Clin Electrophysiol , vol.21 , Issue.1 PART 1 , pp. 42-55
    • Smith, P.N.1    Vidaillet, H.J.2    Hayes, J.J.3
  • 10
    • 0021776243 scopus 로고
    • Pacemaker infections. A clinical study with special reference to prophylactic use of some isoxazolyl penicillins
    • Bluhm G. Pacemaker infections. A clinical study with special reference to prophylactic use of some isoxazolyl penicillins. Acta Med Scand Suppl 1985; 699: 1-62.
    • (1985) Acta Med Scand Suppl , vol.699 , pp. 1-62
    • Bluhm, G.1
  • 11
    • 0038270017 scopus 로고    scopus 로고
    • Pacemaker lead infection in young patients
    • Klug D, Vaksmann G, Jarwé M, et al. Pacemaker lead infection in young patients. Pacing Clin Electrophysiol 2003; 26 (7 Pt 1): 1489-93.
    • (2003) Pacing Clin Electrophysiol , vol.26 , Issue.7 PART 1 , pp. 1489-1493
    • Klug, D.1    Vaksmann, G.2    Jarwé, M.3
  • 12
    • 0032510664 scopus 로고    scopus 로고
    • Antibiotic prophylaxis for permanent pacemaker implantation: A meta-analysis
    • Da Costa A, Kirkorian G, Cucherat M, et al. Antibiotic prophylaxis for permanent pacemaker implantation: a meta-analysis. Circulation 1998; 97: 1796-801.
    • (1998) Circulation , vol.97 , pp. 1796-1801
    • Da Costa, A.1    Kirkorian, G.2    Cucherat, M.3
  • 13
    • 18244420080 scopus 로고    scopus 로고
    • Pacemaker infective endocarditis
    • Cacoub P, Leprince P, Nataf P, et al. Pacemaker infective endocarditis. Am J Cardiol 1998; 82: 480-4.
    • (1998) Am J Cardiol , vol.82 , pp. 480-484
    • Cacoub, P.1    Leprince, P.2    Nataf, P.3
  • 14
    • 0028027752 scopus 로고
    • Pacemaker endocarditis. Report of 44 cases and review of the literature
    • Arber N, Pras E, Copperman Y, et al. Pacemaker endocarditis. Report of 44 cases and review of the literature. Medicine 1994; 73: 299-305.
    • (1994) Medicine , vol.73 , pp. 299-305
    • Arber, N.1    Pras, E.2    Copperman, Y.3
  • 15
    • 0345131669 scopus 로고    scopus 로고
    • Role of the preaxillary flora in pacemaker infections: A prospective study
    • Da Costa A, Lelièvre H, Kirkorian G, et al. Role of the preaxillary flora in pacemaker infections: a prospective study. Circulation 1998; 97: 1791-5.
    • (1998) Circulation , vol.97 , pp. 1791-1795
    • Da Costa, A.1    Lelièvre, H.2    Kirkorian, G.3
  • 16
    • 0035964388 scopus 로고    scopus 로고
    • Staphylococcus aureus bacteremia in patients with permanent pacemakers or implantable cardioverter-defibrillators
    • Chamis AL, Peterson GE, Cabell CH, et al. Staphylococcus aureus bacteremia in patients with permanent pacemakers or implantable cardioverter-defibrillators. Circulation 2001; 104: 1029-33.
    • (2001) Circulation , vol.104 , pp. 1029-1033
    • Chamis, A.L.1    Peterson, G.E.2    Cabell, C.H.3
  • 18
    • 0020024929 scopus 로고
    • Late unheralded pacemaker pocket infection due to Staphylococcus epidermidis: A new clinical entity
    • Wohl B, Peters RW, Carliner N, Plotnick G, Fisher M. Late unheralded pacemaker pocket infection due to Staphylococcus epidermidis: a new clinical entity. Pacing Clin Electrophysiol 1982; 5: 190-5.
    • (1982) Pacing Clin Electrophysiol , vol.5 , pp. 190-195
    • Wohl, B.1    Peters, R.W.2    Carliner, N.3    Plotnick, G.4    Fisher, M.5
  • 19
    • 0030966399 scopus 로고    scopus 로고
    • Systemic infection related to endocarditis on pacemaker leads: Clinical presentation and management
    • Klug D, Lacroix D, Savoye C, et al. Systemic infection related to endocarditis on pacemaker leads: clinical presentation and management. Circulation 1997; 95: 2098-107.
    • (1997) Circulation , vol.95 , pp. 2098-2107
    • Klug, D.1    Lacroix, D.2    Savoye, C.3
  • 20
    • 0028275834 scopus 로고
    • Usefulness of transesophageal echocardiography for diagnosis of infected trans- venous permanent pacemakers
    • Vilacosta I, Sarria C, San Roman JA, et al. Usefulness of transesophageal echocardiography for diagnosis of infected trans- venous permanent pacemakers. Circulation 1994; 89: 2684-7.
    • (1994) Circulation , vol.89 , pp. 2684-2687
    • Vilacosta, I.1    Sarria, C.2    San Roman, J.A.3
  • 22
    • 0001635323 scopus 로고    scopus 로고
    • Recommendations for extraction of chronically implanted transvenous pacing and defibrillation leads: Indications, facilities, training
    • North American Society of Pacing and Electrophysiology Lead Extraction Conference Faculty
    • Love CJ, Wilkoff BL, Byrd CL, et al. Recommendations for extraction of chronically implanted transvenous pacing and defibrillation leads: indications, facilities, training. North American Society of Pacing and Electrophysiology Lead Extraction Conference Faculty. Pacing Clin Electrophysiol 2000; 23 (4 Pt 1): 544-51.
    • (2000) Pacing Clin Electrophysiol , vol.23 , Issue.4 PART 1 , pp. 544-551
    • Love, C.J.1    Wilkoff, B.L.2    Byrd, C.L.3
  • 23
    • 67549100824 scopus 로고    scopus 로고
    • Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management
    • Wilkoff BL, Love CJ, Byrd CL, et al. Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management. Heart Rhythm 2009; 6: 1085-104.
    • (2009) Heart Rhythm , vol.6 , pp. 1085-1104
    • Wilkoff, B.L.1    Love, C.J.2    Byrd, C.L.3
  • 24
    • 0036090518 scopus 로고    scopus 로고
    • Clinical study of the laser sheath for lead extraction: The total experience in the United States
    • Byrd CL, Wilkoff BL, Love CJ, Sellers TD, Reiser C. Clinical study of the laser sheath for lead extraction: the total experience in the United States. Pacing Clin Electrophysiol 2002; 25: 804-8.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 804-808
    • Byrd, C.L.1    Wilkoff, B.L.2    Love, C.J.3    Sellers, T.D.4    Reiser, C.5
  • 26
    • 0033133418 scopus 로고    scopus 로고
    • Pacemaker lead extraction with the laser sheath: Results of the pacing lead extraction with the excimer sheath (PLEXES) trial
    • Wilkoff BL, Byrd CL, Love CJ, et al. Pacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial. J Am Coll Cardiol 1999; 33: 1671-6.
    • (1999) J Am Coll Cardiol , vol.33 , pp. 1671-1676
    • Wilkoff, B.L.1    Byrd, C.L.2    Love, C.J.3
  • 27
    • 0031881567 scopus 로고    scopus 로고
    • First European experience using excimer laser extraction of permanent pacemaker leads
    • Kennergren C. First European experience using excimer laser extraction of permanent pacemaker leads. Pacing Clin Electrophysiol 1998; 21 (1 Pt 2): 268-70.
    • (1998) Pacing Clin Electrophysiol , vol.21 , Issue.1 PART 2 , pp. 268-270
    • Kennergren, C.1
  • 28
    • 0013607943 scopus 로고    scopus 로고
    • Lead extraction: Ten-year experience [abstract]
    • Byrd CL. Lead extraction: ten-year experience [abstract]. Pacing Clin Electrophysiol 1997; 20: 1110.
    • (1997) Pacing Clin Electrophysiol , vol.20 , pp. 1110
    • Byrd, C.L.1
  • 29
    • 33845615899 scopus 로고    scopus 로고
    • Laser assistance for extraction of chronically implanted endocardial leads infectious versus noninfectious indications
    • Gaynor SL, Zierer A, Lawton JS, Gleva MJ, Damiano RJ Jr, Moon MR. Laser assistance for extraction of chronically implanted endocardial leads: infectious versus noninfectious indications. Pacing Clin Electrophysiol 2006; 29: 1352-8.
    • (2006) Pacing Clin Electrophysiol , vol.29 , pp. 1352-1358
    • Gaynor, S.L.1    Zierer, A.2    Lawton, J.S.3    Gleva, M.J.4    Damiano, R.J.5    Moon Jr., M.R.6
  • 30
    • 33847384171 scopus 로고    scopus 로고
    • Laser lead extraction: Predictors of success and complications
    • Roux JF, Page P, Dubuc M, et al. Laser lead extraction: predictors of success and complications. Pacing Clin Electrophysiol 2007; 30: 214-20.
    • (2007) Pacing Clin Electrophysiol , vol.30 , pp. 214-220
    • Roux, J.F.1    Page, P.2    Dubuc, M.3