메뉴 건너뛰기




Volumn 176, Issue 2, 2011, Pages 22-30

A study on condition assessment method of gas-insulated switchgear. part II. influence of moisture in the SF6, detection of a partial discharge on a spacer, repetition discharge and overheating by incomplete contact

Author keywords

condition based maintenance; diagnosis method; gas analysis; gas insulated switchgear; life extension

Indexed keywords

CONDITION BASED MAINTENANCE; DIAGNOSIS METHODS; GAS ANALYSIS; GAS-INSULATED SWITCHGEAR; LIFE EXTENSION;

EID: 79955460758     PISSN: 04247760     EISSN: 15206416     Source Type: Journal    
DOI: 10.1002/eej.21108     Document Type: Article
Times cited : (21)

References (14)
  • 1
    • 79955366122 scopus 로고    scopus 로고
    • Rationalization of inspection of transformation facilities
    • Rationalization of inspection of transformation facilities. ETRA 2000; 56 (2).
    • (2000) ETRA , vol.56 , Issue.2
  • 2
    • 79955414157 scopus 로고    scopus 로고
    • Transformation facilities of 21st century. from substations to multistations
    • Transformation facilities of 21st century. From substations to multistations. ETRA 2002; 58 (2).
    • (2002) ETRA , vol.58 , Issue.2
  • 3
    • 79955425443 scopus 로고    scopus 로고
    • IT in operation and maintenance of power equipment. Present state and future trends
    • IT in operation and maintenance of power equipment. Present state and future trends. ETRA 2003; 58 (5).
    • (2003) ETRA , vol.58 , Issue.5
  • 4
    • 79955421279 scopus 로고    scopus 로고
    • Specifications of gas insulated switchgear
    • Specifications of gas insulated switchgear. ETRA 1996; 52 (1).
    • (1996) ETRA , vol.52 , Issue.1
  • 7
    • 33846230482 scopus 로고    scopus 로고
    • Study of state diagnosis method of gas-insulated switchgear. High sensitivity detection method of partial discharge by decomposition gas accumulation
    • (in Japanese)
    • Shinkai H, Goshima H, Yashima M., Study of state diagnosis method of gas-insulated switchgear. High sensitivity detection method of partial discharge by decomposition gas accumulation. IEEJ Trans PE 2007; 127: 231-239. (in Japanese)
    • (2007) IEEJ Trans PE , vol.127 , pp. 231-239
    • Shinkai, H.1    Goshima, H.2    Yashima, M.3
  • 8
    • 79955434102 scopus 로고    scopus 로고
    • 6 gas in power applications
    • 6 gas in power applications. ETRA 1998; 54 (3).
    • (1998) ETRA , vol.54 , Issue.3
  • 9
    • 79955420263 scopus 로고    scopus 로고
    • Improvement of maintenance of sealed transformation facilities
    • Improvement of maintenance of sealed transformation facilities. ETRA 2006; 61 (3).
    • (2006) ETRA , vol.61 , Issue.3
  • 10
    • 79955433166 scopus 로고    scopus 로고
    • Environment adaptability and safety of gas insulated switchgear. IEEJ Tech Rep No 852, 2001
    • Environment adaptability and safety of gas insulated switchgear. IEEJ Tech Rep No 852, 2001.
  • 11
    • 79955396605 scopus 로고    scopus 로고
    • Toray Research Center, TEPCO, CRIEPI Japan Patent 3318473
    • 6 gas. Japan Patent 3318473, 2007.
    • (2007) 6 Gas
  • 14
    • 85016537208 scopus 로고
    • Thermal characteristics of sulfur hexafluoride
    • (in Japanese)
    • Hirooka K, Shirai M., Thermal characteristics of sulfur hexafluoride. Chem Soc Jpn 1980; 2: 165-169. (in Japanese)
    • (1980) Chem Soc Jpn , vol.2 , pp. 165-169
    • Hirooka, K.1    Shirai, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.