메뉴 건너뛰기




Volumn 18, Issue 2, 2011, Pages 243-249

Feasibility and safety of remote endovascular catheter navigation in a porcine model

Author keywords

Catheter; Dissection; Intima; Remote catheter navigation; Robotics; Thrombus; Vascular injury

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTERY INJURY; ARTERY INTIMA; ARTERY THROMBOSIS; ARTICLE; BLEEDING; BLOOD VESSEL CATHETERIZATION; DEVICE SAFETY; EQUIPMENT DESIGN; FEASIBILITY STUDY; FEMALE; FEMORAL ARTERY; ILIAC ARTERY; INFLAMMATION; INTRAVASCULAR CATHETER; NONHUMAN; PRIORITY JOURNAL; RENAL ARTERY; ROBOTICS; SUPERIOR MESENTERIC ARTERY; SWINE; TUNICA MEDIA;

EID: 79955456341     PISSN: 15266028     EISSN: 15451550     Source Type: Journal    
DOI: 10.1583/10-3324R.1     Document Type: Article
Times cited : (51)

References (6)
  • 1
    • 40349095113 scopus 로고    scopus 로고
    • Experience of robotic catheter ablation in humans using a novel remotely steerable catheter sheath
    • Kanagaratnam P, Koa-Wing M, Wallace DT, et al. Experience of robotic catheter ablation in humans using a novel remotely steerable catheter sheath. J Interv Card Electrophysiol. 2008;21:19-26.
    • (2008) J Interv Card Electrophysiol , vol.21 , pp. 19-26
    • Kanagaratnam, P.1    Koa-Wing, M.2    Wallace, D.T.3
  • 2
    • 44949220178 scopus 로고    scopus 로고
    • Atrial fibrillation ablation using a robotic catheter remote control system: Initial human experience and long term follow-up results
    • Saliba W, Reddy VY, Wazni O, et al. Atrial fibrillation ablation using a robotic catheter remote control system: initial human experience and long term follow-up results. J Am Coll Cardiol. 2008;51:2407-2422.
    • (2008) J Am Coll Cardiol , vol.51 , pp. 2407-2422
    • Saliba, W.1    Reddy, V.Y.2    Wazni, O.3
  • 3
    • 77949882967 scopus 로고    scopus 로고
    • The role of robotic endovascular catheters in fenestrated stent grafting
    • Riga CV, Cheshire NJ, Hamady MS, et al. The role of robotic endovascular catheters in fenestrated stent grafting. J Vasc Surg. 2010;51:810-820.
    • (2010) J Vasc Surg , vol.51 , pp. 810-820
    • Riga, C.V.1    Cheshire, N.J.2    Hamady, M.S.3
  • 4
    • 67349226455 scopus 로고    scopus 로고
    • Robot-assisted antegrade in-situ fenestrated stent grafting
    • Riga CV, Bicknell CD, Wallace D, et al. Robot-assisted antegrade in-situ fenestrated stent grafting. Cardiovasc Intervent Radiol. 2009;32:522-524.
    • (2009) Cardiovasc Intervent Radiol , vol.32 , pp. 522-524
    • Riga, C.V.1    Bicknell, C.D.2    Wallace, D.3
  • 5
    • 67249136029 scopus 로고    scopus 로고
    • Initial clinical application of a robotically steerable catheter system in endovascular aneurysm repair
    • Riga C, Bicknell C, Cheshire N, et al. Initial clinical application of a robotically steerable catheter system in endovascular aneurysm repair. J Endovasc Ther. 2009;16:149-153.
    • (2009) J Endovasc Ther , vol.16 , pp. 149-153
    • Riga, C.1    Bicknell, C.2    Cheshire, N.3
  • 6
    • 77958602939 scopus 로고    scopus 로고
    • Robot-assisted stenting of a high-grade anastomotic pulmonary artery stenosis following single lung transplantation
    • Lumsden AB, Anaya-Ayala JE, Birnbaum I. Robot-assisted stenting of a high-grade anastomotic pulmonary artery stenosis following single lung transplantation. J Endovasc Ther. 2010;17:612-616.
    • (2010) J Endovasc Ther , vol.17 , pp. 612-616
    • Lumsden, A.B.1    Anaya-Ayala, J.E.2    Birnbaum, I.3