메뉴 건너뛰기




Volumn 10, Issue 3, 2011, Pages 232-241

Measurement of dose perturbation around shielded ovoids in high-dose-rate brachytherapy

Author keywords

High dose rate brachytherapy; Shielded Fletcher Suit Delclos applicator

Indexed keywords

CHROMIUM 51; TUNGSTEN;

EID: 79955135214     PISSN: 15384721     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.brachy.2010.08.008     Document Type: Article
Times cited : (9)

References (23)
  • 1
    • 0021848974 scopus 로고
    • Computation of radiation dose distributions for shielded cervical applicators
    • Mohan R., Ding I.Y., Toraskar J., et al. Computation of radiation dose distributions for shielded cervical applicators. Int J Radiat Oncol Biol Phys 1985, 11:823-830.
    • (1985) Int J Radiat Oncol Biol Phys , vol.11 , pp. 823-830
    • Mohan, R.1    Ding, I.Y.2    Toraskar, J.3
  • 2
    • 0025334388 scopus 로고
    • Dose calculations about gynecological colpostats
    • Williamson J.F. Dose calculations about gynecological colpostats. Int J Radiat Oncol Biol Phys 1990, 19:167-178.
    • (1990) Int J Radiat Oncol Biol Phys , vol.19 , pp. 167-178
    • Williamson, J.F.1
  • 3
    • 0030876356 scopus 로고    scopus 로고
    • An analysis of the effect of ovoid shields in a selectron-LDR cervical applicator on dose distribution in rectum and bladder
    • Steggerda M.J., Moonen L.M.F., Damen E.M.F., et al. An analysis of the effect of ovoid shields in a selectron-LDR cervical applicator on dose distribution in rectum and bladder. Int J Radiat Oncol Biol Phys 1997, 39:237-245.
    • (1997) Int J Radiat Oncol Biol Phys , vol.39 , pp. 237-245
    • Steggerda, M.J.1    Moonen, L.M.F.2    Damen, E.M.F.3
  • 4
    • 22544462191 scopus 로고    scopus 로고
    • Comparison of Monte Carlo calculations around a Fletcher Suit Delclos ovoid with radiochromic film and normoxic polymer gel dosimetry
    • Gifford K.A., Horton J.L., Jackson E.F., et al. Comparison of Monte Carlo calculations around a Fletcher Suit Delclos ovoid with radiochromic film and normoxic polymer gel dosimetry. Med Phys 2005, 32:2288-2294.
    • (2005) Med Phys , vol.32 , pp. 2288-2294
    • Gifford, K.A.1    Horton, J.L.2    Jackson, E.F.3
  • 5
    • 0032910742 scopus 로고    scopus 로고
    • In-vivo rectal dose measurements with diodes to avoid misadministrations during intracavitary high dose rate brachytherapy for carcinoma of the cervix
    • Alecu R., Alecu M. In-vivo rectal dose measurements with diodes to avoid misadministrations during intracavitary high dose rate brachytherapy for carcinoma of the cervix. Med Phys 1999, 26:768-770.
    • (1999) Med Phys , vol.26 , pp. 768-770
    • Alecu, R.1    Alecu, M.2
  • 6
    • 24944557163 scopus 로고    scopus 로고
    • A three-dimensional computed tomography-assisted Monte Carlo evaluation of ovoid shielding on the dose to the rectum and bladder in intracavitary radiotherapy for cervical cancer
    • Gifford K.A., Horton J.L., Pelloski C.E., et al. A three-dimensional computed tomography-assisted Monte Carlo evaluation of ovoid shielding on the dose to the rectum and bladder in intracavitary radiotherapy for cervical cancer. Int J Radiat Oncol Biol Phys 2005, 63:615-621.
    • (2005) Int J Radiat Oncol Biol Phys , vol.63 , pp. 615-621
    • Gifford, K.A.1    Horton, J.L.2    Pelloski, C.E.3
  • 7
    • 0008796868 scopus 로고    scopus 로고
    • Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55
    • Niroomand-Rad A., Blackwell C.R., Coursey B.M., et al. Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55. Med Phys 1998, 25:2093-2115.
    • (1998) Med Phys , vol.25 , pp. 2093-2115
    • Niroomand-Rad, A.1    Blackwell, C.R.2    Coursey, B.M.3
  • 8
    • 33646461862 scopus 로고    scopus 로고
    • Evaluation of GafChromic EBT prototype B for external beam dose verification
    • Todorovic R., Fishcher M., Cremers F., et al. Evaluation of GafChromic EBT prototype B for external beam dose verification. Med Phys 2006, 33:1321-1328.
    • (2006) Med Phys , vol.33 , pp. 1321-1328
    • Todorovic, R.1    Fishcher, M.2    Cremers, F.3
  • 9
    • 77951797901 scopus 로고    scopus 로고
    • Study of Gafchromic EBT film response over a large dose range
    • Martisíková M., Jäkel O. Study of Gafchromic EBT film response over a large dose range. Phys Med Biol 2010, 21:281-290.
    • (2010) Phys Med Biol , vol.21 , pp. 281-290
    • Martisíková, M.1    Jäkel, O.2
  • 10
    • 75749154506 scopus 로고    scopus 로고
    • Investigation of energy dependence of EBT and EBT-2 gafchromic film
    • Lindsay P., Rink A., Ruschin M., et al. Investigation of energy dependence of EBT and EBT-2 gafchromic film. Med Phys 2010, 37:571-576.
    • (2010) Med Phys , vol.37 , pp. 571-576
    • Lindsay, P.1    Rink, A.2    Ruschin, M.3
  • 11
    • 79955148304 scopus 로고    scopus 로고
    • Gafchromic® EBT: self-developing film for radiotherapy dosimetry. Wayne, NJ: International Specialty Products.
    • Gafchromic® EBT: self-developing film for radiotherapy dosimetry. Wayne, NJ: International Specialty Products 2006. p. 1-8.
    • (2006) , pp. 1-8
  • 12
    • 16344388628 scopus 로고    scopus 로고
    • Evaluation of IOHDR underdosage resulting from lack of backscatter during treatment
    • Raina S., Avadhani J.S., Oh M., et al. Evaluation of IOHDR underdosage resulting from lack of backscatter during treatment. Int J Radiat Oncol Biol Phys 2005, 61:1582-1586.
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 1582-1586
    • Raina, S.1    Avadhani, J.S.2    Oh, M.3
  • 13
    • 58749111677 scopus 로고    scopus 로고
    • Impact of surface curvature on dose delivery in intraoperative high-dose-rate brachytherapy
    • Oh M., Wang Z., Malhotra H.K., et al. Impact of surface curvature on dose delivery in intraoperative high-dose-rate brachytherapy. Med Dosim 2009, 34:63-74.
    • (2009) Med Dosim , vol.34 , pp. 63-74
    • Oh, M.1    Wang, Z.2    Malhotra, H.K.3
  • 14
    • 38549095480 scopus 로고    scopus 로고
    • Retrospective analysis of dose delivery in intraoperative high dose rate brachytherapy
    • Oh M., Avadhani J.S., Malhotra H.K., et al. Retrospective analysis of dose delivery in intraoperative high dose rate brachytherapy. Radiol Oncol 2007, 41:188-195.
    • (2007) Radiol Oncol , vol.41 , pp. 188-195
    • Oh, M.1    Avadhani, J.S.2    Malhotra, H.K.3
  • 15
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
    • Nath R., Anderson L.L., Luxton G., et al. Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. Med Phys 1995, 22:209-234.
    • (1995) Med Phys , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3
  • 16
    • 0003868944 scopus 로고
    • Charles C Thomas Publisher, Springfield, IL
    • Johns H.E. The Physics of Radiology 1961, Charles C Thomas Publisher, Springfield, IL, p. 699. 2nd Ed.
    • (1961) The Physics of Radiology , pp. 699
    • Johns, H.E.1
  • 17
    • 22544440841 scopus 로고    scopus 로고
    • Precise radiochromic film dosimetry using a flat-bed document scanner
    • Slobodan D., Seuntjens J., Sham Edwin, et al. Precise radiochromic film dosimetry using a flat-bed document scanner. Med Phys 2005, 32:2245-2253.
    • (2005) Med Phys , vol.32 , pp. 2245-2253
    • Slobodan, D.1    Seuntjens, J.2    Sham, E.3
  • 18
    • 0031045089 scopus 로고    scopus 로고
    • Quantitative evaluation of radiochromic film response for two-dimensional dosimetry
    • Zhu Y., Kirov A.S., Mishra V., et al. Quantitative evaluation of radiochromic film response for two-dimensional dosimetry. Med Phys 1997, 24:223-231.
    • (1997) Med Phys , vol.24 , pp. 223-231
    • Zhu, Y.1    Kirov, A.S.2    Mishra, V.3
  • 19
    • 72049127764 scopus 로고    scopus 로고
    • Development of prototype shielded cervical intracavitary brachytherapy applicators compatible with CT and MR imaging
    • Price M.J., Jackson E.F., Gifford K.A., et al. Development of prototype shielded cervical intracavitary brachytherapy applicators compatible with CT and MR imaging. Med Phys 2009, 36:5515-5524.
    • (2009) Med Phys , vol.36 , pp. 5515-5524
    • Price, M.J.1    Jackson, E.F.2    Gifford, K.A.3
  • 20
    • 27944477251 scopus 로고    scopus 로고
    • Monte Carlo calculations of the dose distribution around a commercial gynecologic tandem applicator
    • Gifford K.A., Mourtada F., Cho S.H., et al. Monte Carlo calculations of the dose distribution around a commercial gynecologic tandem applicator. Radiother Oncol 2005, 77:210-215.
    • (2005) Radiother Oncol , vol.77 , pp. 210-215
    • Gifford, K.A.1    Mourtada, F.2    Cho, S.H.3
  • 21
    • 77954253361 scopus 로고    scopus 로고
    • Dose perturbation due to the polysulfone cap surrounding a Fletcher-Williamson colpostat
    • Price M.J., Kry S.F., Eifel P.J., et al. Dose perturbation due to the polysulfone cap surrounding a Fletcher-Williamson colpostat. J Appl Clin Med Phys 2010, 11:68-76.
    • (2010) J Appl Clin Med Phys , vol.11 , pp. 68-76
    • Price, M.J.1    Kry, S.F.2    Eifel, P.J.3
  • 22
    • 67651049790 scopus 로고    scopus 로고
    • A quantitative three-dimensional dose attenuation analysis around Fletcher-Suit-Delclos due to stainless steel tube for high-dose-rate brachytherapy by Monte Carlo calculations
    • Parsai E.I., Zhang Z., Feldmeier J.J. A quantitative three-dimensional dose attenuation analysis around Fletcher-Suit-Delclos due to stainless steel tube for high-dose-rate brachytherapy by Monte Carlo calculations. Brachytherapy 2009, 8:318-323.
    • (2009) Brachytherapy , vol.8 , pp. 318-323
    • Parsai, E.I.1    Zhang, Z.2    Feldmeier, J.J.3
  • 23
    • 44349099242 scopus 로고    scopus 로고
    • Optimization of deterministic transport parameters for the calculation of the dose distribution around a high dose-rate 192Ir brachytherapy source
    • Gifford K.A., Price M.J., Horton J.L., et al. Optimization of deterministic transport parameters for the calculation of the dose distribution around a high dose-rate 192Ir brachytherapy source. Med Phys 2008, 35:2279-2285.
    • (2008) Med Phys , vol.35 , pp. 2279-2285
    • Gifford, K.A.1    Price, M.J.2    Horton, J.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.