A quantitative three-dimensional dose attenuation analysis around Fletcher-Suit-Delclos due to stainless steel tube for high-dose-rate brachytherapy by Monte Carlo calculations
On the validity of the superposition principle in dose calculations for intracavitary implants with shielded vaginal colpostats
Markman J., Williamson J.F., Dempsey J.F., et al. On the validity of the superposition principle in dose calculations for intracavitary implants with shielded vaginal colpostats. Med Phys 28 (2001) 147-155
Measurement and calculation of heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields
Kirov A.S., Williamson J.F., Meigooni A.S., et al. Measurement and calculation of heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields. Med Phys 23 (1996) 911-919
On the determination of the effective transmission factor for stainless steel ovoid shielding segments and estimation of their shielding efficacy for clinical situation
Verellen D., De Neve W., Van den Heuvel F., et al. On the determination of the effective transmission factor for stainless steel ovoid shielding segments and estimation of their shielding efficacy for clinical situation. Med Phys 21 (1994) 1677-1684
Three dimensional quantitative dose reduction analysis in MammoSite balloon by Monte Carlo calculations
Zhang Z.D., Parsai E.I., and Feldmeier J.J. Three dimensional quantitative dose reduction analysis in MammoSite balloon by Monte Carlo calculations. J Appl Clin Med Phys 8 (2007) 139-151
Update of AAPM Task Group No.43 Report: A revised AAPM protocol for brachytherapy dose calculations
Rivard M.J., Coursey B.M., DeWerd L.A., et al. Update of AAPM Task Group No.43 Report: A revised AAPM protocol for brachytherapy dose calculations. Med Phys 31 (2004) 633-674
Briesmeister JF. MCNP-A general Monte Carlo N-particle transport code, version 4C. Los Alamos National Laboratory Report 2000; La-13709-M.
Briesmeister JF. MCNP-A general Monte Carlo N-particle transport code, version 4C. Los Alamos National Laboratory Report 2000; La-13709-M.
10
0029062568
Experimental validation of Monte Carlo dose calculations about a high-intensity Ir-192 source for pulsed dose-rate brachytherapy
Valicenti R.K., Kirov A.S., Meigooni A.S., et al. Experimental validation of Monte Carlo dose calculations about a high-intensity Ir-192 source for pulsed dose-rate brachytherapy. Med Phys 22 (1995) 821-829