메뉴 건너뛰기




Volumn 259, Issue 2, 2011, Pages 550-557

Brain MR imaging at ultra-low radiofrequency power

Author keywords

[No Author keywords available]

Indexed keywords

ABSORPTION; ADULT; AGED; ARTICLE; BRAIN RADIOGRAPHY; COMPARATIVE STUDY; CONTRAST NOISE RATIO; CONTROLLED STUDY; FEMALE; HUMAN; HUMAN EXPERIMENT; IMAGE QUALITY; MALE; MATHEMATICAL PARAMETERS; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RADIOFREQUENCY; SIGNAL NOISE RATIO; STEADY STATE; THREE DIMENSIONAL IMAGING;

EID: 79955046272     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.11092445     Document Type: Article
Times cited : (21)

References (20)
  • 1
    • 0026248451 scopus 로고
    • T2-weighted thin-section imaging with the multislab three-dimensional RARE technique
    • Oshio K , Jolesz FA , Melki PS , Mulkern RV T2-weighted thin-section imaging with the multislab three-dimensional RARE technique J Magn Reson Imaging 1991 ; 1 ( 6 ): 695-700
    • (1991) J Magn Reson Imaging , vol.1 , Issue.6 , pp. 695-700
    • Oshio, K.1    Jolesz, F.A.2    Melki, P.S.3    Mulkern, R.V.4
  • 2
    • 0029884174 scopus 로고    scopus 로고
    • The influence of stimulated echoes on contrast in fast spin-echo imaging
    • DOI 10.1016/0730-725X(95)02110-F
    • Williams CF , Redpath TW , Smith FW The influence of stimulated echoes on contrast in fast spin-echo imaging Magn Reson Imaging 1996 ; 14 ( 4 ): 419-428 (Pubitemid 26195076)
    • (1996) Magnetic Resonance Imaging , vol.14 , Issue.4 , pp. 419-428
    • Williams, C.F.M.1    Redpath, T.W.2    Smith, F.W.3
  • 4
    • 51449085600 scopus 로고    scopus 로고
    • Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo
    • Busse RF , Brau AC , Vu A , et al Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo Magn Reson Med 2008 ; 60 ( 3 ): 640-649
    • (2008) Magn Reson Med , vol.60 , Issue.3 , pp. 640-649
    • Busse, R.F.1    Brau, A.C.2    Vu, A.3
  • 5
    • 0000811634 scopus 로고
    • Multiecho imaging sequences with low refocusing flip angles
    • Hennig J Multiecho imaging sequences with low refocusing flip angles J Magn Reson 1988 ; 78 ( 3 ): 397-407
    • (1988) J Magn Reson , vol.78 , Issue.3 , pp. 397-407
    • Hennig, J.1
  • 6
    • 0347634471 scopus 로고    scopus 로고
    • Calculation of Flip Angles for Echo Trains with Predefined Amplitudes with the Extended Phase Graph (EPG)-Algorithm: Principles and Applications to Hyperecho and TRAPS Sequences
    • DOI 10.1002/mrm.10658
    • Hennig J , Weigel M , Scheffler K Calculation of flip angles for echo trains with predefined amplitudes with the extended phase graph (EPG)-algorithm: Principles and applications to hyperecho and TRAPS sequences Magn Reson Med 2004 ; 51 ( 1 ): 68-80 (Pubitemid 38095704)
    • (2004) Magnetic Resonance in Medicine , vol.51 , Issue.1 , pp. 68-80
    • Hennig, J.1    Weigel, M.2    Scheffler, K.3
  • 7
    • 12244276309 scopus 로고    scopus 로고
    • T2-weighted 3d spin-echo train imaging of the brain at 3 Tesla: Reduced power deposition using low flip-angle refocusing RF pulses [abstr]
    • Berkeley Calif: International Society for Magnetic Resonance in Medicine
    • Mugler J , Wald L , Brookman J T2-weighted 3d spin-echo train imaging of the brain at 3 Tesla: Reduced power deposition using low flip-angle refocusing RF pulses [abstr]. In: Proceedings of the Ninth Meeting of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: International Society for Magnetic Resonance in Medicine, 2001 ; 438.
    • (2001) Proceedings of the Ninth Meeting of the International Society for Magnetic Resonance in Medicine , vol.438
    • Mugler, J.1    Wald, L.2    Brookman, J.3
  • 8
    • 0031022460 scopus 로고    scopus 로고
    • The sensitivity of low flip angle RARE imaging
    • DOI 10.1002/mrm.1910370206
    • Alsop DC The sensitivity of low flip angle RARE imaging Magn Reson Med 1997 ; 37 ( 2 ): 176-184 (Pubitemid 27045388)
    • (1997) Magnetic Resonance in Medicine , vol.37 , Issue.2 , pp. 176-184
    • Alsop, D.C.1
  • 9
    • 67650085835 scopus 로고    scopus 로고
    • Time-efficient fast spin echo imaging at 4.7 T with low refocusing angles
    • Lebel RM , Wilman AH Time-efficient fast spin echo imaging at 4.7 T with low refocusing angles Magn Reson Med 2009 ; 62 ( 1 ): 96-105
    • (2009) Magn Reson Med , vol.62 , Issue.1 , pp. 96-105
    • Lebel, R.M.1    Wilman, A.H.2
  • 10
    • 38949156006 scopus 로고    scopus 로고
    • A method for autocalibrating 2D-accelerated volumetric parallel imaging with clinically practical reconstruction times [abstr]
    • Berkeley Calif: International Society for Magnetic Resonance in Medicine
    • Beatty P , Brau A , Chang S , et al A method for autocalibrating 2D-accelerated volumetric parallel imaging with clinically practical reconstruction times [abstr]. In: Proceedings of the Fifteenth Meeting of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: International Society for Magnetic Resonance in Medicine, 2007 ; 1749.
    • (2007) Proceedings of the Fifteenth Meeting of the International Society for Magnetic Resonance in Medicine , vol.1749
    • Beatty, P.1    Brau, A.2    Chang, S.3
  • 12
    • 53549094426 scopus 로고    scopus 로고
    • Comprehensive quantification of signal-tonoise ratio and g -factor for image-based and k-space-based parallel imaging reconstructions
    • Robson PM , Grant AK , Madhuranthakam AJ , Lattanzi R , Sodickson DK , McKenzie CA Comprehensive quantification of signal-tonoise ratio and g -factor for image-based and k -space-based parallel imaging reconstructions Magn Reson Med 2008 ; 60 ( 4 ): 895-907
    • (2008) Magn Reson Med , vol.60 , Issue.4 , pp. 895-907
    • Robson, P.M.1    Grant, A.K.2    Madhuranthakam, A.J.3    Lattanzi, R.4    Sodickson, D.K.5    McKenzie, C.A.6
  • 13
    • 33845290629 scopus 로고    scopus 로고
    • Variability in RF-induced heating of a deep brain stimulation implant across MR systems
    • DOI 10.1002/jmri.20769
    • Baker KB , Tkach JA , Phillips MD , Rezai AR Variability in RF-induced heating of a deep brain stimulation implant across MR systems J Magn Reson Imaging 2006 ; 24 ( 6 ): 1236-1242 (Pubitemid 44871866)
    • (2006) Journal of Magnetic Resonance Imaging , vol.24 , Issue.6 , pp. 1236-1242
    • Baker, K.B.1    Tkach, J.A.2    Phillips, M.D.3    Rezai, A.R.4
  • 17
    • 67651166625 scopus 로고    scopus 로고
    • Safety of MRI in patients with implanted deep brain stimulation devices
    • Tagliati M , Jankovic J , Pagan F , et al Safety of MRI in patients with implanted deep brain stimulation devices Neuroimage 2009 ; 47 ( Suppl 2 ): T53-T57
    • (2009) Neuroimage , vol.47 , Issue.SUPPL. 2
    • Tagliati, M.1    Jankovic, J.2    Pagan, F.3
  • 19
    • 34548207185 scopus 로고    scopus 로고
    • 3D MRI in multiple sclerosis: A study of three sequences at 3 T
    • DOI 10.1259/bjr/52670770
    • Mills RJ , Young CA , Smith ET 3D MRI in multiple sclerosis: A study of three sequences at 3 T Br J Radiol 2007 ; 80 ( 953 ): 307-320 (Pubitemid 47315844)
    • (2007) British Journal of Radiology , vol.80 , Issue.953 , pp. 307-320
    • Mills, R.J.1    Young, C.A.2    Smith, E.T.S.3
  • 20
    • 73349139471 scopus 로고    scopus 로고
    • PROMO: Real-time prospective motion correction in MRI using image-based tracking
    • White N , Roddey C , Shankaranarayanan A , et al PROMO: Real-time prospective motion correction in MRI using image-based tracking Magn Reson Med 2010 ; 63 ( 1 ): 91-105
    • (2010) Magn Reson Med , vol.63 , Issue.1 , pp. 91-105
    • White, N.1    Roddey, C.2    Shankaranarayanan, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.