Safety of MRI in patients with implanted deep brain stimulation devices

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BRAIN DEPTH STIMULATION; CLINICAL PROTOCOL; HUMAN; IMAGE DISPLAY; MAJOR CLINICAL STUDY; MEDICAL PRACTICE; NEUROIMAGING; NUCLEAR MAGNETIC RESONANCE IMAGING; PARKINSON DISEASE; PATIENT SAFETY; PRIORITY JOURNAL; PULSE GENERATOR; RISK BENEFIT ANALYSIS;

EID: 67651166625     PISSN: 10538119     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2009.04.044     Document Type: Article
Times cited : (102)

References (16)
  • 1
    • 33748374268 scopus 로고    scopus 로고
    • Performing functional magnetic resonance imaging in patients with Parkinson's disease treated with deep brain stimulation
    • Arantes P.R., Cardoso E.F., Barreiros M.A., et al. Performing functional magnetic resonance imaging in patients with Parkinson's disease treated with deep brain stimulation. Mov. Disord. 21 (2006) 1154-1162
    • (2006) Mov. Disord. , vol.21 , pp. 1154-1162
    • Arantes, P.R.1    Cardoso, E.F.2    Barreiros, M.A.3
  • 2
    • 26844503103 scopus 로고    scopus 로고
    • Reduction of magnetic resonance imaging-related heating in deep brain stimulation leads using a lead management device
    • Baker K.B., Tkach J., et al. Reduction of magnetic resonance imaging-related heating in deep brain stimulation leads using a lead management device. Neurosurgery 57 Supp.4 (2005) 392-397
    • (2005) Neurosurgery , vol.57 , Issue.SUPPL.4 , pp. 392-397
    • Baker, K.B.1    Tkach, J.2
  • 3
    • 20344383997 scopus 로고    scopus 로고
    • Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain
    • Bhidayasiri R., and Bronstein J.M. Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain. Magn. Reson. Imaging 23 (2005) 549-555
    • (2005) Magn. Reson. Imaging , vol.23 , pp. 549-555
    • Bhidayasiri, R.1    Bronstein, J.M.2
  • 5
    • 27644509327 scopus 로고    scopus 로고
    • Permanent neurological deficit related to magnetic resonance imaging in a patient with implanted deep brain stimulation electrodes for Parkinson's disease: case report
    • Henderson J.M., Tkach J., Phillips M., Baker K., Shellock F.G., and Rezai A.R. Permanent neurological deficit related to magnetic resonance imaging in a patient with implanted deep brain stimulation electrodes for Parkinson's disease: case report. Neurosurgery 57 (2005) E1063
    • (2005) Neurosurgery , vol.57
    • Henderson, J.M.1    Tkach, J.2    Phillips, M.3    Baker, K.4    Shellock, F.G.5    Rezai, A.R.6
  • 6
    • 0035515589 scopus 로고    scopus 로고
    • Functional magnetic resonance imaging during deep brain stimulation: a pilot study in four patients with Parkinson's disease
    • Jech R., Urgošík D., Tintěra J., et al. Functional magnetic resonance imaging during deep brain stimulation: a pilot study in four patients with Parkinson's disease. Mov. Disord. 16 (2001) 1126-1132
    • (2001) Mov. Disord. , vol.16 , pp. 1126-1132
    • Jech, R.1    Urgošík, D.2    Tintěra, J.3
  • 7
    • 40349084189 scopus 로고    scopus 로고
    • Magnetic resonance imaging of implanted deep brain stimulators: experience in a large series
    • Larson P.S., Richardson R.M., Starr P.A., and Martin A.J. Magnetic resonance imaging of implanted deep brain stimulators: experience in a large series. Stereotact. Funct. Neurosurg. 86 2 (2008) 92-100
    • (2008) Stereotact. Funct. Neurosurg. , vol.86 , Issue.2 , pp. 92-100
    • Larson, P.S.1    Richardson, R.M.2    Starr, P.A.3    Martin, A.J.4
  • 8
    • 41249092714 scopus 로고    scopus 로고
    • Deep brain stimulation for Parkinson's disease
    • Limousin P., and Martinez-Torres I. Deep brain stimulation for Parkinson's disease. Neurotherapeutics 5 (2008) 309-319
    • (2008) Neurotherapeutics , vol.5 , pp. 309-319
    • Limousin, P.1    Martinez-Torres, I.2
  • 9
    • 0035933158 scopus 로고    scopus 로고
    • DBS and diathermy interaction induces severe CNS damage
    • Nutt J.G., Anderson V.C., Peacock J.H., et al. DBS and diathermy interaction induces severe CNS damage. Neurology (2001) 1384-1386
    • (2001) Neurology , pp. 1384-1386
    • Nutt, J.G.1    Anderson, V.C.2    Peacock, J.H.3
  • 11
    • 7244248606 scopus 로고    scopus 로고
    • Safety of cardiovascular magnetic resonance in patients with cardiovascular implants and devices
    • Prasad S.K., and Pennell D.J. Safety of cardiovascular magnetic resonance in patients with cardiovascular implants and devices. Heart 90 (2004) 1241-1244
    • (2004) Heart , vol.90 , pp. 1241-1244
    • Prasad, S.K.1    Pennell, D.J.2
  • 12
    • 1942533027 scopus 로고    scopus 로고
    • Neurostimulation systems used for deep brain stimulation (DBS): MR safety issues and implications of failing to follow safety recommendations.
    • Rezai A.R., Phillips M., et al. Neurostimulation systems used for deep brain stimulation (DBS): MR safety issues and implications of failing to follow safety recommendations. Invest. Radiol. 39 (2004) 300-303
    • (2004) Invest. Radiol. , vol.39 , pp. 300-303
    • Rezai, A.R.1    Phillips, M.2
  • 14
    • 0141455180 scopus 로고    scopus 로고
    • Transient dystonia following magnetic resonance imaging in a patient with deep brain stimulation electrodes for the treatment of Parkinson disease. Case report
    • Spiegel J., Fuss G., Backens M., Reith W., Magnus T., Becker G., Moringlane J.R., and Dillmann U. Transient dystonia following magnetic resonance imaging in a patient with deep brain stimulation electrodes for the treatment of Parkinson disease. Case report. J. Neurosurg. 99 (2003) 772-774
    • (2003) J. Neurosurg. , vol.99 , pp. 772-774
    • Spiegel, J.1    Fuss, G.2    Backens, M.3    Reith, W.4    Magnus, T.5    Becker, G.6    Moringlane, J.R.7    Dillmann, U.8
  • 15
    • 0032956495 scopus 로고    scopus 로고
    • Magnetic resonance imaging with implanted neurostimulators: an in vitro and in vivo study
    • Tronnier V.M., Staubert A., Hähnel S., et al. Magnetic resonance imaging with implanted neurostimulators: an in vitro and in vivo study. Neurosurgery 44 (1999) 118-126
    • (1999) Neurosurgery , vol.44 , pp. 118-126
    • Tronnier, V.M.1    Staubert, A.2    Hähnel, S.3
  • 16
    • 37349099064 scopus 로고    scopus 로고
    • The treatment of movement disorders by deep brain stimulation
    • Yu H., and Neimat J.S. The treatment of movement disorders by deep brain stimulation. eurotherapeutics 5 (2008) 26-36
    • (2008) eurotherapeutics , vol.5 , pp. 26-36
    • Yu, H.1    Neimat, J.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.