메뉴 건너뛰기




Volumn 55, Issue 4, 2011, Pages 357-368

Validation of the analysis of respirable crystalline silica (Quartz) in foams used with CIP 10-R samplers

Author keywords

CIP 10 R; foam; quartz; X ray diffraction

Indexed keywords

ACID ATTACK; ANALYTICAL UNCERTAINTY; BRUSSELS , BELGIUM; CALIBRATION CURVES; CHEMICAL AGENT; CIP 10-R; CRYSTALLINE SILICA; EXPOSURE LIMIT VALUE; MATRIX; REFLECTION LINES; RESPIRABLE FRACTIONS;

EID: 79955045349     PISSN: 00034878     EISSN: 14753162     Source Type: Journal    
DOI: 10.1093/annhyg/meq093     Document Type: Article
Times cited : (4)

References (22)
  • 2
    • 84864172810 scopus 로고
    • NF X 43-295 Détermination par rayons X de la concentration de dépôt alvéolaire de silice cristalline- Echantillonnage par dispositif àcoupelle rotative la plaine saint denis
    • AFNOR
    • AFNOR. (1995a) NF X 43-295 Détermination par rayons X de la concentration de dépôt alvéolaire de silice cristalline- Echantillonnage par dispositif àcoupelle rotative. La Plaine Saint Denis, France: Association Francxaise de Normalisation.
    • (1995) France: Association Francxaise de Normalisation
  • 3
    • 84864163302 scopus 로고
    • NF X 43-296 Détermination par rayons X de la fraction conventionnelle alvéolaire de la silice cristalline- Echantillonnage sur membrane filtrante la plaine saint denis
    • AFNOR
    • AFNOR. (1995b) NF X 43-296 Détermination par rayons X de la fraction conventionnelle alvéolaire de la silice cristalline- Echantillonnage sur membrane filtrante. La Plaine Saint Denis, France: Association Francxaise de Normalisation.
    • (1995) France: Association Francxaise de Normalisation
  • 4
    • 84864169398 scopus 로고    scopus 로고
    • XP X43-243 Dosage par spectrométrie infrarouge àtranformée de fourier de la silice crystalline echantillonnage par dispositif àcoupelle tournante ou sur membrane filtrante la plaine saint denis
    • AFNOR
    • AFNOR. (2005) XP X43-243 Dosage par spectrométrie infrarouge àtranformée de Fourier de la silice cristalline. Echantillonnage par dispositif àcoupelle tournante ou sur membrane filtrante. La Plaine Saint Denis, France: Association Francxaise de Normalisation.
    • (2005) France: Association Francxaise de Normalisation
  • 5
    • 0010734118 scopus 로고
    • Quantitative X-ray diffractometry on milligram samples prepared on silver filters
    • Altree-Williams S. (1977) Quantitative X-ray diffractometry on milligram samples prepared on silver filters. Anal Chem; 49: 429-32.
    • (1977) Anal. Chem. , vol.49 , pp. 429-432
    • Altree-Williams, S.1
  • 6
    • 0017593516 scopus 로고
    • Quantitative X-ray diffractometry on respirable dust collected on nuclepore filters
    • Altree-Williams S, Lee J, Mezin NV. (1977) Quantitative X-ray diffractometry on respirable dust collected on nuclepore filters. Ann Occup Hyg; 20: 109-26. (Pubitemid 8393085)
    • (1977) Annals of Occupational Hygiene , vol.20 , Issue.2 , pp. 109-126
    • Altree Williams, S.1    Lee, J.2    Mezin, N.V.3
  • 7
    • 84864168408 scopus 로고    scopus 로고
    • Workplace atmospheres-general requirements for the performance of procedures for the measurements of chemical agents
    • CEN Belgium: EN 482 Comité Européen de normalisation CEN
    • CEN. (2006) Workplace atmospheres-general requirements for the performance of procedures for the measurements of chemical agents. Brussels, Belgium: EN 482 Comité Européen de normalisation (CEN).
    • (2006) Brussels
  • 8
    • 84864165055 scopus 로고    scopus 로고
    • Pr EN13890:2009 workplace exposure-procedures for measuring metals and metalloids airborne particules-requirements and test methods
    • CEN Belgium: Comité Européen de normalisation CEN
    • CEN. (2009) Pr EN13890:2009Workplace exposure-procedures for measuring metals and metalloids airborne particules- requirements and test methods. Brussels, Belgium: Comité Européen de normalisation (CEN).
    • (2009) Brussels
  • 10
    • 0019998954 scopus 로고
    • On the use of various filter substrates for quantitative particulate analysis by X-ray diffraction
    • Davis L, Johnson LR. (1982) On the use of various filter substrates for quantitative particulate analysis by X-ray diffraction. Atmos Environ; 16: 273-82.
    • (1982) Atmos. Environ. , vol.16 , pp. 273-282
    • Davis, L.1    Johnson, L.R.2
  • 11
    • 4243774595 scopus 로고
    • Particle size effects in the determination of respirable a-quartz by X-ray diffraction
    • Edmonds JW, Henslee NW, Guerra RE. (1977) Particle size effects in the determination of respirable a-Quartz by X-ray diffraction. Anal chem; 49: 2196-203.
    • (1977) Anal. Chem. , vol.49 , pp. 2196-2203
    • Edmonds, J.W.1    Henslee, N.W.2    Guerra, R.E.3
  • 12
    • 79954985857 scopus 로고    scopus 로고
    • MDHS 101 Crystalline silica in respirable airborne dusts
    • HSE London UK: Health and Safety Executive
    • HSE. (2005) MDHS 101 Crystalline silica in respirable airborne dusts. Direct-on-filter analyses by infrared spectroscopy and X-ray diffraction. London, UK: Health and Safety Executive.
    • (2005) Direct-on-Filter Analyses by Infrared Spectroscopy and X-ray Diffraction
  • 14
    • 27944498280 scopus 로고    scopus 로고
    • Comparison of direct (X-Ray diffraction and infrared spectrophotometry) and indirect (infrared spectrophotometry) methods for the analysis of α-quartz in airborne dusts
    • DOI 10.1093/annhyg/mei024
    • Kauffer E, Masson A, Moulut JC et al. (2005) Comparison of direct (X-ray diffraction and infrared spectrometry) and indirect (infrared spectrometry) methods for the analysis of a-Quartz in airborne dust. Ann Occup Hyg; 49: 661-71. (Pubitemid 41668763)
    • (2005) Annals of Occupational Hygiene , vol.49 , Issue.8 , pp. 661-671
    • Kauffer, E.1    Masson, A.2    Moulut, J.C.3    Lecaque, T.4    Protois, J.C.5
  • 17
    • 79954990313 scopus 로고    scopus 로고
    • Silica crystalline by IR KBr pellet
    • NIOSH March 2003. Cincinnati OH: National Institute for Occupational Safety and Health.
    • NIOSH. (2003a) Silica, crystalline, by IR (KBr pellet). Method 7602, Issue 3, 15 March 2003. Cincinnati, OH: National Institute for Occupational Safety and Health.
    • (2003) Method , vol.7602 , Issue.3
  • 18
    • 79954987189 scopus 로고    scopus 로고
    • Silica crystalline by XRD filter redeposition
    • NIOSH15 March 2003. Cincinnati OH: National Institute for Occupational Safety and Health.
    • NIOSH. (2003b) Silica, crystalline, by XRD (filter redeposition). Method 7500, Issue 4, 15 March 2003. Cincinnati, OH: National Institute for Occupational Safety and Health.
    • (2003) Method , vol.7500 , Issue.4
  • 19
    • 51849143358 scopus 로고    scopus 로고
    • OSHA Salt Lake City UT: U.S. Department of Labor Occupational Safety and Health Administration.
    • OSHA. (1996) Quartz and cristobalite in workplace atmospheres: methods ID-142. Salt Lake City, UT: U.S. Department of Labor, Occupational Safety and Health Administration.
    • (1996) Quartz and Cristobalite in Workplace Atmospheres: Methods ID-142
  • 20
    • 0031321805 scopus 로고    scopus 로고
    • Evaluation of the detectability and quantification of respirable crystalline silica by X-ray powder diffraction methods
    • Smith DK. (1997) Evaluation of the detectability and quantification of respirable crystalline silica by X-ray powder diffraction methods. Power Diffr; 12: 200-27.
    • (1997) Power Diffr. , vol.12 , pp. 200-227
    • Smith, D.K.1
  • 21
    • 30644473386 scopus 로고    scopus 로고
    • The performance of different analytical approaches measuring respirable quartz in the workplace analysis scheme for proficiency wasp and the precision and limit of detection of the direct on-air-filter analysis methods
    • Stacey P. (2005) The performance of different analytical approaches measuring respirable quartz in the workplace analysis scheme for proficiency (WASP) and the precision and limit of detection of the direct on-air-filter analysis methods. J ASTM Int; 2: 1-13.
    • (2005) J. ASTM Int. , vol.2 , pp. 1-13
    • Stacey, P.1
  • 22
    • 69049084610 scopus 로고    scopus 로고
    • An international comparison of the crystallinity of calibration materials for the analysis of respirable a-Quartz using X-ray diffraction and a comparison with results from the infrared KBr disc method
    • Stacey P, Kauffer E, Moulut JC et al. (2009) An international comparison of the crystallinity of calibration materials for the analysis of respirable a-Quartz using X-ray diffraction and a comparison with results from the infrared KBr disc method. Ann Occup Hyg; 53: 639-49.
    • (2009) Ann. Occup. Hyg. , vol.53 , pp. 639-649
    • Stacey, P.1    Kauffer, E.2    Moulut, J.C.3