메뉴 건너뛰기




Volumn 27, Issue 3, 2011, Pages 199-213

Quality control of superficial hyperthermia by treatment evaluation

Author keywords

control; evaluation; quality assurance; steering; Superficial hyperthermia

Indexed keywords

ARTICLE; AWARENESS; BODY TEMPERATURE; CLINICAL EFFECTIVENESS; CLINICAL EVALUATION; HUMAN; HYPERTHERMIC THERAPY; QUALITY CONTROL; SUPERFICIAL HYPERTHERMIA;

EID: 79955035034     PISSN: 02656736     EISSN: 14645157     Source Type: Journal    
DOI: 10.3109/02656736.2010.525226     Document Type: Article
Times cited : (17)

References (43)
  • 1
    • 0028934336 scopus 로고
    • Randomised trial of hyperthermia as adjuvant to radiotherapy for recurrent or metastatic malignant melanoma
    • Overgaard J, Gonzalez Gonzalez D, Hulshof MCCM, Arcangeli G, Dahl O, Mella O, Bentzen SM. Randomised trial of hyperthermia as adjuvant to radiotherapy for recurrent or metastatic malignant melanoma. Lancet 1995;345: 540-543.
    • (1995) Lancet , vol.345 , pp. 540-543
    • Overgaard, J.1    Gonzalez Gonzalez, D.2    McCm, H.3    Arcangeli, G.4    Dahl, O.5    Mella, O.6    Bentzen, S.M.7
  • 4
    • 0032972960 scopus 로고    scopus 로고
    • Comparison of the clinical effectiveness of the 433 MHz lucite cone applicator with that of a conventional waveguide applicator in applications of superficial hyperthermia
    • DOI 10.1016/S0360-3016(98)00443-X, PII S036030169800443X
    • Rietveld PJM, Van Putten WLJ, Van der Zee J, Van Rhoon GC. Comparison of the clinical effectiveness of the 433 Mhz lucite cone applicator with that of a conventional waveguide applicator in applications of superficial hyperther-mia. Int J Radiat Oncol Biol Phys 1999;43:681-687. (Pubitemid 29107193)
    • (1999) International Journal of Radiation Oncology Biology Physics , vol.43 , Issue.3 , pp. 681-687
    • Rietveld, P.J.M.1    Van Putten, W.L.J.2    Van Der Zee, J.3    Van Rhoon, G.C.4
  • 5
    • 4444309860 scopus 로고    scopus 로고
    • Assessment of the performance characteristics of a prototype 12-element capacitive contact flexible microstrip applicator (CFMA-12) for superficial hyperthermia
    • DOI 10.1080/02656730410001695915
    • Lee WM, Gelvich EA, Van der Baan P, Mazokhin VN, Van Rhoon GC. Assessment of the performance characteristics of a prototype 12-element capacitive contact flexible microstrip applicator (CFMA-12) for superficial hyperthermia. Int J Hyperthermia 2004;20:607-624. (Pubitemid 39162541)
    • (2004) International Journal of Hyperthermia , vol.20 , Issue.6 , pp. 607-624
    • Lee, W.M.1    Gelvich, E.A.2    Van Der Baan, P.3    Mazokhin, V.N.4    Van Rhoon, G.C.5
  • 6
    • 0027535304 scopus 로고
    • Pre-clinical evaluation of a microwave planar array applicator for superficial hyperthermia
    • Diederich CJ, Stauffer PR. Preclinical evaluation of a microwave planar array applicator for superficial hyperther-mia. Int J Hyperthermia 1993;9:227-246. (Pubitemid 23099172)
    • (1993) International Journal of Hyperthermia , vol.9 , Issue.2 , pp. 227-246
    • Diederich, C.J.1    Stauffer, P.R.2
  • 9
    • 0035020640 scopus 로고    scopus 로고
    • Theoretical characterization of dual concentric conductor microwave applicators for hyperthermia at 433 MHz
    • Rossetto F, Stauffer PR. Theoretical characterization ofdual concentric conductor microwave applicators for hyperthermia at 433MHz. Int J Hyperthermia 2001;17:258-270. (Pubitemid 32421607)
    • (2001) International Journal of Hyperthermia , vol.17 , Issue.3 , pp. 258-270
    • Rossetto, F.1    Stauffer, P.R.2
  • 10
    • 0034327892 scopus 로고    scopus 로고
    • Neuman DG Dual-mode antenna design for microwave heating and noninvasive thermometry of superficial tissue disease
    • Jacobsen S, Stauffer PR, Neuman DG Dual-mode antenna design for microwave heating and noninvasive thermometry of superficial tissue disease. IEEE Trans Biomed Eng 2000;47:1500-1509.
    • (2000) IEEE Trans Biomed Eng , vol.47 , pp. 1500-1509
    • Jacobsen, S.1    Stauffer, P.R.2
  • 11
    • 33750557008 scopus 로고    scopus 로고
    • Multilayer conformal applicator for microwave heating and brachytherapy treatment of superficial tissue disease
    • DOI 10.1080/02656730600931815, PII R061665162655216
    • Juang T, Stauffer PR, Neuman DG, Schlorff JL. Multilayer conformal applicator for microwave heating and brachyther-apy treatment of superficial tissue disease. Int J Hyperthermia 2006;22:527-544. (Pubitemid 44669660)
    • (2006) International Journal of Hyperthermia , vol.22 , Issue.7 , pp. 527-544
    • Juang, T.1    Stauffer, P.R.2    Neuman, D.G.3    Schlorff, J.L.4
  • 13
    • 0036085971 scopus 로고    scopus 로고
    • Model-predictive control of hyperthermia treatments
    • DOI 10.1109/TBME.2002.1010846, PII S0018929402057701
    • Arora D, Skliar M, Roemer RB. Model-predictive control of hyperthermia treatments. IEEE Trans Biomed Eng 2002;49:629-639. (Pubitemid 34651456)
    • (2002) IEEE Transactions on Biomedical Engineering , vol.49 , Issue.7 , pp. 629-639
    • Arora, D.1    Skliar, M.2    Roemer, R.B.3
  • 14
    • 0027302360 scopus 로고
    • Automation of temperature control for large-array microwave surface applicators
    • Zhou L, Fessenden P. Automation of temperature control for large-array microwave surface applicators. Int J Hyperthermia 1993;9:479-490. (Pubitemid 23182258)
    • (1993) International Journal of Hyperthermia , vol.9 , Issue.3 , pp. 479-490
    • Zhou, L.1    Fessenden, P.2
  • 15
    • 0029347495 scopus 로고
    • Multipoint temperature control during hyperthermia treatments: Theory and simulation
    • VanBaren P, Ebbini ES. Multipoint temperature control during hyperthermia treatments: Theory and simulation. IEEE Trans Biomed Eng 1995;42:818-827.
    • (1995) IEEE Trans Biomed Eng , vol.42 , pp. 818-827
    • Vanbaren, P.1    Ebbini, E.S.2
  • 16
    • 0026998375 scopus 로고
    • Reduced-order modeling for hyper-thermia control
    • Potocki JK, Tharp HS. Reduced-order modeling for hyper-thermia control. IEEE Trans Biomed Eng 1992;39: 1265-1273.
    • (1992) IEEE Trans Biomed Eng , vol.39 , pp. 1265-1273
    • Potocki, J.K.1    Tharp, H.S.2
  • 17
    • 63649088106 scopus 로고    scopus 로고
    • The performance of a reduced-order adaptive controller when used in multi-antenna hyperthermia treatments with nonlinear temperature-depen-dent perfusion
    • Cheng KS, Yuan Y, Li Z, Stauffer PR, Maccarini P, Joines WT, Dewhirst MW, Das SK. The performance of a reduced-order adaptive controller when used in multi-antenna hyperthermia treatments with nonlinear temperature-depen-dent perfusion. Phys Med Biol 2009;54:1979-1995.
    • (2009) Phys Med Biol , vol.54 , pp. 1979-1995
    • Cheng, K.S.1    Yuan, Y.2    Li, Z.3    Stauffer, P.R.4    MacCarini, P.5    Joines, W.T.6    Dewhirst, M.W.7    Das, S.K.8
  • 18
    • 0037423950 scopus 로고    scopus 로고
    • A temperature-based feedback control system for electromagnetic phased-array hyperthermia: Theory and simulation
    • DOI 10.1088/0031-9155/48/5/306, PII S0031915503521807
    • Kowalski ME, Jin J-M. A temperature-based feedback control system for electromagnetic phased-array hyperthermia: Theory and simulation. Phys Med Biol 2003;48:633-651. (Pubitemid 36335897)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.5 , pp. 633-651
    • Kowalski, M.E.1    Jin, J.-M.2
  • 21
    • 0023376609 scopus 로고
    • The use of implanted closed-tip catheters for the introduction of thermometry probes during local hyper-thermia treatment series
    • Van der Zee J, Van Rhoon GC, Broekmeyer-Reurink MP, Reinhold HS. The use of implanted closed-tip catheters for the introduction of thermometry probes during local hyper-thermia treatment series. Int J Hyperthermia 1987;3:337-345.
    • (1987) Int J Hyperthermia , vol.3 , pp. 337-345
    • Van Der Zee, J.1    Van Rhoon, G.C.2    Broekmeyer-Reurink, M.P.3    Reinhold, H.S.4
  • 23
    • 34249012828 scopus 로고    scopus 로고
    • Quantitative validation of the 3D SAR profile of hyperthermia applicators using the gamma method
    • DOI 10.1088/0031-9155/52/11/010, PII S0031915507428974, 010
    • De Bruijne M, Samaras T, Chavannes N, Van Rhoon GC. Quantitative validation of the 3D SARprofile of hyperthermia applicators using the gamma method. Phys Med Biol 2007;52:3075-3088. (Pubitemid 46795248)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.11 , pp. 3075-3088
    • De Bruijne, M.1    Samaras, T.2    Chavannes, N.3    Van Rhoon, G.C.4
  • 24
    • 0031858460 scopus 로고    scopus 로고
    • Quantitative evaluation of 2 x 2 arrays of Lucite cone applicators in flat layered phantoms using Gaussian-beam-predicted and thermographically measured SAR distributions
    • DOI 10.1088/0031-9155/43/8/015, PII S0031915598855747
    • Rietveld PJM, Lumori MLD, Van der Zee J, Van Rhoon GC. Quantitative evaluation of 2 × 2 arrays of Lucite cone appli-cators in flat layered phantoms using Gaussian beam predicted and thermographically measured SAR distributions. Phys Med Biol 1998;43:2207-2220. (Pubitemid 28372618)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.8 , pp. 2207-2220
    • Rietveld, P.J.M.1    Lumori, M.L.D.2    Van Der Zee, J.3    Van Rhoon, G.C.4
  • 25
    • 77149158488 scopus 로고    scopus 로고
    • Design and test of a 434MHz multi-channel amplifier system for targeted hyperthermia applicators
    • Bakker JF, Paulides MM, Westra AH, Schippers H, Van Rhoon GC. Design and test of a 434MHz multi-channel amplifier system for targeted hyperthermia applicators. Int J Hyperthermia 2010;26:158-170.
    • (2010) Int J Hyperthermia , vol.26 , pp. 158-170
    • Bakker, J.F.1    Paulides, M.M.2    Westra, A.H.3    Schippers, H.4    Van Rhoon, G.C.5
  • 26
    • 31544474900 scopus 로고    scopus 로고
    • Effects of waterbolus size, shape and configuration on the SAR distribution pattern of the Lucite cone applicator
    • DOI 10.1080/02656730500384297, PII L332187103321
    • De Bruijne M, Samaras T, Bakker JF, van Rhoon GC. Effects of waterbolus size, shape and configuration on the SAR distribution pattern of the Lucite cone applicator. Int J Hyperthermia 2006;22:15-28. (Pubitemid 43158214)
    • (2006) International Journal of Hyperthermia , vol.22 , Issue.1 , pp. 15-28
    • De Bruijne, M.1    Samaras, T.2    Bakker, J.F.3    Van Rhoon, G.C.4
  • 28
    • 79955003988 scopus 로고    scopus 로고
    • Erasmus MC-Daniel den Hoed Cancer Center Dutch. (EMC-DDHCC internal report)
    • [Erasmus MC guideline for superficial hyperthermia]. Erasmus MC-Daniel den Hoed Cancer Center 2004. Dutch. (EMC-DDHCC internal report).
    • (2004) [Erasmus MC Guideline for Superficial Hyperthermia]
  • 31
    • 33745111183 scopus 로고    scopus 로고
    • Noninvasive magnetic resonance thermography of soft tissue sarcomas during regional hyperthermia: Correlation with response and direct thermometry
    • DOI 10.1002/cncr.22114
    • Gellerman J, Hildebrandt B, Issels R, Ganter H, Wlodarczyk W, Budach V, Felix R, Tunn P-U, Reichardt P, Wust P. Noninvasive magnetic resonance thermography of soft tissue sarcomas during regional hyperthermia-correla-tion with response and direct thermometry. Cancer 2006;107:1373-1382. (Pubitemid 44452788)
    • (2006) Cancer , vol.107 , Issue.6 , pp. 1373-1382
    • Gellermann, J.1    Hildebrandt, B.2    Issels, R.3    Ganter, H.4    Wlodarczyk, W.5    Budach, V.6    Felix, R.7    Tunn, P.-U.8    Reichardt, P.9    Wust, P.10
  • 32
    • 28444458878 scopus 로고    scopus 로고
    • Introduction: Non-invasive ther-mometry for thermotherapy
    • Van Rhoon GC, Wust P. Introduction: Non-invasive ther-mometry for thermotherapy. Int J Hyperthermia 2005;21:489-495.
    • (2005) Int J Hyperthermia , vol.21 , pp. 489-495
    • Van Rhoon, G.C.1    Wust, P.2
  • 33
    • 0027225443 scopus 로고
    • Non-invasive microwave multifrequency radiometry used in microwave hyperthermia for bidimensional reconstruction of temperature patterns
    • Dubois L, Pribetich J, Fabre JJ, Chive M, Moschetto Y. Non-invasive microwave multifrequency radiometry used in micro-wave hyperthermia for bidimensional reconstruction of tem-perature patterns. Int J Hyperthermia 1993;9:415-431. (Pubitemid 23182253)
    • (1993) International Journal of Hyperthermia , vol.9 , Issue.3 , pp. 415-431
    • Dubois, L.1    Pribetich, J.2    Fabre, J.-J.3    Chive, M.4    Moschetto, Y.5
  • 34
    • 0031965608 scopus 로고    scopus 로고
    • The feasibility of MRI feedback control for intracavitary phased array hyperthermia treatments
    • Hutchinson E, Dahleh M, Hynynen K. The feasibility of MRI feedback control for intracavitary phased array hyperthermia treatments. IntJHyperthermia 1998;14:39-56. (Pubitemid 28040813)
    • (1998) International Journal of Hyperthermia , vol.14 , Issue.1 , pp. 39-56
    • Hutchinson, E.1    Dahleh, M.2    Hynynen, K.3
  • 36
    • 36649022409 scopus 로고    scopus 로고
    • Adaptation of antenna profiles for control of MR guided hyperthermia (HT) in a hybrid MR-HT system
    • DOI 10.1118/1.2804617
    • Weihrauch M, Wust P, Weiser M, Nadobny J, Eisenhardt S, Budach V, Gellermann J. Adaptation of antenna profiles for control of MR guided hyperthermia (HT) in a hybrid MR-HT system. Med Phys 2007;34:4717-4725. (Pubitemid 350197710)
    • (2007) Medical Physics , vol.34 , Issue.12 , pp. 4717-4725
    • Weihrauch, M.1    Wust, P.2    Weiser, M.3    Nadobny, J.4    Eisenhardt, S.5    Budach, V.6    Gellermann, J.7
  • 37
    • 77749246595 scopus 로고    scopus 로고
    • Effective learning strategies for real-time image-guided adaptive control of multiple-source hyperthermia applicators
    • Cheng KS, Dewhirst MW, Stauffer PR, Das S. Effective learning strategies for real-time image-guided adaptive control of multiple-source hyperthermia applicators. Med Phys 2010;37:1285-1297.
    • (2010) Med Phys , vol.37 , pp. 1285-1297
    • Cheng, K.S.1    Dewhirst, M.W.2    Stauffer, P.R.3    Das, S.4
  • 38
    • 58149260335 scopus 로고    scopus 로고
    • Complaint-adaptive power density optimization as a tool for HTP-guided steering in deep hyperthermia treatment of pelvic tumors
    • Complaint-adaptive power density optimization as a tool for HTP-guided steering in deep hyperthermia treatment of pelvic tumors. Canters RAM, Franckena M, Van der Zee J, Van Rhoon GC. Phys Med Biol 2008;53:6799-6820.
    • (2008) Phys Med Biol , vol.53 , pp. 6799-6820
    • Ram, C.1    Franckena, M.2    Van Der Zee, J.3    Van Rhoon, G.C.4
  • 40
    • 77149138667 scopus 로고    scopus 로고
    • Clinical implementation of hyperthermia treatment planning guided steering: A cross over trial to assess its current contribution to treatment quality
    • Franckena M, Canters R, Termorshuizen F, Van der Zee J, Van Rhoon G Clinical implementation of hyperthermia treatment planning guided steering: A cross over trial to assess its current contribution to treatment quality. Int J Hyperthermia 2010;26:145-157.
    • (2010) Int J Hyperthermia , vol.26 , pp. 145-157
    • Franckena, M.1    Canters, R.2    Termorshuizen, F.3    Van Der Zee, J.4    Van Rhoon, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.