메뉴 건너뛰기




Volumn 23, Issue 5, 2007, Pages 417-429

Benefits of superficial hyperthermia treatment planning: Five case studies

Author keywords

FDTD; SAR; Superficial hyperthermia; Treatment planning

Indexed keywords

AGED; ARTICLE; BREAST CANCER; BREAST CARCINOMA; CANCER RADIOTHERAPY; CASE STUDY; CERCLAGE; CLINICAL ARTICLE; FEASIBILITY STUDY; FEMALE; HUMAN; HYPERTHERMIC THERAPY; MALIGNANT NEOPLASTIC DISEASE; MALIGNANT NEURILEMOMA; MASTECTOMY; MEDICAL EDUCATION; MELANOMA; MERKEL CELL TUMOR; METAL IMPLANTATION; NERVE SURGERY; PREDICTION; RISK ASSESSMENT; SIMULATION; TREATMENT CONTRAINDICATION; TREATMENT PLANNING;

EID: 34547992409     PISSN: 02656736     EISSN: 14645157     Source Type: Journal    
DOI: 10.1080/02656730701502077     Document Type: Article
Times cited : (51)

References (32)
  • 3
    • 0032902780 scopus 로고    scopus 로고
    • Optimization of pelvic heating rate distributions with electromagnetic phased arrays
    • Paulsen, KD, Geimer, S., Tang, J. and Boyse, WE (1999) Optimization of pelvic heating rate distributions with electromagnetic phased arrays. Int J Hyperthermia, 15, pp. 157-186.
    • (1999) Int J Hyperthermia , vol.15 , pp. 157-186
    • Paulsen, K.D.1    Geimer, S.2    Tang, J.3    Boyse, W.E.4
  • 5
    • 0034083356 scopus 로고    scopus 로고
    • Hyperthermia treatment planning
    • Lagendijk, JJW (2000) Hyperthermia treatment planning. Phys Med Biol, 45, pp. R61-R76.
    • (2000) Phys Med Biol , vol.45
    • Lagendijk, J.J.W.1
  • 6
    • 0029744989 scopus 로고    scopus 로고
    • Simulation studies promote technological development of radiofrequency phased array hyperthermia
    • Wust, P., Seebass, M., Nadobny, J., Deuflhard, P., Monich, G. and Felix, R. (1996) Simulation studies promote technological development of radiofrequency phased array hyperthermia. Int J Hyperthermia, 12, pp. 477-494.
    • (1996) Int J Hyperthermia , vol.12 , pp. 477-494
    • Wust, P.1    Seebass, M.2    Nadobny, J.3    Deuflhard, P.4    Monich, G.5    Felix, R.6
  • 8
    • 0034932745 scopus 로고    scopus 로고
    • Electromagnetic phased arrays for regional hyperthermia: Optimal frequency and antenna arrangement
    • Seebass, M., Beck, R., Gellermann, J., Nadobny, J. and Wust, P. (2001) Electromagnetic phased arrays for regional hyperthermia: Optimal frequency and antenna arrangement. Int J Hyperthermia, 17, pp. 321-336.
    • (2001) Int J Hyperthermia , vol.17 , pp. 321-336
    • Seebass, M.1    Beck, R.2    Gellermann, J.3    Nadobny, J.4    Wust, P.5
  • 10
    • 0027245006 scopus 로고
    • The Stanford 3-D hyperthermia treatment planning - Technical review and clinical summary
    • Sullivan, DM, Ben-Yosef, R. and Kapp, DS (1993) The Stanford 3-D hyperthermia treatment planning - Technical review and clinical summary. Int J Hyperthermia, 9, pp. 627-643.
    • (1993) Int J Hyperthermia , vol.9 , pp. 627-643
    • Sullivan, D.M.1    Ben-Yosef, R.2    Kapp, D.S.3
  • 11
    • 0028879788 scopus 로고
    • Simulation of electromagnetically induced hyperthermia: A finite element gridding method
    • Das, SK, Clegg, ST, Anscher, MS and Samulski, TV (1995) Simulation of electromagnetically induced hyperthermia: A finite element gridding method. Int J Hyperthermia, 11, pp. 797-808.
    • (1995) Int J Hyperthermia , vol.11 , pp. 797-808
    • Das, S.K.1    Clegg, S.T.2    Anscher, M.S.3    Samulski, T.V.4
  • 12
    • 0343484449 scopus 로고    scopus 로고
    • Patient specific treatment planning in regional hyperthermia: Practical experience in Bergen
    • (dissertation), Aalborg University, Denmark
    • Hornsleth, SN, Seebass, M., Mella, O. and Dahl, O. (1996) Patient specific treatment planning in regional hyperthermia: Practical experience in Bergen. Radiofrequency Regional Hyperthermia (dissertation), Aalborg University, Denmark
    • (1996) Radiofrequency Regional Hyperthermia
    • Hornsleth, S.N.1    Seebass, M.2    Mella, O.3    Dahl, O.4
  • 16
    • 0038759020 scopus 로고    scopus 로고
    • Edge-element based finite element analysis of microwave hyperthermia treatments for superficial tumours on the chest wall
    • Kumaradas, JC and Sherar, MD (2003) Edge-element based finite element analysis of microwave hyperthermia treatments for superficial tumours on the chest wall. Int J Hyperthermia, 19, pp. 414-430.
    • (2003) Int J Hyperthermia , vol.19 , pp. 414-430
    • Kumaradas, J.C.1    Sherar, M.D.2
  • 17
    • 0031985968 scopus 로고    scopus 로고
    • A 433 MHz Lucite cone waveguide applicator for superficial hyperthermia
    • Van Rhoon, GC, Rietveld, PJ and Van der Zee, J. (1998) A 433 MHz Lucite cone waveguide applicator for superficial hyperthermia. Int J Hyperthermia, 14, pp. 13-27.
    • (1998) Int J Hyperthermia , vol.14 , pp. 13-27
    • Van Rhoon, G.C.1    Rietveld, P.J.2    Van der Zee, J.3
  • 18
    • 31544474900 scopus 로고    scopus 로고
    • Effects of waterbolus size, shape and configuration on the SAR distribution pattern of the Lucite cone applicator
    • De Bruijne, M., Samaras, T., Bakker, JF and Van Rhoon, GC (2006) Effects of waterbolus size, shape and configuration on the SAR distribution pattern of the Lucite cone applicator. Int J Hyperthermia, 22, pp. 15-28.
    • (2006) Int J Hyperthermia , vol.22 , pp. 15-28
    • De Bruijne, M.1    Samaras, T.2    Bakker, J.F.3    Van Rhoon, G.C.4
  • 21
    • 0029957193 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues
    • Gabriel, S., Lau, RW and Gabriel, C. (1996) The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. Phys Med Biol, 41, pp. 2271-2293.
    • (1996) Phys Med Biol , vol.41 , pp. 2271-2293
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 22
    • 0028359255 scopus 로고
    • The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz
    • Joines, WT, Zhang, Y. and Jirtle, RL (1994) The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz. Med Phys, 21, pp. 547-550.
    • (1994) Med Phys , vol.21 , pp. 547-550
    • Joines, W.T.1    Zhang, Y.2    Jirtle, R.L.3
  • 23
    • 34547974973 scopus 로고
    • Treatment planning and modeling in hyperthermia
    • COMAC BME Task Group (4th Medical and Health Research Programme of the European Commission) Tor Vergata Medical Physics Monograph Series, Rome
    • COMAC BME Task Group (1992) Treatment planning and modeling in hyperthermia. A Task Group Report of the European Society for Hyperthermic Oncology in cooperation with a COMAC-BME Concerted Action (4th Medical and Health Research Programme of the European Commission), 12, pp. 0-136. Tor Vergata Medical Physics Monograph Series, Rome
    • (1992) A Task Group Report of the European Society for Hyperthermic Oncology in Cooperation With a COMAC-BME Concerted Action , vol.12 , pp. 0-136
  • 24
    • 0034318001 scopus 로고    scopus 로고
    • Effectiveness of FDTD in predicting SAR distributions from the Lucite cone applicator
    • Samaras, T., Rietveld, PJM and Van Rhoon, GC (2000) Effectiveness of FDTD in predicting SAR distributions from the Lucite cone applicator. IEEE Trans MTT, 48, pp. 2059-2063.
    • (2000) IEEE Trans MTT , vol.48 , pp. 2059-2063
    • Samaras, T.1    Rietveld, P.J.M.2    Van Rhoon, G.C.3
  • 25
    • 34249012828 scopus 로고    scopus 로고
    • Quantitative validation of the 3D SAR profile of hyperthermia applicators using the gamma method
    • De Bruijne, M., Samaras, T., Chavannes, N. and Van Rhoon, GC (2007) Quantitative validation of the 3D SAR profile of hyperthermia applicators using the gamma method. Phys Med Biol, 52, pp. 3075-3088.
    • (2007) Phys Med Biol , vol.52 , pp. 3075-3088
    • De Bruijne, M.1    Samaras, T.2    Chavannes, N.3    Van Rhoon, G.C.4
  • 26
    • 0027054052 scopus 로고
    • Potential hazards of radiative electromagnetic hyperthermia in the presence of multiple metallic surgical clips
    • Lee, ER, Sullivan, DM and Kapp, DS (1992) Potential hazards of radiative electromagnetic hyperthermia in the presence of multiple metallic surgical clips. Int J Hyperthermia, 8, pp. 809-817.
    • (1992) Int J Hyperthermia , vol.8 , pp. 809-817
    • Lee, E.R.1    Sullivan, D.M.2    Kapp, D.S.3
  • 27
    • 0037498193 scopus 로고    scopus 로고
    • Do surgical clips interfere with radiofrequency thermal ablation?
    • Boll, DT, Lewin, JS, Durek, JL and Merkle, EM (2003) Do surgical clips interfere with radiofrequency thermal ablation?. AJR Am J Roentgenol, 180, pp. 1557-1560.
    • (2003) AJR Am J Roentgenol , vol.180 , pp. 1557-1560
    • Boll, D.T.1    Lewin, J.S.2    Durek, J.L.3    Merkle, E.M.4
  • 31
    • 0035020640 scopus 로고    scopus 로고
    • Theoretical characterization of dual concentric conductor microwave applicators for hyperthermia at 433 MHz
    • Rosetto, F. and Stauffer, PR (2001) Theoretical characterization of dual concentric conductor microwave applicators for hyperthermia at 433 MHz. Int J Hyperthermia, 17, pp. 258-270.
    • (2001) Int J Hyperthermia , vol.17 , pp. 258-270
    • Rosetto, F.1    Stauffer, P.R.2
  • 32
    • 13244256869 scopus 로고    scopus 로고
    • Characteristics of microstrip muscle-loaded single-arm archimedean spiral antennas as investigated by FDTD numerical computations
    • Jacobsen, S., Rolfsnes, HO and Stauffer, PR (2005) Characteristics of microstrip muscle-loaded single-arm archimedean spiral antennas as investigated by FDTD numerical computations. IEEE Trans Biomed Eng, 52, pp. 321-330.
    • (2005) IEEE Trans Biomed Eng , vol.52 , pp. 321-330
    • Jacobsen, S.1    Rolfsnes, H.O.2    Stauffer, P.R.3