메뉴 건너뛰기




Volumn 36, Issue 5, 2011, Pages 422-428

Evaluation of rebound tonometer for measuring intraocular pressure at deviated angle and position

Author keywords

Intraocular pressure; Perkins applanation tonometer; Rabbit; Rebound tonometer; Tonopen XL tonometer; Transducer

Indexed keywords

ANIMAL EXPERIMENT; ANTERIOR EYE CHAMBER; ANTERIOR EYE CHAMBER ANGLE; ARTICLE; CORNEA; DIAGNOSTIC ACCURACY; EYE POSITION; INTRAOCULAR PRESSURE; MALE; MEASUREMENT; NONHUMAN; PERKINS HANDHELD APPLANATION TONOMETER; PRESSURE TRANSDUCER; PRIORITY JOURNAL; RABBIT; REBOUND TONOMETER; RELIABILITY; TONOMETER; TONOPEN XL;

EID: 79954994724     PISSN: 02713683     EISSN: 14602202     Source Type: Journal    
DOI: 10.3109/02713683.2010.534574     Document Type: Article
Times cited : (13)

References (16)
  • 1
    • 0017671617 scopus 로고
    • Intraocular pressures in children with glaucoma during halothane anesthesia
    • Ausinsch B, Munson ES, Levy NS. Intraocular pressures in children with glaucoma during halothane anesthesia. Ann Ophthalmol. 1977;9:1391-1394. (Pubitemid 8247134)
    • (1977) Annals of Ophthalmology , vol.9 , Issue.11 , pp. 1391-1394
    • Ausinsch, B.1    Munson, E.S.2    Levy, N.S.3
  • 3
    • 0026004277 scopus 로고
    • The effect of Perkins, Tono-Pen, and Schiötz tonometry on intraocular pressure
    • Whitacre MM, Emig M, Hassanein K. The effect of Perkins, Tono-Pen, and Schiötz tonometry on intraocular pressure. Am J Ophthalmol. 1991;111:59-64.
    • (1991) Am J Ophthalmol. , vol.111 , pp. 59-64
    • Whitacre, M.M.1    Emig, M.2    Hassanein, K.3
  • 7
    • 0024617591 scopus 로고
    • Portable tonometers: A clinical comparison of applanation and indentation devices
    • Chiara GF, Semes LP, Potter JW, et al. Portable tonometers: A clinical comparison of applanation and indentation devices. J Am Optom Assoc 1989;60:105-110.
    • (1989) J Am Optom Assoc , vol.60 , pp. 105-110
    • Chiara, G.F.1    Semes, L.P.2    Potter, J.W.3
  • 8
    • 0030318702 scopus 로고    scopus 로고
    • A new electromechanical method for mea-suring intraocular pressure
    • Kontiola A. A new electromechanical method for mea-suring intraocular pressure. Doc Ophthalmol. 1997;93: 265-276.
    • (1997) Doc Ophthalmol. , vol.93 , pp. 265-276
    • Kontiola, A.1
  • 10
    • 37349001245 scopus 로고    scopus 로고
    • The Influence of Corneal Properties on Rebound Tonometry
    • DOI 10.1016/j.ophtha.2007.03.061, PII S0161642007003442
    • Chui WS, Lam A, Chen D, et al. The infuence of cor-neal properties on rebound tonometry. Ophthalmology. 2008;115:80-84. (Pubitemid 350309417)
    • (2008) Ophthalmology , vol.115 , Issue.1 , pp. 80-84
    • Chui, W.-s.1    Lam, A.2    Chen, D.3    Chiu, R.4
  • 11
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • DOI 10.1191/096228099673819272
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8:135-160. (Pubitemid 29425900)
    • (1999) Statistical Methods in Medical Research , vol.8 , Issue.2 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 34948836324 scopus 로고    scopus 로고
    • Measurement of intraocular pressure (IOP) in chickens using a rebound tonometer: Quantitative evaluation of variance due to position inaccuracies
    • DOI 10.1016/j.exer.2007.07.010, PII S0014483507001996
    • Prashar A, Guggenheim JA, Erichsen JT, et al. Measurement of intraocular pressure (IOP) in chickens using a rebound tonometer: Quantitative evaluation of variance due to posi-tion inaccuracies. Exp Eye Res. 2007;85:563-571. (Pubitemid 47531743)
    • (2007) Experimental Eye Research , vol.85 , Issue.4 , pp. 563-571
    • Prashar, A.1    Guggenheim, J.A.2    Erichsen, J.T.3    Hocking, P.M.4    Morgan, J.E.5
  • 14
    • 0035704347 scopus 로고    scopus 로고
    • The induction/impact tonometer: A new instrument to measure intraocular pressure in the rat
    • DOI 10.1006/exer.2001.1088
    • Kontiola AI, Goldblum D, Mittag T, et al. The induction/impact tonometer: A new instrument to measure intraocular pressure in the rat. Exp Eye Res. 2001;73:781-785. (Pubitemid 34112104)
    • (2001) Experimental Eye Research , vol.73 , Issue.6 , pp. 781-785
    • Kontiola, A.I.1    Goldblum, D.2    Mittag, T.3    Danias, J.4
  • 15
    • 51649121663 scopus 로고    scopus 로고
    • Comparison of intraocular tonometry using three different non-invasive tonometers in children
    • Lasseck J, Jehle T, Feltgen N, et al. Comparison of intraocular tonometry using three different non-invasive tonometers in children. Graefes Arch Clin Exp Ophthalmol. 2008;246:1463-1466.
    • (2008) Graefes Arch Clin Exp Ophthalmol. , vol.246 , pp. 1463-1466
    • Lasseck, J.1    Jehle, T.2    Feltgen, N.3
  • 16
    • 33751060567 scopus 로고    scopus 로고
    • Manometric calibration and comparison of TonoLab and TonoPen tonometers in rats with experimental glaucoma and in normal mice
    • DOI 10.1097/01.ijg.0000212276.57853.19, PII 0006119820061200000007
    • Pease ME, Hammond JC, Quigley HA. Manometric calibra-tion and comparison of TonoLab and TonoPen tonometers in rats with experimental glaucoma and in normal mice. J Glaucoma. 2006;15:512-519. (Pubitemid 44760325)
    • (2006) Journal of Glaucoma , vol.15 , Issue.6 , pp. 512-519
    • Pease, M.E.1    Hammond, J.C.2    Quigley, H.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.