메뉴 건너뛰기




Volumn 35, Issue 4, 2011, Pages 404-410

Use of a Genetic Algorithm for Multiobjective Design Optimization of the Femoral Stem of a Cemented Total Hip Arthroplasty

Author keywords

Cement failure; Computer analysis; Femoral stem; Finite element analysis; Optimization; Total hip replacement

Indexed keywords

ARTHROPLASTY; BONE; CEMENTS; FRACTURE; GENETIC ALGORITHMS; GEOMETRY; HIP PROSTHESES; MULTIOBJECTIVE OPTIMIZATION; ORTHOPEDICS; STAIRS;

EID: 79954993386     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2010.01117.x     Document Type: Article
Times cited : (15)

References (22)
  • 3
    • 0031762032 scopus 로고    scopus 로고
    • Effects of design changes on cemented tapered femoral stem fixation
    • Middleton R, Howie D, Costi K, Sharpe P. Effects of design changes on cemented tapered femoral stem fixation. Clin Orthop 1998;355:47-56.
    • (1998) Clin Orthop , vol.355 , pp. 47-56
    • Middleton, R.1    Howie, D.2    Costi, K.3    Sharpe, P.4
  • 4
    • 79954992616 scopus 로고
    • Coulomb frictional interfaces in modeling cemented total hip replacements
    • Mann KA, Bartel DL, Wright TM, Burstein AH. Coulomb frictional interfaces in modeling cemented total hip replacements. J Biomech 1995;28:1267-78.
    • (1995) J Biomech , vol.28 , pp. 1267-1278
    • Mann, K.A.1    Bartel, D.L.2    Wright, T.M.3    Burstein, A.H.4
  • 5
    • 0033635482 scopus 로고    scopus 로고
    • Early failure of modern cemented stems
    • Barrack RL. Early failure of modern cemented stems. J Arthroplasty 2000;15:1036-50.
    • (2000) J Arthroplasty , vol.15 , pp. 1036-1050
    • Barrack, R.L.1
  • 6
    • 0036208443 scopus 로고    scopus 로고
    • Finite element and experimental models of cemented hip joint reconstructions can produce similar bone and cement strains in pre-clinical tests
    • Stolk J, Verdonschot N, Cristofolini L, Toni A, Huiskes R. Finite element and experimental models of cemented hip joint reconstructions can produce similar bone and cement strains in pre-clinical tests. J Biomech 2002;35:499-510.
    • (2002) J Biomech , vol.35 , pp. 499-510
    • Stolk, J.1    Verdonschot, N.2    Cristofolini, L.3    Toni, A.4    Huiskes, R.5
  • 7
    • 0021712224 scopus 로고
    • Design sensitivity analysis: a new method for implant design and adcomparison with parametric finite analysis
    • Yang RJ, Choi KK, Crowninshfield RD, Brand RA. Design sensitivity analysis: a new method for implant design and adcomparison with parametric finite analysis. J Biomech 1984;17:849-54.
    • (1984) J Biomech , vol.17 , pp. 849-854
    • Yang, R.J.1    Choi, K.K.2    Crowninshfield, R.D.3    Brand, R.A.4
  • 8
    • 0024947002 scopus 로고
    • Mathematical shape optimization of hip prosthesis design
    • Huiskes R, Boeklagen R. Mathematical shape optimization of hip prosthesis design. J Biomech 1989;22:793-804.
    • (1989) J Biomech , vol.22 , pp. 793-804
    • Huiskes, R.1    Boeklagen, R.2
  • 9
    • 0024943182 scopus 로고
    • Shape optimal design of the stem of a cemented hip prosthesis to minimize stress concentration in the cement layer
    • Yoon SY, Jang GH, Kim YY. Shape optimal design of the stem of a cemented hip prosthesis to minimize stress concentration in the cement layer. J Biomech 1989;22:1279-84.
    • (1989) J Biomech , vol.22 , pp. 1279-1284
    • Yoon, S.Y.1    Jang, G.H.2    Kim, Y.Y.3
  • 10
    • 0034189972 scopus 로고    scopus 로고
    • Effects of loading conditions and objective function on three-dimensional shape optimization of femoral components of hip endoprostheses
    • Katoozian H, Davy DT. Effects of loading conditions and objective function on three-dimensional shape optimization of femoral components of hip endoprostheses. Med Eng Physics 2000;22:243-51.
    • (2000) Med Eng Physics , vol.22 , pp. 243-251
    • Katoozian, H.1    Davy, D.T.2
  • 11
    • 4544227014 scopus 로고    scopus 로고
    • Shape optimization of a cementless hip stem for a minimum of interface stress and displacement
    • Fernandes PR, Folgardo J, Ruben RB. Shape optimization of a cementless hip stem for a minimum of interface stress and displacement. Comput Methods Biomech Biomed Engin 2004;7:51-61.
    • (2004) Comput Methods Biomech Biomed Engin , vol.7 , pp. 51-61
    • Fernandes, P.R.1    Folgardo, J.2    Ruben, R.B.3
  • 12
    • 33745340382 scopus 로고    scopus 로고
    • Three-dimensional computer-aided design based design sensitivity analysis and shape optimization of the stem using adaptive p-method
    • Tanino H, Ito H, Higa M, etal. Three-dimensional computer-aided design based design sensitivity analysis and shape optimization of the stem using adaptive p-method. J Biomech 2006;39:1948-53.
    • (2006) J Biomech , vol.39 , pp. 1948-1953
    • Tanino, H.1    Ito, H.2    Higa, M.3
  • 13
    • 0031043430 scopus 로고    scopus 로고
    • Factors affecting cement strains near the tip of a cemented femoral component
    • Estok DM, Orr TE, Harris WH. Factors affecting cement strains near the tip of a cemented femoral component. J Arthrop 1997;12-1:40-8.
    • (1997) J Arthrop , vol.12 , Issue.1 , pp. 40-48
    • Estok, D.M.1    Orr, T.E.2    Harris, W.H.3
  • 14
    • 0034890301 scopus 로고    scopus 로고
    • Dependency of cement mantle thickness on femoral stem design and centralizer
    • Breusch SJ, Lukoschek M, Kreutzer J, Brocai D, Gruen TA. Dependency of cement mantle thickness on femoral stem design and centralizer. J Arthrop 2001;16-5:648-57.
    • (2001) J Arthrop , vol.16 , Issue.5 , pp. 648-657
    • Breusch, S.J.1    Lukoschek, M.2    Kreutzer, J.3    Brocai, D.4    Gruen, T.A.5
  • 15
    • 3343006998 scopus 로고    scopus 로고
    • Cement microcracks in thin-mantle regions after in vitro fatigue loading
    • Mann KA, Gupta S, Race A, Miller MA, Cleary RJ, Ayers DC. Cement microcracks in thin-mantle regions after in vitro fatigue loading. J Arthrop 2004;19-5:605-12.
    • (2004) J Arthrop , vol.19 , Issue.5 , pp. 605-612
    • Mann, K.A.1    Gupta, S.2    Race, A.3    Miller, M.A.4    Cleary, R.J.5    Ayers, D.C.6
  • 16
    • 0025985513 scopus 로고
    • Mechanical characteristics of the stem-cement inteface
    • Mann KA, Bartel DL, etal. Mechanical characteristics of the stem-cement inteface. J Orthop Res 1991;9:798-808.
    • (1991) J Orthop Res , vol.9 , pp. 798-808
    • Mann, K.A.1    Bartel, D.L.2
  • 17
    • 0036918429 scopus 로고    scopus 로고
    • Stair climbing is more detrimental to the cement in hip replacement than walking
    • Stolk J, Verdonschot N, Huiskes R. Stair climbing is more detrimental to the cement in hip replacement than walking. Clin Orthop 2002;405:294-305.
    • (2002) Clin Orthop , vol.405 , pp. 294-305
    • Stolk, J.1    Verdonschot, N.2    Huiskes, R.3
  • 18
    • 79954987115 scopus 로고    scopus 로고
    • Neighborhood cultivation genetic algorithm for multi-objective optimization problems
    • No.SIG10 (TOM7)
    • Watanabe S, Hiroyasu T, etal. Neighborhood cultivation genetic algorithm for multi-objective optimization problems. IPSJ J 2002;43:No.SIG10 (TOM7);183-98.
    • (2002) IPSJ J , vol.43 , pp. 183-198
    • Watanabe, S.1    Hiroyasu, T.2
  • 19
    • 0027691265 scopus 로고
    • From structure to process, from organ to cell: recent developments of FE-analysis in orthopaedic biomechanics
    • Huiskes R, Hollister SJ. From structure to process, from organ to cell: recent developments of FE-analysis in orthopaedic biomechanics. Trans ASME J Biomech Engin 1993;115:520-27.
    • (1993) Trans ASME J Biomech Engin , vol.115 , pp. 520-527
    • Huiskes, R.1    Hollister, S.J.2
  • 20
    • 0034984126 scopus 로고    scopus 로고
    • Hip contact forces and gait patterns from routine activities
    • Bergmann G, Deuretzbacher G, Heller M, etal. Hip contact forces and gait patterns from routine activities. J Biomech 2001;34:859-72.
    • (2001) J Biomech , vol.34 , pp. 859-872
    • Bergmann, G.1    Deuretzbacher, G.2    Heller, M.3
  • 21
    • 0029112497 scopus 로고
    • Early loosening of the femoral component at the cement-prosthesis interface after total hip replacement
    • Mohler CG, Callaghan JJ, Collis DK, Johnston RC. Early loosening of the femoral component at the cement-prosthesis interface after total hip replacement. J Bone Joint Surg 1995;77-A:1315-22.
    • (1995) J Bone Joint Surg , vol.77 A , pp. 1315-1322
    • Mohler, C.G.1    Callaghan, J.J.2    Collis, D.K.3    Johnston, R.C.4
  • 22


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.