메뉴 건너뛰기




Volumn 60, Issue 2, 2011, Pages 135-138

Prehospital airway management of laryngeal tubes : Should the laryngeal tube S with gastric drain tube be preferred in emergency medicine?;Präklinische Anwendung des Larynxtubus : Bietet der Larynxtubus S mit Magensonde Vorteile in der Notfallmedizin?

Author keywords

Airway; Aspiration; Emergency medicine; Gastric drain tube; Laryngeal tube

Indexed keywords

ANESTHETIC EQUIPMENT; ARTICLE; CASE REPORT; EMERGENCY CARE; GASTRIC DRAIN TUBE; HUMAN; LARYNGEAL TUBE; LUNG COMPLIANCE; PULMONARY ASPIRATION; RESPIRATION CONTROL; STOMACH DISEASE; STOMACH OVERINFLATION; TUBE;

EID: 79954629133     PISSN: 00032417     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00101-010-1774-y     Document Type: Article
Times cited : (18)

References (14)
  • 1
    • 76249129687 scopus 로고    scopus 로고
    • The C-MAC videolaryngoscope: First experiences with a new device for videolaryngoscopy-guided intubation
    • Cavus E, Kieckhaefer J, Doerges V et al (2010) The C-MAC videolaryngoscope: first experiences with a new device for videolaryngoscopy- guided intubation. Anesth Analg 110:473-477
    • (2010) Anesth Analg , vol.110 , pp. 473-477
    • Cavus, E.1    Kieckhaefer, J.2    Doerges, V.3
  • 4
    • 0000510723 scopus 로고    scopus 로고
    • Einsatz des Larynx-Tubus bei einem polytraumatisierten Patienten
    • DOI 10.1007/s100490170018
    • Finteis T, Genzwürker H, Becker FS, Ellinger K (2001) Einsatz des Larynxtubus bei einem polytraumatisierten Patienten. Notfall Rettungsmed 4:511-514 (Pubitemid 33365113)
    • (2001) Notfall & Rettungsmedizin , vol.4 , Issue.7 , pp. 511-514
    • Finteis, T.1    Genzwurker, H.2    Becker, F.S.3    Ellinger, K.4
  • 5
    • 3342958868 scopus 로고    scopus 로고
    • A randomized controlled trial comparing the ProSeal™ laryngeal mask airway with the laryngeal tube suction in mechanically ventilated patients
    • DOI 10.1097/00000542-200408000-00011
    • Gaitini LA, Vaida SJ, Somri M et al (2004) A randomized controlled trial comparing the ProSeal laryngeal mask airway with the laryngeal tube suction in mechanically ventilated patients. Anesthesiology 101:316-320 (Pubitemid 38988486)
    • (2004) Anesthesiology , vol.101 , Issue.2 , pp. 316-320
    • Gaitini, L.A.1    Vaida, S.J.2    Somri, M.3    Yanovski, B.4    Ben-David, B.5    Hagberg, C.A.6
  • 6
    • 26244434708 scopus 로고    scopus 로고
    • Lower esophageal sphincter pressure measurement during cardiac arrest in humans: Potential implications for ventilation of the unprotected airway
    • DOI 10.1097/00000542-200510000-00031
    • Gabrielli A, Wenzel V, Layon AJ et al (2005) Lower esophageal sphincter pressure measurement during cardiac arrest in humans: potential implication for ventilation of the unprotected airway. Anesthesiology 103:897-899 (Pubitemid 41415539)
    • (2005) Anesthesiology , vol.103 , Issue.4 , pp. 897-899
    • Gabrielli, A.1    Wenzel, V.2    Layon, A.J.3    Von Goedecke, A.4    Verne, N.G.5    Idris, A.H.6
  • 7
    • 0036176297 scopus 로고    scopus 로고
    • Use of the laryngeal tube for out-of-hospital resuscitation
    • DOI 10.1016/S0300-9572(01)00472-5, PII S0300957201004725
    • Genzwuerker HV, Dhonau S, Ellinger K (2002) Use of the laryngeal tube for out-of-hospital resuscitation. Resuscitation 52:221-224 (Pubitemid 34159034)
    • (2002) Resuscitation , vol.52 , Issue.2 , pp. 221-224
    • Genzwuerker, H.V.1    Dhonau, S.2    Ellinger, K.3
  • 8
    • 48949119081 scopus 로고    scopus 로고
    • Randomized prospective study comparing the laryngeal tube suction II with the ProSeal laryngeal mask airway in anesthetized and paralyzed patients
    • Kikuchi T, Kamiya Y, Ohtsuka T et al (2008) Randomized prospective study comparing the laryngeal tube suction II with the ProSeal laryngeal mask airway in anesthetized and paralyzed patients. Anesthesiology 109:54-60
    • (2008) Anesthesiology , vol.109 , pp. 54-60
    • Kikuchi, T.1    Kamiya, Y.2    Ohtsuka, T.3
  • 9
    • 0036784844 scopus 로고    scopus 로고
    • A comparison of the laryngeal tube with the laryngeal mask airway during routine surgical procedures
    • Ocker H, Wenzel V, Schmucker P et al (2000) A comparison of the laryngeal tube with the laryngeal mask airway during routine surgical procedures. Anesth Analg 95:1094-1097
    • (2000) Anesth Analg , vol.95 , pp. 1094-1097
    • Ocker, H.1    Wenzel, V.2    Schmucker, P.3
  • 10
    • 77951917486 scopus 로고    scopus 로고
    • Out-of-hospital airway management by paramedics and emergency physicians using laryngeal tubes
    • Schalk R, Byhahn C, Fausel F et al (2010) Out-of-hospital airway management by paramedics and emergency physicians using laryngeal tubes. Resuscitation 81:323-326
    • (2010) Resuscitation , vol.81 , pp. 323-326
    • Schalk, R.1    Byhahn, C.2    Fausel, F.3
  • 11
    • 77952323211 scopus 로고    scopus 로고
    • Larynxtubus Suction. Temporäres Hilfsmittel bei Notfallpatienten mit schwierigem Atemweg
    • Scheller B, Walcher F, Byhahn C et al (2010) Larynxtubus Suction. Temporäres Hilfsmittel bei Notfallpatienten mit schwierigem Atemweg. Anaesthesist 59:210-216
    • (2010) Anaesthesist , vol.59 , pp. 210-216
    • Scheller, B.1    Walcher, F.2    Byhahn, C.3
  • 12
    • 3042833661 scopus 로고    scopus 로고
    • Pra"klinische Sicherung der Atemwege. Erfolgsraten und Komplikationen
    • Thierbach A, Piepho T, Wolcke B et al (2004) Präklinische Sicherung der Atemwege. Erfolgsraten und Komplikationen. Anaesthesist 53:543-550 (Pubitemid 38879511)
    • (2004) Anaesthesist , vol.53 , Issue.6 , pp. 543-550
    • Thierbach, A.1    Piepho, T.2    Wolcke, B.3    Kuster, S.4    Dick, W.5
  • 14
    • 0031722709 scopus 로고    scopus 로고
    • Respiratory system compliance decreases after cardiopulmonary resuscitation and stomach inflation: Impact of large and small tidal volumes on calculated peak airway pressure
    • DOI 10.1016/S0300-9572(98)00095-1, PII S0300957298000951
    • Wenzel V, Idris AH, Banner MJ et al (1998) Respiratory system compliance decreases after cardiopulmonary resuscitation and stomach inflation: impact of large and small tidal volumes on calculated peak airway pressure. Resuscitation 38:113-118 (Pubitemid 28491347)
    • (1998) Resuscitation , vol.38 , Issue.2 , pp. 113-118
    • Wenzel, V.1    Idris, A.H.2    Banner, M.J.3    Kubilis, P.S.4    Band, R.5    Williams Jr., J.L.6    Lindner, K.H.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.