메뉴 건너뛰기




Volumn 33, Issue 3, 2011, Pages 272-280

Evaluation of activated partial thromboplastin time (aPTT) reagents for application in biomedical diagnostic device development

Author keywords

APTT; Clotting time; Heparin sensitivity; Stability; Thrombin generation

Indexed keywords

HEPARIN; KAOLIN; PHOSPHOLIPID; REAGENT; SILICON DIOXIDE; THROMBIN;

EID: 79954590457     PISSN: 17515521     EISSN: 1751553X     Source Type: Journal    
DOI: 10.1111/j.1751-553X.2010.01283.x     Document Type: Article
Times cited : (2)

References (31)
  • 1
    • 0019301750 scopus 로고
    • Laboratory monitoring of heparin therapy - The effect of different salts of heparin on the Activated Partial Thromboplastin Time - An analysis of the 1978 and 1979 CAP hematology survey
    • Banez E.I., Triplett D.A. & Koepke J. (1980) Laboratory monitoring of heparin therapy - The effect of different salts of heparin on the Activated Partial Thromboplastin Time - An analysis of the 1978 and 1979 CAP hematology survey. American Journal of Clinical Pathology 74, 569-574.
    • (1980) American Journal of Clinical Pathology , vol.74 , pp. 569-574
    • Banez, E.I.1    Triplett, D.A.2    Koepke, J.3
  • 3
    • 0027517937 scopus 로고
    • Use of the Activated Clotting Time in anticoagulation monitoring of intravascular procedures
    • Bowers J. & Ferguson J.J. (1993) Use of the Activated Clotting Time in anticoagulation monitoring of intravascular procedures. Texas Heart Institute Journal 20, 258-263.
    • (1993) Texas Heart Institute Journal , vol.20 , pp. 258-263
    • Bowers, J.1    Ferguson, J.J.2
  • 4
    • 0027978049 scopus 로고
    • Assembly of the prothrombinase complex on lipid vesicles depends on the stereochemical configuration of the polar headgroup of phosphatidylserine
    • Comfurius P., Smeets E.F., Willems G.M., Bevers E.M. & Zwaal R.F.A. (1994) Assembly of the prothrombinase complex on lipid vesicles depends on the stereochemical configuration of the polar headgroup of phosphatidylserine. Biochemistry 33, 10319-10324.
    • (1994) Biochemistry , vol.33 , pp. 10319-10324
    • Comfurius, P.1    Smeets, E.F.2    Willems, G.M.3    Bevers, E.M.4    Zwaal, R.F.A.5
  • 6
    • 0030799555 scopus 로고    scopus 로고
    • Standardization of APTT reagents for heparin therapy monitoring: urgent or fading priority?
    • Eby C. (1997) Standardization of APTT reagents for heparin therapy monitoring: urgent or fading priority? Clinical Chemistry 43, 1105-1107.
    • (1997) Clinical Chemistry , vol.43 , pp. 1105-1107
    • Eby, C.1
  • 7
    • 0023218138 scopus 로고
    • The effects of heparin on the Activated Partial Thromboplastin Time of the College of American Pathologists survey specimens - Responsiveness, precision and sample effects
    • Gawoski J.M., Arkin C.F., Bovill T., Brandt J., Rock W.A & Triplett D.A. (1987) The effects of heparin on the Activated Partial Thromboplastin Time of the College of American Pathologists survey specimens - Responsiveness, precision and sample effects. Archives of Pathology & Laboratory Medicine 111, 785-790.
    • (1987) Archives of Pathology & Laboratory Medicine , vol.111 , pp. 785-790
    • Gawoski, J.M.1    Arkin, C.F.2    Bovill, T.3    Brandt, J.4    Rock, W.A.5    Triplett, D.A.6
  • 8
    • 0018687525 scopus 로고
    • Recent advances in the understanding of the contact activation reactions
    • Griffin J.H. & Cochrane C.G. (1979) Recent advances in the understanding of the contact activation reactions. Seminars in Thrombosis and Hemostasis 5, 254-273.
    • (1979) Seminars in Thrombosis and Hemostasis , vol.5 , pp. 254-273
    • Griffin, J.H.1    Cochrane, C.G.2
  • 10
    • 79954589489 scopus 로고    scopus 로고
    • Point-of-care INR monitoring devices for patients on long-term oral anticoagulation therapy
    • Khan T. (2009) Point-of-care INR monitoring devices for patients on long-term oral anticoagulation therapy. Value in Health 12, A142.
    • (2009) Value in Health , vol.12
    • Khan, T.1
  • 11
    • 0030057043 scopus 로고    scopus 로고
    • Wide variability in the sensitivity of APTT reagents for monitoring of heparin dosage
    • Kitchen S., Jennings I., Woods T.A.L. & Preston F.E. (1996) Wide variability in the sensitivity of APTT reagents for monitoring of heparin dosage. Journal of Clinical Pathology 49, 10-14.
    • (1996) Journal of Clinical Pathology , vol.49 , pp. 10-14
    • Kitchen, S.1    Jennings, I.2    Woods, T.A.L.3    Preston, F.E.4
  • 15
    • 0032433948 scopus 로고    scopus 로고
    • Evaluation of the activated partial thromboplastin time (APTT) sensitivity to heparin using five commercial reagents: implications for therapeutic monitoring
    • Manzato F., Mengoni A., Grilenzoni A. & Lippi G. (1998) Evaluation of the activated partial thromboplastin time (APTT) sensitivity to heparin using five commercial reagents: implications for therapeutic monitoring. Clinical Chemistry and Laboratory Medicine 36, 975-980.
    • (1998) Clinical Chemistry and Laboratory Medicine , vol.36 , pp. 975-980
    • Manzato, F.1    Mengoni, A.2    Grilenzoni, A.3    Lippi, G.4
  • 17
    • 0026642493 scopus 로고
    • The preparation of a sensitive Partial Thromboplastin reagent from bovine brain
    • Martin B.A., Branch D.W. & Rodgers G.M. (1992) The preparation of a sensitive Partial Thromboplastin reagent from bovine brain. Blood Coagulation & Fibrinolysis 3, 287-294.
    • (1992) Blood Coagulation & Fibrinolysis , vol.3 , pp. 287-294
    • Martin, B.A.1    Branch, D.W.2    Rodgers, G.M.3
  • 18
    • 79954572783 scopus 로고
    • APTT in a collective of plasmas from normal healthy individuals - Comparison of Dapttin with other aPTT reagents
    • Moritz B. & Lang H. (1995) APTT in a collective of plasmas from normal healthy individuals - Comparison of Dapttin with other aPTT reagents. Thrombosis and Haemostasis 73, 1243.
    • (1995) Thrombosis and Haemostasis , vol.73 , pp. 1243
    • Moritz, B.1    Lang, H.2
  • 19
    • 2942516380 scopus 로고    scopus 로고
    • Usefulness of synthetic phospholipid in measurement of activated partial thromboplastin time: a new preparation procedure to reduce batch difference
    • Okuda M. & Yamamoto Y. (2004) Usefulness of synthetic phospholipid in measurement of activated partial thromboplastin time: a new preparation procedure to reduce batch difference. Clinical and Laboratory Haematology 26, 215-223.
    • (2004) Clinical and Laboratory Haematology , vol.26 , pp. 215-223
    • Okuda, M.1    Yamamoto, Y.2
  • 21
    • 0042626398 scopus 로고    scopus 로고
    • Comparison of four commercially available activated partial thromboplastin time reagents using a semi-automated coagulometer
    • Shetty S., Ghosh K. & Mohanty D. (2003) Comparison of four commercially available activated partial thromboplastin time reagents using a semi-automated coagulometer. Blood Coagulation & Fibrinolysis 14, 493-497.
    • (2003) Blood Coagulation & Fibrinolysis , vol.14 , pp. 493-497
    • Shetty, S.1    Ghosh, K.2    Mohanty, D.3
  • 22
    • 0018948135 scopus 로고
    • Procoagulant activity of Partial Thromboplastin (cephalin) reagent and its phospholipid composition
    • Slater P.J., Stevenson K.J. & Poller L. (1980) Procoagulant activity of Partial Thromboplastin (cephalin) reagent and its phospholipid composition. Thrombosis Research 18, 831-838.
    • (1980) Thrombosis Research , vol.18 , pp. 831-838
    • Slater, P.J.1    Stevenson, K.J.2    Poller, L.3
  • 23
    • 79954604972 scopus 로고
    • The chemical composition, ultrastructure and procoagulant properties of 5 new aPTT reagents
    • Stevenson K.J., Poller L. & Thomson J.M. (1991) The chemical composition, ultrastructure and procoagulant properties of 5 new aPTT reagents. Thrombosis and Haemostasis 65, 906.
    • (1991) Thrombosis and Haemostasis , vol.65 , pp. 906
    • Stevenson, K.J.1    Poller, L.2    Thomson, J.M.3
  • 24
    • 0344961471 scopus 로고
    • Partial Thromboplastin Time (Cephalin Time) in anticoagulation therapy
    • Struver G.P. & Bittner D.L. (1962) Partial Thromboplastin Time (Cephalin Time) in anticoagulation therapy. American Journal of Clinical Pathology 38, 473-478.
    • (1962) American Journal of Clinical Pathology , vol.38 , pp. 473-478
    • Struver, G.P.1    Bittner, D.L.2
  • 26
    • 0025174959 scopus 로고
    • Monitoring heparin therapy - Relationships between the Activated Partial Thromboplastin Time and heparin assays based on ex vivo heparin samples
    • Van den Besselaar A., Meeuwissebraun J. & Bertina R.M. (1990) Monitoring heparin therapy - Relationships between the Activated Partial Thromboplastin Time and heparin assays based on ex vivo heparin samples. Thrombosis and Haemostasis 63, 16-23.
    • (1990) Thrombosis and Haemostasis , vol.63 , pp. 16-23
    • Van den Besselaar, A.1    Meeuwissebraun, J.2    Bertina, R.M.3
  • 27
    • 0030836719 scopus 로고    scopus 로고
    • Preparation of lyophilized partial thromboplastin time reagent composed of synthetic phospholipids: usefulness for monitoring heparin therapy
    • Van den Besselaar A., Neuteboom J., Meeuwissebraun J. & Bertina R.M. (1997) Preparation of lyophilized partial thromboplastin time reagent composed of synthetic phospholipids: usefulness for monitoring heparin therapy. Clinical Chemistry 43, 1215-1222.
    • (1997) Clinical Chemistry , vol.43 , pp. 1215-1222
    • Van den Besselaar, A.1    Neuteboom, J.2    Meeuwissebraun, J.3    Bertina, R.M.4
  • 28
    • 50049135947 scopus 로고    scopus 로고
    • Thrombin generation testing in routine clinical practice: are we there yet?
    • Van Veen J.J., Gatt A. & Makris M. (2008) Thrombin generation testing in routine clinical practice: are we there yet? British Journal of Haematology 142, 889-903.
    • (2008) British Journal of Haematology , vol.142 , pp. 889-903
    • Van Veen, J.J.1    Gatt, A.2    Makris, M.3
  • 29
    • 11044227414 scopus 로고    scopus 로고
    • Thrombin generation assay and other universal tests for monitoring haemophilia therapy
    • Varadi K., Turecek P.L. & Schwarz H.P. (2004) Thrombin generation assay and other universal tests for monitoring haemophilia therapy. Haemophilia 10, 17-21.
    • (2004) Haemophilia , vol.10 , pp. 17-21
    • Varadi, K.1    Turecek, P.L.2    Schwarz, H.P.3
  • 31
    • 33947391753 scopus 로고    scopus 로고
    • Thrombin generation assays: understanding how the method influences the results
    • Wolberg A.S. (2007) Thrombin generation assays: understanding how the method influences the results. Thrombosis Research 119, 663-665.
    • (2007) Thrombosis Research , vol.119 , pp. 663-665
    • Wolberg, A.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.