Evaluation of imaging performance of major image guidance systems

Author keywords

Cone beam CT; IGRT; Image quality; MVCT; Tomotherapy

Indexed keywords

ARTICLE; COMPUTER ASSISTED RADIOTHERAPY; CONE BEAM COMPUTED TOMOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; IMAGE ENHANCEMENT; IMAGE QUALITY; IMAGE RECONSTRUCTION; IMAGING SYSTEM; INSTRUMENT VALIDATION; INTERMETHOD COMPARISON; RADIATION DOSE; REPRODUCIBILITY; SIGNAL NOISE RATIO; TOMOTHERAPY;

EID: 79954530572     PISSN: None     EISSN: 18235530     Source Type: Journal    
DOI: 10.2349/biij.7.2.e11     Document Type: Article
Times cited : (35)

References (16)
  • 1
    • 0035989949 scopus 로고    scopus 로고
    • A performance comparison of flat-panel imager-based MV and kV cone-beam CT
    • Groh B, Siewerdsen J, Drake D, et al. A performance comparison of flat-panel imager-based MV and kV cone-beam CT. Med Phys 2002; 29: 967-75.
    • (2002) Med Phys , vol.29 , pp. 967-975
    • Groh, B.1    Siewerdsen, J.2    Drake, D.3
  • 2
    • 33745791393 scopus 로고    scopus 로고
    • Comparison of image performance between cone-beam computed tomography for dental use and four-row multidetector helical CT
    • Hashimoto K, Kawashima S, Araki M, et al. Comparison of image performance between cone-beam computed tomography for dental use and four-row multidetector helical CT. J Oral Science 2006; 48(1): 27-34.
    • (2006) J Oral Science , vol.48 , Issue.1 , pp. 27-34
    • Hashimoto, K.1    Kawashima, S.2    Araki, M.3
  • 3
    • 41949096847 scopus 로고    scopus 로고
    • Comparison of cone beam computed tomography imaging with physical measures
    • Stratemann S, Huang J, Maki K, et al. Comparison of cone beam computed tomography imaging with physical measures. Dentomaxillofac Radiol 2008; 37(2): 80-93.
    • (2008) Dentomaxillofac Radiol , vol.37 , Issue.2 , pp. 80-93
    • Stratemann, S.1    Huang, J.2    Maki, K.3
  • 4
    • 36649025436 scopus 로고    scopus 로고
    • Point/Counterpoint Kilovoltage imaging is more suitable than megavoltage imaging for guiding radiation therapy. Med
    • Xing L, Chang L, Orton C. Point/Counterpoint Kilovoltage imaging is more suitable than megavoltage imaging for guiding radiation therapy. Med. Phys 2007; 34(12): 4563-4566.
    • (2007) Phys , vol.34 , Issue.12 , pp. 4563-4566
    • Xing, L.1    Chang, L.2    Orton, C.3
  • 5
    • 69649105188 scopus 로고    scopus 로고
    • Task Group 142 report: Quality assurance of medical accelerators. Med
    • Klein EE, Hanley J, Bayouth J, et al. Task Group 142 report: Quality assurance of medical accelerators. Med. Phys 2009; 36(9): 4197-4212.
    • (2009) Phys , vol.36 , Issue.9 , pp. 4197-4212
    • Klein, E.E.1    Hanley, J.2    Bayouth, J.3
  • 6
    • 77956323953 scopus 로고    scopus 로고
    • QA for helical tomotherapy: Report of the AAPM Task Group 148
    • Langen KM, Papanikolaou N, Balog J, et al. QA for helical tomotherapy: Report of the AAPM Task Group 148. Med Phys 2010; 37(9): 4817-4853.
    • (2010) Med Phys , vol.37 , Issue.9 , pp. 4817-4853
    • Langen, K.M.1    Papanikolaou, N.2    Balog, J.3
  • 7
    • 23944457557 scopus 로고    scopus 로고
    • Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit
    • Meeks S, Harmon J, Langen K, et al. Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit. Med Phys 2005; 32(8): 2673-2681.
    • (2005) Med Phys , vol.32 , Issue.8 , pp. 2673-2681
    • Meeks, S.1    Harmon, J.2    Langen, K.3
  • 8
    • 34547492914 scopus 로고    scopus 로고
    • Commissioning and clinical implementation of a mega-voltage cone beam CT system for treatment localization
    • Gayou O and Miften M. Commissioning and clinical implementation of a mega-voltage cone beam CT system for treatment localization. Med Phys 2007; 34(8): 3183-3192.
    • (2007) Med Phys , vol.34 , Issue.8 , pp. 3183-3192
    • Gayou, O.1    Miften, M.2
  • 9
    • 23844501155 scopus 로고    scopus 로고
    • Soft tissue visualization using a highly efficient megavoltage cone beam CT imaging system
    • Proceedings of SPIE Medical Imaging: Physics of Medical Imaging
    • Ghelmansarai F, Bani-Hashemi A, Pouliot J, et al. Soft tissue visualization using a highly efficient megavoltage cone beam CT imaging system. Medical Imaging 2005; Proceedings of SPIE Medical Imaging: Physics of Medical Imaging: 159-70.
    • (2005) Medical Imaging , pp. 159-170
    • Ghelmansarai, F.1    Bani-Hashemi, A.2    Pouliot, J.3
  • 10
    • 79954476640 scopus 로고    scopus 로고
    • A quality assurance procedure to monitor mechanical stability and image quality of an on-board kV cone-beam CT imager
    • Ali I, Lovelock M, LoSasso T, et al. A quality assurance procedure to monitor mechanical stability and image quality of an on-board kV cone-beam CT imager. Med Phys 2006; 33(6): 2282-2283.
    • (2006) Med Phys , vol.33 , Issue.6 , pp. 2282-2283
    • Ali, I.1    Lovelock, M.2    LoSasso, T.3
  • 11
    • 33750568952 scopus 로고    scopus 로고
    • A quality assurance program for the on-board imager
    • Yoo S, Kim G, Hammound R, et al. A quality assurance program for the on-board imager. Med Phys 2006; 33(11): 4431-4447.
    • (2006) Med Phys , vol.33 , Issue.11 , pp. 4431-4447
    • Yoo, S.1    Kim, G.2    Hammound, R.3
  • 12
    • 79954540515 scopus 로고    scopus 로고
    • The utility of megavoltage computed tomotgraphy images from a helical Tomotherapy system for setup verification purposes
    • Forrest L, Mackie T, Ruchala K, et al. The utility of megavoltage computed tomotgraphy images from a helical Tomotherapy system for setup verification purposes. Phys Med Biol 2000; 45; 3545-3562.
    • (2000) Phys Med Biol , vol.45 , pp. 3545-3562
    • Forrest, L.1    Mackie, T.2    Ruchala, K.3
  • 13
    • 10044246031 scopus 로고    scopus 로고
    • The utility of megavoltage computed tomography images from a helical tomotherapy system for setup verification purposes
    • Forrest L, Mackie T, Ruchala K, et al. The utility of megavoltage computed tomography images from a helical tomotherapy system for setup verification purposes. Int J Radiat Oncol Biol Phys 2004; 60(5): 1639-1644.
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , Issue.5 , pp. 1639-1644
    • Forrest, L.1    Mackie, T.2    Ruchala, K.3
  • 14
    • 0034536973 scopus 로고    scopus 로고
    • Megavoltage CT image reconstruction during tomotherapy treatments
    • Ruchala K, Olivera G, Kapatoes J, et al. Megavoltage CT image reconstruction during tomotherapy treatments. Phys Med Biol 2000; 45: 3545-3562.
    • (2000) Phys Med Biol , vol.45 , pp. 3545-3562
    • Ruchala, K.1    Olivera, G.2    Kapatoes, J.3
  • 15
    • 19944432829 scopus 로고    scopus 로고
    • Low-dose megavoltage cone-beam CT for radiation therapy
    • Pouliot J, Bani-Hashemi A, Chen J, et al. Low-dose megavoltage cone-beam CT for radiation therapy. Int J Radiat Oncol Biol Phys 2005; 61(2): 552-560.
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , Issue.2 , pp. 552-560
    • Pouliot, J.1    Bani-Hashemi, A.2    Chen, J.3
  • 16
    • 33644932630 scopus 로고    scopus 로고
    • Megavoltage cone-beam CT: System description and clinical applications
    • Morin O, Gills A, Chen J, et al. Megavoltage cone-beam CT: System description and clinical applications. Med Dosim 2006; 31: 51-61.
    • (2006) Med Dosim , vol.31 , pp. 51-61
    • Morin, O.1    Gills, A.2    Chen, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.