메뉴 건너뛰기




Volumn 98, Issue 2, 2011, Pages 231-233

Slurry sampling and high-resolution continuum source flame atomic absorption spectrometry using secondary lines for the determination of Ca and Mg in dairy products

Author keywords

Calcium; Dairy products; High resolution continuum source flame atomic absorption spectrometry; Magnesium; Secondary lines; Slurry sampling

Indexed keywords


EID: 79954432565     PISSN: 0026265X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.microc.2011.02.005     Document Type: Article
Times cited : (31)

References (22)
  • 1
    • 77955560152 scopus 로고    scopus 로고
    • Determination of the mineral composition of fresh bovine milk from the milk-producing areas located in the State of Sergipe in Brazil and evaluation employing exploratory analysis
    • do Nascimento I.R., de Jesus R.M., dos Santos W.N.L., Souza A.S., Fragoso W.D., dos Reis P.S. Determination of the mineral composition of fresh bovine milk from the milk-producing areas located in the State of Sergipe in Brazil and evaluation employing exploratory analysis. Microchem. J. 2010, 96:37.
    • (2010) Microchem. J. , vol.96 , pp. 37
    • do Nascimento, I.R.1    de Jesus, R.M.2    dos Santos, W.N.L.3    Souza, A.S.4    Fragoso, W.D.5    dos Reis, P.S.6
  • 2
    • 70350645378 scopus 로고    scopus 로고
    • X-ray fluorescence determination of element contents in milk and dairy products
    • Pashkova G.V. X-ray fluorescence determination of element contents in milk and dairy products. Food Anal. Methods 2009, 2:303.
    • (2009) Food Anal. Methods , vol.2 , pp. 303
    • Pashkova, G.V.1
  • 3
    • 46149084900 scopus 로고    scopus 로고
    • Validation, uncertainty estimation and application of a sector field ICP MS-based method for As, Cd and Pb in cow's milk and infant formulas
    • Frazzoli C., Bocca B. Validation, uncertainty estimation and application of a sector field ICP MS-based method for As, Cd and Pb in cow's milk and infant formulas. Microchim. Acta 2008, 162:43.
    • (2008) Microchim. Acta , vol.162 , pp. 43
    • Frazzoli, C.1    Bocca, B.2
  • 5
    • 79951721615 scopus 로고    scopus 로고
    • Direct determination of molybdenum in milk and infant food samples using slurry sampling and graphite furnace atomic absorption spectrometry
    • de Amorim F.R., Franco M.B., Nascentes C.C., da Silva J.B.B. Direct determination of molybdenum in milk and infant food samples using slurry sampling and graphite furnace atomic absorption spectrometry. Food Anal. Methods 2011, 4:41.
    • (2011) Food Anal. Methods , vol.4 , pp. 41
    • de Amorim, F.R.1    Franco, M.B.2    Nascentes, C.C.3    da Silva, J.B.B.4
  • 9
    • 67651091607 scopus 로고    scopus 로고
    • Fast sequential multi-element determination of Ca, Mg, K, Cu, Fe, Mn and Zn for foliar diagnosis using high-resolution continuum source flame atomic absorption spectrometry: feasibility of secondary lines, side pixel registration and least-squares background correction
    • de Oliveira S.R., Raposo J.L., Neto J.A.G. Fast sequential multi-element determination of Ca, Mg, K, Cu, Fe, Mn and Zn for foliar diagnosis using high-resolution continuum source flame atomic absorption spectrometry: feasibility of secondary lines, side pixel registration and least-squares background correction. Spectrochim. Acta B 2009, 64:593.
    • (2009) Spectrochim. Acta B , vol.64 , pp. 593
    • de Oliveira, S.R.1    Raposo, J.L.2    Neto, J.A.G.3
  • 10
    • 77950267282 scopus 로고    scopus 로고
    • Simultaneous determination of cobalt and vanadium in undiluted crude oil using high-resolution continuum source graphite furnace atomic absorption spectrometry
    • Dittert I.M., Silva J.S.A., Araujo R.G.O., Curtius A.J., Welz B., Becker-Ross H. Simultaneous determination of cobalt and vanadium in undiluted crude oil using high-resolution continuum source graphite furnace atomic absorption spectrometry. J. Anal. At. Spectrom. 2010, 25:590.
    • (2010) J. Anal. At. Spectrom. , vol.25 , pp. 590
    • Dittert, I.M.1    Silva, J.S.A.2    Araujo, R.G.O.3    Curtius, A.J.4    Welz, B.5    Becker-Ross, H.6
  • 12
    • 77950194750 scopus 로고    scopus 로고
    • Direct determination of phosphorus in biological samples using a solid sampling-high resolution-continuum source electrothermal spectrometer: comparison of atomic and molecular absorption spectrometry
    • Resano M., Briceno J., Belarra M.A. Direct determination of phosphorus in biological samples using a solid sampling-high resolution-continuum source electrothermal spectrometer: comparison of atomic and molecular absorption spectrometry. J. Anal. At. Spectrom. 2009, 24:1343.
    • (2009) J. Anal. At. Spectrom. , vol.24 , pp. 1343
    • Resano, M.1    Briceno, J.2    Belarra, M.A.3
  • 13
    • 77950627778 scopus 로고    scopus 로고
    • Simultaneous determination of Cd and Fe in sewage sludge by high-resolution continuum source electrothermal atomic absorption spectrometry with slurry sampling
    • Vignola F., Borges D.L.G., Curtius A.J., Welz B., Becker-Ross H. Simultaneous determination of Cd and Fe in sewage sludge by high-resolution continuum source electrothermal atomic absorption spectrometry with slurry sampling. Microchem. J. 2010, 95:333.
    • (2010) Microchem. J. , vol.95 , pp. 333
    • Vignola, F.1    Borges, D.L.G.2    Curtius, A.J.3    Welz, B.4    Becker-Ross, H.5
  • 15
    • 77952099957 scopus 로고    scopus 로고
    • Use of slurry sampling for the direct determination of zinc in yogurt by high resolution-continuum source flame atomic absorption spectrometry
    • Brandao G.C., Jesus R.M., da Silva E.G.P., Ferreira S.L.C. Use of slurry sampling for the direct determination of zinc in yogurt by high resolution-continuum source flame atomic absorption spectrometry. Talanta 2010, 81:1357.
    • (2010) Talanta , vol.81 , pp. 1357
    • Brandao, G.C.1    Jesus, R.M.2    da Silva, E.G.P.3    Ferreira, S.L.C.4
  • 17
    • 75749123000 scopus 로고    scopus 로고
    • Fast multi-element screening of non-digested biological materials by slurry introduction to ICP-AES
    • Kollander B., Andersson M., Pettersson J. Fast multi-element screening of non-digested biological materials by slurry introduction to ICP-AES. Talanta 2010, 80:2068.
    • (2010) Talanta , vol.80 , pp. 2068
    • Kollander, B.1    Andersson, M.2    Pettersson, J.3
  • 18
    • 77955558893 scopus 로고    scopus 로고
    • Development of an analytical approach for determination of total arsenic and arsenic (III) in airborne particulate matter by slurry sampling and HG-FAAS
    • Macedo S.M., dos Santos D.C., de Jesus R.M., da Rocha G.O., Ferreira S.L.C., de Andrade J.B. Development of an analytical approach for determination of total arsenic and arsenic (III) in airborne particulate matter by slurry sampling and HG-FAAS. Microchem. J. 2010, 96:46-49.
    • (2010) Microchem. J. , vol.96 , pp. 46-49
    • Macedo, S.M.1    dos Santos, D.C.2    de Jesus, R.M.3    da Rocha, G.O.4    Ferreira, S.L.C.5    de Andrade, J.B.6
  • 20
    • 77955525215 scopus 로고    scopus 로고
    • Determination of cadmium and lead in plastic material from waste electronic equipment using solid sampling graphite furnace atomic absorption spectrometry
    • Duarte A.T., Dessuy M.B., Silva M.M., Vale M.G.R., Welz B. Determination of cadmium and lead in plastic material from waste electronic equipment using solid sampling graphite furnace atomic absorption spectrometry. Microchem. J. 2010, 96:102.
    • (2010) Microchem. J. , vol.96 , pp. 102
    • Duarte, A.T.1    Dessuy, M.B.2    Silva, M.M.3    Vale, M.G.R.4    Welz, B.5
  • 21
    • 33745253401 scopus 로고    scopus 로고
    • Current status of direct solid sampling for electrothermal atomic absorption spectrometry-a critical review of the development between 1995 and 2005
    • Vale M.G.R., Oleszczuk N., dos Santos W.N.L. Current status of direct solid sampling for electrothermal atomic absorption spectrometry-a critical review of the development between 1995 and 2005. Appl. Spectrosc. Rev. 2006, 41:377.
    • (2006) Appl. Spectrosc. Rev. , vol.41 , pp. 377
    • Vale, M.G.R.1    Oleszczuk, N.2    dos Santos, W.N.L.3
  • 22
    • 0036310862 scopus 로고    scopus 로고
    • Laboratory validation of methods-harmonized guidelines
    • Thompson M., Ellison S.L.R., Wood R. Laboratory validation of methods-harmonized guidelines. Pure Appl. Chem. 2002, 74:835.
    • (2002) Pure Appl. Chem. , vol.74 , pp. 835
    • Thompson, M.1    Ellison, S.L.R.2    Wood, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.