메뉴 건너뛰기




Volumn 11, Issue 4, 2011, Pages 316-323

Risk of internal carotid artery injury during C1 screw placement: Analysis of 160 computed tomography angiograms

Author keywords

C1 lateral mass screw placement; Complication; Internal carotid artery; Transarticular C1 C2 screw placement; Vascular injury

Indexed keywords

ADULT; AGED; ARTICLE; BONE SCREW; CAROTID ARTERIOGRAPHY; CAROTID ARTERY INJURY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FEMALE; FLUOROSCOPY; HUMAN; INTERNAL CAROTID ARTERY; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; RADIOGRAPHY; RISK ASSESSMENT;

EID: 79953844018     PISSN: 15299430     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.spinee.2011.03.009     Document Type: Article
Times cited : (19)

References (21)
  • 1
    • 2442579305 scopus 로고    scopus 로고
    • Anatomic relationship of the internal carotid artery to the C1 vertebra: A case report of cervical reconstruction for chordoma and pilot study to assess the risk of screw fixation of the atlas
    • Currier BL, Todd LT, Maus TP, et al. Anatomic relationship of the internal carotid artery to the C1 vertebra: a case report of cervical reconstruction for chordoma and pilot study to assess the risk of screw fixation of the atlas. Spine 2003;28:E461-7.
    • (2003) Spine , vol.28
    • Currier, B.L.1    Todd, L.T.2    Maus, T.P.3
  • 2
    • 34247526494 scopus 로고    scopus 로고
    • Iatrogenic perforation of the internal carotid artery by a transarticular screw: An unusual case of repetitive ischemic stroke
    • DOI 10.1016/j.clineuro.2007.02.008, PII S0303846707000492
    • Bogaerde MV, Viaene P, Thijs V. Iatrogenic perforation of the internal carotid artery by transarticular screw: an unusual case of repetitive ischemic stroke. Clin Neurol Neurosurg 2007;109:466-9. (Pubitemid 46660334)
    • (2007) Clinical Neurology and Neurosurgery , vol.109 , Issue.5 , pp. 466-469
    • Bogaerde, M.V.1    Viaene, P.2    Thijs, V.3
  • 3
    • 41349107181 scopus 로고    scopus 로고
    • Relationship of the internal carotid artery to the anterior aspect of the C1 vertebra: Implications for C1-C2 transarticular and C1 lateral mass fixation
    • DOI 10.1097/BRS.0b013e318166e083, PII 0000763220080315000011
    • Currier BL, Maus TP, Eck JC, et al. Relationship of the internal carotid artery to the anterior aspect of the C1 vertebra: implications for C1-C2 transarticular and C1 lateral mass fixation. Spine 2008;33:635-9. (Pubitemid 351451725)
    • (2008) Spine , vol.33 , Issue.6 , pp. 635-639
    • Currier, B.L.1    Maus, T.P.2    Eck, J.C.3    Larson, D.R.4    Yaszemski, M.J.5
  • 4
    • 41749124565 scopus 로고    scopus 로고
    • Anatomical relationship of the internal carotid artery to C-1: Clinical implications for screw fixation of the atlas
    • DOI 10.3171/SPI/2008/8/4/335
    • Hoh DJ, Maya M, Jung A, et al. Anatomical relationship of the internal carotid artery to C-1: clinical implications for screw fixation of the atlas. J Neurosurg Spine 2008;8:335-40. (Pubitemid 351489558)
    • (2008) Journal of Neurosurgery: Spine , vol.8 , Issue.4 , pp. 335-340
    • Hoh, D.J.1    Maya, M.2    Jung, A.3    Ponrartana, S.4    Lauryssen, C.L.5
  • 5
    • 58949095488 scopus 로고    scopus 로고
    • Relationship between screw trajectory of C1 lateral mass screw and internal carotid artery
    • Murakami S, Mizutani J, Fukuoka M, et al. Relationship between screw trajectory of C1 lateral mass screw and internal carotid artery. Spine 2008;33:2581-5.
    • (2008) Spine , vol.33 , pp. 2581-2585
    • Murakami, S.1    Mizutani, J.2    Fukuoka, M.3
  • 6
    • 34249794838 scopus 로고    scopus 로고
    • The use of C1 lateral mass screws in complex cervical spine surgery: Indications, techniques, and outcome in a prospective consecutive series of 25 cases
    • DOI 10.1097/01.bsd.0000211291.21766.4d, PII 0002472020070600000009
    • Gunnarsson T, Massicotte EM, Govender PV, et al. The use of C1 lateral mass screws in complex cervical spine surgery: indications, techniques, and outcome in a prospective consecutive series of 25 cases. J Spinal Disord Tech 2007;20:308-16. (Pubitemid 46849992)
    • (2007) Journal of Spinal Disorders and Techniques , vol.20 , Issue.4 , pp. 308-316
    • Gunnarsson, T.1    Massicotte, E.M.2    Govender, P.V.3    Raja, R.Y.4    Fehlings, M.G.5
  • 7
    • 24944496817 scopus 로고    scopus 로고
    • Iatrogenic carotid artery injury in neurosurgery
    • DOI 10.1007/s10143-005-0412-7
    • Inamasu J, Guiot BH. Iatrogenic carotid artery injury in neurosurgery. Neurosurg Rev 2005;28:239-47. (Pubitemid 41317893)
    • (2005) Neurosurgical Review , vol.28 , Issue.4 , pp. 239-247
    • Inamasu, J.1    Guiot, B.H.2
  • 8
    • 33645108803 scopus 로고    scopus 로고
    • Vascular injury and complication in neurosurgical spine surgery
    • Wien
    • Inamasu J, Guiot BH. Vascular injury and complication in neurosurgical spine surgery. Acta Neurochir (Wien) 2006;148:375-87.
    • (2006) Acta Neurochir , vol.148 , pp. 375-387
    • Inamasu, J.1    Guiot, B.H.2
  • 9
    • 0034128001 scopus 로고    scopus 로고
    • The optimal transarticular C1-2 screw length and the location of the hypoglossal nerve
    • DOI 10.1016/S0090-3019(00)00160-9, PII S0090301900001609
    • Ebraheim NA, Misson JR, Xu R, Yeasting RA. The optimal transarticular C1-2 screw length and the location of the hypoglossal nerve. Surg Neurol 2000;53:208-10. (Pubitemid 30201523)
    • (2000) Surgical Neurology , vol.53 , Issue.3 , pp. 208-210
    • Ebraheim, N.A.1    Misson, J.R.2    Xu, R.3    Yeasting, R.A.4
  • 10
    • 34548252787 scopus 로고    scopus 로고
    • Hypoglossal nerve palsy after posterior screw placement on the C-1 lateral mass. Case report
    • Hong JT, Lee SW, Son BC, et al. Hypoglossal nerve palsy after posterior screw placement on the C-1 lateral mass. Case report. J Neurosurg Spine 2006;5:83-5.
    • (2006) J Neurosurg Spine , vol.5 , pp. 83-85
    • Hong, J.T.1    Lee, S.W.2    Son, B.C.3
  • 11
    • 67649784066 scopus 로고    scopus 로고
    • Lateral fluoroscopic guide to prevent occipitocervical and atlantoaxial joint violation during C1 lateral mass screw placement
    • Yeom JS, Buchowski JM, Park KW, et al. Lateral fluoroscopic guide to prevent occipitocervical and atlantoaxial joint violation during C1 lateral mass screw placement. Spine J 2009;9:574-9.
    • (2009) Spine J , vol.9 , pp. 574-579
    • Yeom, J.S.1    Buchowski, J.M.2    Park, K.W.3
  • 12
    • 0034866583 scopus 로고    scopus 로고
    • Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement
    • Bloch O, Holly LT, Park J, et al. Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement. J Neurosurg 2001;95(1 Suppl):74-9.
    • (2001) J Neurosurg , vol.95 , Issue.1 SUPPL. , pp. 74-79
    • Bloch, O.1    Holly, L.T.2    Park, J.3
  • 14
    • 0034659356 scopus 로고    scopus 로고
    • Morphologic considerations of C2 isthmus dimensions for the placement of transarticular screws
    • DOI 10.1097/00007632-200006150-00014
    • Mandel IM, Kambach BJ, Petersilge CA, et al. Morphologic considerations of C2 isthmus dimensions for the placement of transarticular screws. Spine 2000;25:1542-7. (Pubitemid 30418469)
    • (2000) Spine , vol.25 , Issue.12 , pp. 1542-1547
    • Mandel, I.M.1    Kambach, B.J.2    Petersilge, C.A.3    Johnstone, B.4    Yoo, J.U.5
  • 15
    • 0037385343 scopus 로고    scopus 로고
    • Atlantoaxial transarticular screw fixation for a high-riding vertebral artery
    • DOI 10.1097/00007632-200304010-00009
    • Neo M, Matsushita M, Iwashita Y, et al. Atlantoaxial transarticular screw fixation for a high-riding vertebral artery. Spine 2003;28:666-70. (Pubitemid 36397852)
    • (2003) Spine , vol.28 , Issue.7 , pp. 666-670
    • Neo, M.1    Matsushita, M.2    Iwashita, Y.3    Yasuda, T.4    Sakamoto, T.5    Nakamura, T.6
  • 16
    • 0029773340 scopus 로고    scopus 로고
    • The anatomical suitability of the C1-2 complex for transarticular screw fixation
    • Paramore CG, Dickman CA, Sonntag VK. The anatomical suitability of the C1-2 complex for transarticular screw fixation. J Neurosurg 1996;85:221-4. (Pubitemid 26260828)
    • (1996) Journal of Neurosurgery , vol.85 , Issue.2 , pp. 221-224
    • Paramore, C.G.1    Dickman, C.A.2    Sonntag, V.K.H.3
  • 17
    • 33644877567 scopus 로고    scopus 로고
    • A safe screw trajectory for atlantoaxial transarticular fixation achieved using an aiming device
    • Neo M, Sakamoto T, Fujibayashi S, Nakamura T. A safe screw trajectory for atlantoaxial transarticular fixation achieved using an aiming device. Spine 2005;30:E236-42.
    • (2005) Spine , vol.30
    • Neo, M.1    Sakamoto, T.2    Fujibayashi, S.3    Nakamura, T.4
  • 18
    • 33745775283 scopus 로고    scopus 로고
    • Anatomical variations of the V2 segment of the vertebral artery
    • Bruneau M, Cornelius JF, Marneffe V, et al. Anatomical variations of the V2 segment of the vertebral artery. Neurosurgery 2006;59(1 Suppl 1):ONS20-4.
    • (2006) Neurosurgery , vol.59 , Issue.1 SUPPL. 1
    • Bruneau, M.1    Cornelius, J.F.2    Marneffe, V.3
  • 19
    • 41049109242 scopus 로고    scopus 로고
    • Analysis of anatomical variations of bone and vascular structures around the posterior atlantal arch using three-dimensional computed tomography angiography
    • Hong JT, Lee SW, Son BC, et al. Analysis of anatomical variations of bone and vascular structures around the posterior atlantal arch using three-dimensional computed tomography angiography. J Neurosurg Spine 2008;8:230-6.
    • (2008) J Neurosurg Spine , vol.8 , pp. 230-236
    • Hong, J.T.1    Lee, S.W.2    Son, B.C.3
  • 20
    • 27644470637 scopus 로고    scopus 로고
    • Anomalous vertebral artery at the extraosseous and intraosseous regions of the craniovertebral junction: Analysis by three-dimensional computed tomography angiography
    • DOI 10.1097/01.brs.0000184306.19870.a8
    • Yamazaki M, Koda M, Aramomi MA, et al. Anomalous vertebral artery at the extraosseous and intraosseous regions of the craniovertebral junction: analysis by three-dimensional computed tomography angiography. Spine 2005;30:2452-7. (Pubitemid 41567611)
    • (2005) Spine , vol.30 , Issue.21 , pp. 2452-2457
    • Yamazaki, M.1    Koda, M.2    Aramomi, M.-A.3    Hashimoto, M.4    Masaki, Y.5    Okawa, A.6
  • 21
    • 0032532435 scopus 로고    scopus 로고
    • The reliability of the lateral radiograph in determination of the optimal transarticular C1-C2 screw length
    • DOI 10.1097/00007632-199810150-00009
    • Xu R, Ebraheim NA, Misson JR, Yeasting RA. The reliability of lateral radiograph in determination of the optimal transarticular C1-C2 screw length. Spine 1998;23:2190-4. (Pubitemid 28485174)
    • (1998) Spine , vol.23 , Issue.20 , pp. 2190-2194
    • Xu, R.1    Ebraheim, N.A.2    Misson, J.R.3    Yeasting, R.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.