-
2
-
-
0033395146
-
Osseointegration in porous coated knee arthroplasty. The influence of component coating type in sheep
-
Bellemans J. Osseointegration in porous coated knee arthroplasty. The influence of component coating type in sheep. Acta Orthop Scand (Suppl 288) 1999: 1-35.
-
(1999)
Acta Orthop Scand
, Issue.SUPPL. 288
, pp. 1-35
-
-
Bellemans, J.1
-
3
-
-
0032868136
-
Fixation and bearing surfaces for the next millennium
-
Bobyn J D. Fixation and bearing surfaces for the next millennium. Orthopedics 1999; 22 (9): 810-2.
-
(1999)
Orthopedics
, vol.22
, Issue.9
, pp. 810-812
-
-
Bobyn, J.D.1
-
5
-
-
0020178457
-
Effect of pore size on the peel strength of attachment of fibrous tissue to porous-surfaced implants
-
DOI 10.1002/jbm.820160505
-
Bobyn J D, Wilson G J, MacGregor D C, Pilliar R M, Weatherly G C. Effect of pore size on the peel strength of attachment of fibrous tissue to porous-surfaced implants. J Biomed Mater Res 1982; 16 (5): 571-84. (Pubitemid 12009635)
-
(1982)
Journal of Biomedical Materials Research
, vol.16
, Issue.5
, pp. 571-584
-
-
Bobyn, J.D.1
Wilson, G.J.2
MacGregor, D.C.3
-
6
-
-
0032886563
-
Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial
-
DOI 10.1302/0301-620X.81B5.9283
-
Bobyn J D, Stackpool G J, Hacking S A, Tanzer M, Krygier J J. Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial. J Bone Joint Surg (Br) 1999a; 81 (5): 907-14. (Pubitemid 29438375)
-
(1999)
Journal of Bone and Joint Surgery - Series B
, vol.81
, Issue.5
, pp. 907-914
-
-
Bobyn, J.D.1
Stackpool, G.J.2
Hacking, S.A.3
Tanzer, M.4
Krygier, J.J.5
-
7
-
-
0032961169
-
Tissue response to porous tantalum acetabular cups: A canine model
-
DOI 10.1016/S0883-5403(99)90062-1
-
Bobyn J D, Toh K K, Hacking S A, Tanzer M, Krygier J J. Tissue response to porous tantalum acetabular cups: a canine model. J Arthroplasty 1999b; 14 (3): 347-54. (Pubitemid 29172252)
-
(1999)
Journal of Arthroplasty
, vol.14
, Issue.3
, pp. 347-354
-
-
Bobyn, J.D.1
Toh, K.-K.2
Hacking, S.A.3
Tanzer, M.4
Krygier, J.J.5
-
8
-
-
0015648310
-
The effect of movement on the bonding of porous metal to bone
-
Cameron H U, Pilliar R M, Macnab I. The effect of movement on the bonding of porous metal to bone. J Biomed Mater Res 1973; 7(4): 301-11.
-
(1973)
J Biomed Mater Res
, vol.7
, Issue.4
, pp. 301-311
-
-
Cameron, H.U.1
Pilliar, R.M.2
Macnab, I.3
-
10
-
-
0023687068
-
Histologic analysis of retrieved human porous-coated total joint components
-
Cook S D, Thomas K A, Haddad R J, Jr. Histologic analysis of retrieved human porous-coated total joint components. Clin Orthop 1988; (234): 90-101.
-
(1988)
Clin Orthop
, Issue.234
, pp. 90-101
-
-
Cook, S.D.1
Thomas, K.A.2
Haddad Jr., R.J.3
-
11
-
-
0031719730
-
Changes in the stiffness of the human tibial cartilage-bone complex in early-stage osteoarthrosis
-
Ding M, Dalstra M, Linde F, Hvid I. Changes in the stiffness of the human tibial cartilage-bone complex in early-stage osteoarthrosis. Acta Orthop Scand 1998; 69 (4): 358-62. (Pubitemid 28466562)
-
(1998)
Acta Orthopaedica Scandinavica
, vol.69
, Issue.4
, pp. 358-362
-
-
Ding, M.1
Dalstra, M.2
Linde, F.3
Hvid, I.4
-
12
-
-
0036238561
-
Age-related variations in the microstructure of human tibial cancellous bone
-
DOI 10.1016/S0736-0266(01)00132-2, PII S0736026601001322
-
Ding M, Odgaard A, Linde F, Hvid I. Age-related variations in the microstructure of human tibial cancellous bone. J Orthop Res 2002; 20 (3): 615-21. (Pubitemid 34461023)
-
(2002)
Journal of Orthopaedic Research
, vol.20
, Issue.3
, pp. 615-621
-
-
Ding, M.1
Odgaard, A.2
Linde, F.3
Hvid, I.4
-
13
-
-
0043030028
-
Changes in the three-dimensional microstructure of human tibial cancellous bone in early osteoarthritis
-
Ding M, Odgaard A, Hvid I. Changes in the three-dimensional microstructure of human tibial cancellous bone in early osteoarthritis. J Bone Joint Surg (Br) 2003; 85 (6): 906-12. (Pubitemid 36986859)
-
(2003)
Journal of Bone and Joint Surgery - Series B
, vol.85
, Issue.6
, pp. 906-912
-
-
Ding, M.1
Odgaard, A.2
Hvid, I.3
-
14
-
-
67651154710
-
Fixation of a trabecular metal knee arthroplasty component. A prospective randomized study
-
Dunbar M J, Wilson D A, Hennigar A W, Amirault J D, Gross M, Reardon G P. Fixation of a trabecular metal knee arthroplasty component. A prospective randomized study. J Bone Joint Surg (Am) 2009; 91(7): 1578-86.
-
(2009)
J Bone Joint Surg (Am)
, vol.91
, Issue.7
, pp. 1578-1586
-
-
Dunbar, M.J.1
Wilson, D.A.2
Hennigar, A.W.3
Amirault, J.D.4
Gross, M.5
Reardon, G.P.6
-
15
-
-
0035668459
-
Miller-Galante total knee arthroplasty: The importance of material and design on the revision rate
-
DOI 10.1007/s002640100294
-
Effenberger H, Berka J, Hilzensauer G, Ramsauer T, Dorn U, Kisslinger E. Miller-Galante total knee arthroplasty: the importance of material and design on the revision rate. Int Orthop 2001; 25 (6): 378-81. (Pubitemid 34016812)
-
(2001)
International Orthopaedics
, vol.25
, Issue.6
, pp. 378-381
-
-
Effenberger, H.1
Berka, J.2
Hilzensauer, G.3
Ramsauer, T.4
Dorn, U.5
Kisslinger, E.6
-
16
-
-
0014983592
-
Sintered fiber metal composites as a basis for attachment of implants to bone
-
Galante J, Rostoker W, Lueck R, Ray R D. Sintered fiber metal composites as a basis for attachment of implants to bone. J Bone Joint Surg (Am) 1971; 53 (1): 101-14.
-
(1971)
J Bone Joint Surg (Am)
, vol.53
, Issue.1
, pp. 101-114
-
-
Galante, J.1
Rostoker, W.2
Lueck, R.3
Ray, R.D.4
-
17
-
-
0026582767
-
Early migration of prostheses related to long-term survivorship: Comparison of tibial components in knee replacement
-
Grewal R, Rimmer M G, Freeman M A R. Early migration of prostheses related to long-term survivorship: Comparison of tibial components in knee replacement. J Bone Joint Surg (Br) 1992; 74 (2): 239-42.
-
(1992)
J Bone Joint Surg (Br)
, vol.74
, Issue.2
, pp. 239-242
-
-
Grewal, R.1
Rimmer, M.G.2
Freeman, M.A.R.3
-
18
-
-
16244381109
-
Radiographic evaluation of a monoblock acetabular component: A multicenter study with 2- to 5-year results
-
DOI 10.1016/j.arth.2004.12.049
-
Gruen T A, Poggie R A, Lewallen D G, Hanssen A D, Lewis R J, O'Keefe T J, Stulberg S D, Sutherland C J. Radiographic evaluation of a monoblock acetabular component: A multicenter study with 2- to 5-year results. J Arthroplasty 2005; 20 (3): 369-78. (Pubitemid 40460806)
-
(2005)
Journal of Arthroplasty
, vol.20
, Issue.3
, pp. 369-378
-
-
Gruen, T.A.1
Poggie, R.A.2
Lewallen, D.G.3
Hanssen, A.D.4
Lewis, R.J.5
O'Keefe, T.J.6
Stulberg, S.D.7
Sutherland, C.J.8
-
19
-
-
33244465231
-
The premature failure of the Charnley Elite-Plus stem. A confirmation of RSA predictions
-
DOI 10.1302/0301-620X.88B2.17055
-
Hauptfleisch J, Glyn-Jones S, Beard D J, Gill H S, Murray D W. The premature failure of the Charnley Elite-Plus stem: a confirmation of RSA predictions. J Bone Joint Surg (Br) 2006; 88 (2): 179-83. (Pubitemid 43279927)
-
(2006)
Journal of Bone and Joint Surgery - Series B
, vol.88
, Issue.2
, pp. 179-183
-
-
Hauptfleisch, J.1
Glyn-Jones, S.2
Beard, D.J.3
Gill, H.S.4
Murray, D.W.5
-
20
-
-
57149088860
-
A trabecular metal tibial component in total knee replacement in patients younger than 60 years: A two-year radiostereophotogrammetric analysis
-
Henricson A, Linder L, Nilsson K G. A trabecular metal tibial component in total knee replacement in patients younger than 60 years: a two-year radiostereophotogrammetric analysis. J Bone Joint Surg (Br) 2008; 90 (12): 1585-93.
-
(2008)
J Bone Joint Surg (Br)
, vol.90
, Issue.12
, pp. 1585-1593
-
-
Henricson, A.1
Linder, L.2
Nilsson, K.G.3
-
21
-
-
0020617864
-
Preliminary experience with a total knee prosthesis with porous coating used without cement
-
Hungerford D S, Kenna R V. Preliminary experience with a total knee prosthesis with porous coating used without cement. Clin Orthop 1983; (176): 95-107. (Pubitemid 13068411)
-
(1983)
Clinical Orthopaedics and Related Research
, vol.NO. 176
, pp. 95-107
-
-
Hungerford, D.S.1
Kenna, R.V.2
-
23
-
-
0037692766
-
A new model-based RSA method validated using CAD models and models from reversed engineering
-
DOI 10.1016/S0021-9290(03)00002-2
-
Kaptein B L, Valstar E R, Stoel B C, Rozing P M, Reiber J H. A new model-based RSA method validated using CAD models and models from reversed engineering. J Biomech 2003; 36 (6): 873-82. (Pubitemid 36555384)
-
(2003)
Journal of Biomechanics
, vol.36
, Issue.6
, pp. 873-882
-
-
Kaptein, B.L.1
Valstar, E.R.2
Stoel, B.C.3
Rozing, P.M.4
Reiber, J.H.C.5
-
24
-
-
35848947548
-
Clinical validation of model-based RSA for a total knee prosthesis
-
DOI 10.1097/BLO.0b013e3181571aa5, PII 0000308620071100000032
-
Kaptein B L, Valstar E R, Stoel B C, Reiber H C, Nelissen R G. Clinical validation of model-based RSA for a total knee prosthesis. Clin Orthop 2007; (464): 205-9. (Pubitemid 350059968)
-
(2007)
Clinical Orthopaedics and Related Research
, Issue.464
, pp. 205-209
-
-
Kaptein, B.L.1
Valstar, E.R.2
Stoel, B.C.3
Reiber, H.C.4
Nelissen, R.G.5
-
25
-
-
0026350205
-
"Hybrid" total knee arthroplasty with the Miller-Galante prosthesis. A prospective clinical and roentgenographic evaluation
-
Kraay M J, Meyers S A, Goldberg V M, Figgie H E, III, Conroy P A. "Hybrid" total knee arthroplasty with the Miller-Galante prosthesis. A prospective clinical and roentgenographic evaluation. Clin Orthop 1991; (273): 32-41.
-
(1991)
Clin Orthop
, Issue.273
, pp. 32-41
-
-
Kraay, M.J.1
Meyers, S.A.2
Goldberg, V.M.3
Figgie III, H.E.4
Conroy, P.A.5
-
26
-
-
0026336234
-
The role of fixation and bone quality on the mechanical stability of tibial knee components
-
Lee R W, Volz R G, Sheridan D C. The role of fixation and bone quality on the mechanical stability of tibial knee components. Clin Orthop 1991; (273): 177-83.
-
(1991)
Clin Orthop
, Issue.273
, pp. 177-183
-
-
Lee, R.W.1
Volz, R.G.2
Sheridan, D.C.3
-
27
-
-
33744947282
-
Experimental and clinical performance of porous tantalum in orthopedic surgery
-
DOI 10.1016/j.biomaterials.2006.04.041, PII S014296120600439X
-
Levine B R, Sporer S, Poggie R A, Della Valle C J, Jacobs J J. Experimental and clinical performance of porous tantalum in orthopedic surgery. Biomaterials 2006; 27 (27): 4671-81. (Pubitemid 43849977)
-
(2006)
Biomaterials
, vol.27
, Issue.27
, pp. 4671-4681
-
-
Levine, B.R.1
Sporer, S.2
Poggie, R.A.3
Della, V.C.J.4
Jacobs, J.J.5
-
28
-
-
34548611684
-
Porous tantalum in reconstructive surgery of the knee: A review
-
Levine B, Sporer S, la Valle C J, Jacobs J J, Paprosky W. Porous tantalum in reconstructive surgery of the knee: a review. J Knee Surg 2007; 20 (3): 185-94.
-
(2007)
J Knee Surg
, vol.20
, Issue.3
, pp. 185-194
-
-
Levine, B.1
Sporer, S.2
La Valle, C.J.3
Jacobs, J.J.4
Paprosky, W.5
-
29
-
-
34347258917
-
Evolution of Tibial Fixation in Total Knee Arthroplasty
-
DOI 10.1016/j.arth.2007.02.006, PII S088354030700099X
-
Lombardi A V, Jr., Berasi C C, Berend K R. Evolution of tibial fixation in total knee arthroplasty. J Arthroplasty (Suppl 1) 2007; 22 (4): 25-9. (Pubitemid 47001310)
-
(2007)
Journal of Arthroplasty
, vol.22
, Issue.4 SUPPL.
, pp. 25-29
-
-
Lombardi Jr., A.V.1
Berasi, C.C.2
Berend, K.R.3
-
30
-
-
67650708864
-
Eight- to ten-year clinical and radiographic outcome of a porous tantalum monoblock acetabular component
-
Macheras G, Kateros K, Kostakos A, Koutsostathis S, Danomaras D, Papagelopoulos P J. Eight- to ten-year clinical and radiographic outcome of a porous tantalum monoblock acetabular component. J Arthroplasty 2009; 24 (5): 705-9.
-
(2009)
J Arthroplasty
, vol.24
, Issue.5
, pp. 705-709
-
-
Macheras, G.1
Kateros, K.2
Kostakos, A.3
Koutsostathis, S.4
Danomaras, D.5
Papagelopoulos, P.J.6
-
31
-
-
0025986872
-
Evaluation of micromotion in cemented vs uncemented knee arthroplasty in osteoarthrosis and rheumatoid arthritis. Randomized study using roentgen stereophotogrammetric analysis
-
Nilsson K G, Karrholm J, Ekelund L, Magnusson P. Evaluation of micromotion in cemented vs uncemented knee arthroplasty in osteoarthrosis and rheumatoid arthritis. Randomized study using roentgen stereophotogrammetric analysis. J Arthroplasty 1991; 6 (3): 265-78.
-
(1991)
J Arthroplasty
, vol.6
, Issue.3
, pp. 265-278
-
-
Nilsson, K.G.1
Karrholm, J.2
Ekelund, L.3
Magnusson, P.4
-
32
-
-
0031972219
-
Hydroxyapatite augmentation of the porous coating improves fixation of tibial components
-
Onsten I, Nordqvist A, Carlsson A S, Besjakov J, Shott S. Hydroxyapatite augmentation of the porous coating improves fixation of tibial components. J Bone Joint Surg (Br) 1998; 80 (3): 417-25.
-
(1998)
J Bone Joint Surg (Br)
, vol.80
, Issue.3
, pp. 417-425
-
-
Onsten, I.1
Nordqvist, A.2
Carlsson, A.S.3
Besjakov, J.4
Shott, S.5
-
33
-
-
0032201263
-
The Coventry Award. Modular tibial insert micromotion. A concern with contemporary knee implants
-
Parks N L, Engh G A, Topoleski L D, Emperado J. The Coventry Award. Modular tibial insert micromotion. A concern with contemporary knee implants. Clin Orthop 1998; (356): 10-5.
-
(1998)
Clin Orthop
, Issue.356
, pp. 10-15
-
-
Parks, N.L.1
Engh, G.A.2
Topoleski, L.D.3
Emperado, J.4
-
34
-
-
0033666123
-
Sealing effect of hydroxyapatite coating: A 12-month study in canines
-
Rahbek O, Overgaard S, Jensen T B, Bendix K, Soballe K. Sealing effect of hydroxyapatite coating: a 12-month study in canines. Acta Orthop Scand 2000; 71 (6): 563-73.
-
(2000)
Acta Orthop Scand
, vol.71
, Issue.6
, pp. 563-573
-
-
Rahbek, O.1
Overgaard, S.2
Jensen, T.B.3
Bendix, K.4
Soballe, K.5
-
35
-
-
28244483268
-
Particle migration and gap healing around trabecular metal implants
-
DOI 10.1007/s00264-005-0008-4
-
Rahbek O, Kold S, Zippor B, Overgaard S, Soballe K. Particle migration and gap healing around trabecular metal implants. Int Orthop 2005a; 29 (6): 368-74. (Pubitemid 41712823)
-
(2005)
International Orthopaedics
, vol.29
, Issue.6
, pp. 368-374
-
-
Rahbek, O.1
Kold, S.2
Zippor, B.3
Overgaard, S.4
Soballe, K.5
-
36
-
-
14844321882
-
The influence of surface porosity on gap-healing around intra-articular implants in the presence of migrating particles
-
DOI 10.1016/j.biomaterials.2004.11.058, PII S014296120401107X
-
Rahbek O, Kold S, Zippor B, Overgaard S, Soballe K. The influence of surface porosity on gap-healing around intra-articular implants in the presence of migrating particles. Biomaterials 2005b; 26 (23): 4728-36. (Pubitemid 40343021)
-
(2005)
Biomaterials
, vol.26
, Issue.23
, pp. 4728-4736
-
-
Rahbek, O.1
Kold, S.2
Zippor, B.3
Overgaard, S.4
Soballe, K.5
-
37
-
-
0036799675
-
Tibial interface wear in retrieved total knee components and correlations with modular insert motion
-
Rao A R, Engh G A, Collier M B, Lounici S. Tibial interface wear in retrieved total knee components and correlations with modular insert motion. J Bone Joint Surg (Am) 2002; 84 (10): 1849-55. (Pubitemid 35176480)
-
(2002)
Journal of Bone and Joint Surgery - Series A
, vol.84
, Issue.10
, pp. 1849-1855
-
-
Rao, A.R.1
Engh, G.A.2
Collier, M.B.3
Lounici, S.4
-
38
-
-
0034762231
-
The Swedish Knee Arthroplasty Register 1975-1997: An update with special emphasis on 41,223 knees operated on in 1988-1997
-
Robertsson O, Knutson K, Lewold S, Lidgren L. The Swedish Knee Arthroplasty Register 1975-1997: an update with special emphasis on 41,223 knees operated on in 1988-1997. Acta Orthop Scand 2001; 72 (5): 503-13.
-
(2001)
Acta Orthop Scand
, vol.72
, Issue.5
, pp. 503-513
-
-
Robertsson, O.1
Knutson, K.2
Lewold, S.3
Lidgren, L.4
-
39
-
-
0027370573
-
Micromotion of a noncemented tibial component with screw fixation: An in vivo roentgen stereophotogrammetric study of the Miller-Galante prosthesis
-
Ryd L, Carlsson L, Herberts P. Micromotion of a noncemented tibial component with screw fixation: An in vivo roentgen stereophotogrammetric study of the Miller-Galante prosthesis. Clin Orthop 1993; (295): 218-25. (Pubitemid 23299654)
-
(1993)
Clinical Orthopaedics and Related Research
, Issue.295
, pp. 218-225
-
-
Ryd, L.1
Carlsson, L.2
Herberts, P.3
-
40
-
-
0029056371
-
Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses
-
Ryd L, Albrektsson B E, Carlsson L, Dansgard F, Herberts P, Lindstrand A, Regner L, Toksvig-Larsen S. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses. J Bone Joint Surg (Br) 1995; 77 (3): 377-83.
-
(1995)
J Bone Joint Surg (Br)
, vol.77
, Issue.3
, pp. 377-383
-
-
Ryd, L.1
Albrektsson, B.E.2
Carlsson, L.3
Dansgard, F.4
Herberts, P.5
Lindstrand, A.6
Regner, L.7
Toksvig-Larsen, S.8
-
41
-
-
0024388994
-
Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system
-
Selvik G. Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. Acta Orthop Scand (Suppl 232) 1989: 1-51.
-
(1989)
Acta Orthop Scand
, Issue.SUPPL. 232
, pp. 1-51
-
-
Selvik, G.1
-
42
-
-
0026832935
-
Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions
-
Soballe K, Hansen E S, Rasmussen H, Jorgensen P H, Bunger C. Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res 1992; 10 (2): 285-99.
-
(1992)
J Orthop Res
, vol.10
, Issue.2
, pp. 285-299
-
-
Soballe, K.1
Hansen, E.S.2
Rasmussen, H.3
Jorgensen, P.H.4
Bunger, C.5
-
43
-
-
0026034033
-
A new model to assess tibial fixation. II. Concurrent histologic and biomechanical observations
-
Stulberg B N, Watson J T, Stulberg S D, Bauer T W, Manley M T. A new model to assess tibial fixation. II. Concurrent histologic and biomechanical observations. Clin Orthop 1991; (263): 303-9.
-
(1991)
Clin Orthop
, Issue.263
, pp. 303-309
-
-
Stulberg, B.N.1
Watson, J.T.2
Stulberg, S.D.3
Bauer, T.W.4
Manley, M.T.5
-
44
-
-
0028567064
-
Effect of pegs and screws on bone ingrowth in cementless total knee arthroplasty
-
Sumner D R, Turner T M, Dawson D, Rosenberg A G, Urban R M, Galante J O. Effect of pegs and screws on bone ingrowth in cementless total knee arthroplasty. Clin Orthop 1994; (309): 150-5.
-
(1994)
Clin Orthop
, Issue.309
, pp. 150-155
-
-
Sumner, D.R.1
Turner, T.M.2
Dawson, D.3
Rosenberg, A.G.4
Urban, R.M.5
Galante, J.O.6
-
45
-
-
0028929906
-
Bone ingrowth and wear debris in well-fixed cementless porous-coated tibial components removed from patients
-
Sumner D R, Kienapfel H, Jacobs J J, Urban R M, Turner T M, Galante J O. Bone ingrowth and wear debris in well-fixed cementless porous-coated tibial components removed from patients. J Arthroplasty 1995; 10 (2): 157-67.
-
(1995)
J Arthroplasty
, vol.10
, Issue.2
, pp. 157-167
-
-
Sumner, D.R.1
Kienapfel, H.2
Jacobs, J.J.3
Urban, R.M.4
Turner, T.M.5
Galante, J.O.6
-
46
-
-
33745457833
-
Biomechanical analysis of the shear behaviour adjacent to an axially loaded implant
-
DOI 10.1016/j.jbiomech.2005.05.027, PII S0021929005002538
-
Swider P, Pedrono A, Mouzin O, Soballe K, Bechtold J E. Biomechanical analysis of the shear behaviour adjacent to an axially loaded implant. J Biomech 2006; 39 (10): 1873-82. (Pubitemid 43949577)
-
(2006)
Journal of Biomechanics
, vol.39
, Issue.10
, pp. 1873-1882
-
-
Swider, P.1
Pedrono, A.2
Mouzin, O.3
Soballe, K.4
Bechtold, J.E.5
-
47
-
-
0026034576
-
Surface flatness after bone cutting. A cadaver study of tibial condyles
-
Toksvig-Larsen S, Ryd L. Surface flatness after bone cutting. A cadaver study of tibial condyles. Acta Orthop Scand 1991; 62 (1): 15-8.
-
(1991)
Acta Orthop Scand
, vol.62
, Issue.1
, pp. 15-18
-
-
Toksvig-Larsen, S.1
Ryd, L.2
-
48
-
-
0025082453
-
An internally cooled saw blade for bone cuts. Lower temperatures in 30 knee arthroplasties
-
Toksvig-Larsen S, Ryd L, Lindstrand A. An internally cooled saw blade for bone cuts. Lower temperatures in 30 knee arthroplasties. Acta Orthop Scand 1990; 61 (4): 321-3.
-
(1990)
Acta Orthop Scand
, vol.61
, Issue.4
, pp. 321-323
-
-
Toksvig-Larsen, S.1
Ryd, L.2
Lindstrand, A.3
-
49
-
-
24144447269
-
Guidelines for standardization of radiostereometry (RSA) of implants
-
DOI 10.1080/17453670510041574
-
Valstar E R, Gill R, Ryd L, Flivik G, Borlin N, Karrholm J. Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 2005; 76 (4): 563-72. (Pubitemid 41232789)
-
(2005)
Acta Orthopaedica
, vol.76
, Issue.4
, pp. 563-572
-
-
Valstar, E.R.1
Gill, R.2
Ryd, L.3
Flivik, G.4
Borlin, N.5
Karrholm, J.6
|